    FLUKE 317 True RMS Clamp Meter 40A

    # 317

    • Unique 40A high-precision low current measurement–0.01A high-resolution, 1.6% high-precision measurement
    • The clamps are slim, lightweight, and portable, making them ideal for use in small, confined spaces
    • Unique 40A high-precision low current measurement–0.01A high-resolution, 1.6% high-precision measurement
    • The clamps are slim, lightweight, and portable, making them ideal for use in small, confined spaces
    • The large backlight display facilitates readings in dark environments
    • Current frequency measurement
    • Precision down to 0.01A and 0.1V
    • 1000A/600A AC/DC current measurement (319/317)
    • 600V AC/DC voltage measurement
    • 4000? resistance measurement
    • Continuity beeper
    • Auto off function enhances battery life, meaning the instrument can work when you need it screen store ‘hold’ function for capturing a measurement result on the screen
    • One year warranty
    General specifications
    Digital display6000 count resolution
    Low battery IndicationDisplays a signal when the batteries are below their required voltage
    Power sourceThree AAA IEC LR03 batteries
    Clamp opening size1.45 in (37 mm)
    Jaw diameter1.45 in (37 mm)
    Dimensions (L x W x H)6.39 x 2.29 x 1.20 in
    (162.4 x 58.25 x 30.5 mm)
    WeightApproximately 13.5 oz (384 g) (batteries included)
    Auto rangeAvailable in Ohms
    SafetyCE
    EN/IEC 61010-1 and IEC 61010-2-032
    Measurement Category: 600V CAT III
    317 Electrical specifications
    Current ACRange40.00 A, 600.0 A
    Resolution0.01 A, 0.1 A
    Accuracy1.6% ±6 digit (50-60 Hz) {40 A}
    2.5% ±8 digit (60-500 Hz) {40 A}
    1.5% ±5 digit (50-60 Hz) {600 A}
    2.5% ±5 digit (60-500 Hz) {600 A}
    Crest Factor add 2% into spec for CF > 23.0 Max @ 500 A, 2.5 Max @ 600 A
    AC responserms
    Current DCRange40.00 A, 600.0 A
    Resolution0.01 A, 0.1 A
    Accuracy1.6% ±6 digit (40 A)
    1.5% ±5 digit (600 A)
    Voltage ACRange600.0 V
    Resolution0.1 V
    Accuracy1.5% ±5 digit (20-500Hz)
    AC responserms
    Voltage DCRange600.0 V
    Resolution0.1 V
    Accuracy1% ±4 digit
    ResistanceRange400.0 Ω, 4000 Ω
    Resolution0.1 Ω, 1 Ω
    Accuracy1% ±5 digit
    Continuity≤ 30 Ω
    InrushIntegration timeN/A
    FrequencyRangeN/A
    AccuracyN/A
    Trigger LevelN/A
    319 Electrical specifications
    Current ACRange40.00 A, 600.0 A, 1000 A
    Resolution0.01 A, 0.1 A, 1 A
    Accuracy1.6% ±6 digit (50-60 Hz) {40 A}
    2.5% ±8 digit (60-500 Hz) {40 A}
    1.5% ±5 digit (50-60 Hz) {600/1000 A}
    2.5% ±5 digit (60-500 Hz) {600/1000 A}
    Crest Factor add 2% into spec for CF > 23.0 Max @ 500 A, 2.5 Max @ 600 A, 1.4 Max @ 1000 A
    AC responserms
    Current DCRange40.00 A, 600.0 A, 1000 A
    Resolution0.01 A, 0.1 A, 1 A
    Accuracy1.6% ±6 digit (40 A)
    1.5% ±5 digit (600/1000 A)
    Voltage ACRange600.0 V
    Resolution0.1 V
    Accuracy1.5% ±5 digit (20-500Hz)
    AC responserms
    Voltage DCRange600.0 V
    Resolution0.1 V
    Accuracy1% ±4 digit
    ResistanceRange400.0 Ω
    4000 Ω
    Resolution0.1 Ω
    1 Ω
    Accuracy1% ±5 digit
    Continuity≤ 30 Ω
    InrushIntegration time100 ms
    FrequencyRange5.0 – 500.0 Hz
    Accuracy0.5% ±5 digit
    Trigger Level10 – 100 Hz ≥ 5 A, 5 – 10 Hz, 100 – 500 Hz ≥ 10 A
    The accuracy specifications aply at 73 °F ±41 °F (23 °C ±5 °C)
    Below 64 °F and above 82 °F (18 °C and above 28 °C) accuracy degrades at (0.1) times specification per °C.
    True rms for ac V and ac A accuracy is specified from 5% to 100% of range.
    Environmental specifications
    Operating temperature14°F to 122°F (-10 °C to 50 °C)
    Storage temperature-40 °F to 140 °F (-40 °C to 60 °C)
    Operating humidityNon-condensing (< 50 °F) (< 10 °C)
    90% RH (50 °F to 86 °F) (10 °C to 30 °C)
    75% RH (86 °F to 104 °F) (30 °C to 40 °C)
    45% RH (104 °F to 122 °F) (40 °C to 50 °C)
    (Without condensation)
    Operating altitude1 mile (2000 meters) above mean sea level
    Storage altitude7 miles (12,000 meters) above mean sea level
    IP RatingIP40
    Vibration requirementsRandom MIL-PRF-28800F Class 2, 5-500 Hz, 30 minutes per axis
    Drop test requirements3 ft (1 m) drop test, six sides, oak floor
    EMI, RFI, EMCInstrument unspecified for use in EMC field ≥ 0.1 V/m
    Temperature coefficients0.1x (specified accuracy)/ °C
    (<64 °F or > 82° F)
    (<18 °C or > 28 °C)
    • Test Leads
    • Soft Carrying Case
    • Three AAA batteries (Installed)
    • 317/319 User Manual

    Provide us your contact detailsone of our product experts will contact you to discuss your needs or schedule a demonstration at a time that suits

    Product selected: Model #







      *Demonstrations can only be scheduled within the UAE

      Sign up to stay in the know-how of our latest products, updates, special offers, and more.