    PCE Instruments PCM 3 Single-Phase Clamp Meter AC 1000 A

    # PCM 3

    • With the digital multimeter AC currents of up to 1000 A AC can be measured easily. At the same time, voltages of up to 1000V AC / DC can be measured with the digital multimeter. Thus, with the power current clamp, apparent power, reactive power and active power measurements up to 750 KW are possible.
    • Another function of the digital multimeter is the measurement of the inrush current. Many consumers have a tremendously high current at the moment of switch-on. With a conventional digital multimeter such a measurement is not possible. For the digital multimeter this is not a problem.
    • With the NCV (Not Connected Voltage) function of the digital multimeter, it can be checked whether a voltage is applied to a line without performing a contacting measurement. This makes the work much easier for the user thanks to the digital multimeter.
    • With the digital multimeter AC currents of up to 1000 A AC can be measured easily. At the same time, voltages of up to 1000V AC / DC can be measured with the digital multimeter. Thus, with the power current clamp, apparent power, reactive power and active power measurements up to 750 KW are possible. Another function of the digital multimeter is the measurement of the inrush current. Many consumers have a tremendously high current at the moment of switch-on. With a conventional digital multimeter such a measurement is not possible. For the digital multimeter this is not a problem.
    • With the NCV (Not Connected Voltage) function of the digital multimeter, it can be checked whether a voltage is applied to a line without performing a contacting measurement. This makes the work much easier for the user thanks to the digital multimeter. In addition to the measuring function, the digital multimeter can also be connected to a terminal via the Bluetooth interface. Via this Bluetooth interface, the measured data can be transmitted directly from the digital multimeter to the terminal, where it can be logged, analyzed and sent.
    • Apparent / active / reactive power
    • Measurement up to the 20th harmonic
    • “Not Connected Voltage” function
    • Inrush current measurement
    • Current measurement up to 1000 A AC
    • Bluetooth interface
    Measuring function
    Current measurement AC
    Measuring rangeResolutionAccuracy
    60 A0.01 A± 2% + 8 Dgt
    600 A0.1 A± 2% + 8 Dgt
    1000 A1 A± 2% + 8 Dgt
    Maximum input current: 1000 A AC
    Frequency range: 40 …. 400 Hz
    Measuring function
    Inrush current AC
    Measuring rangeResolutionAccuracy
    60 A0.01 AFor reference only
    600 A0.1 A± 5% + 60 Dgt
    1000 A1 A± 5% + 60 Dgt
    Integral time: 100 ms
    Measuring range: 20 … 1000 A
    Frequency range: 40 …. 400 Hz
    Measuring function
    Voltage measurement DC
    Measuring rangeResolutionAccuracy
    6V0.001V± 0.5% + 5 Dgt
    60V0.01V± 0.5% + 5 Dgt
    600V0.1V± 0.5% + 5 Dgt
    1000V1V± 0.8% + 4 Dgt
    Input impedance: 10 MΩ
    Maximum input voltage: 750V AC (rms value) or 1000V DC
    Measuring function
    Voltage measurement AC
    Measuring rangeResolutionAccuracy
    6V0.001V± 0.6% + 4 Dgt
    60V0.01V± 0.6% + 4 Dgt
    600V0.1V± 0.6% + 4 Dgt
    1000V1V± 0.8% + 4 Dgt
    Input impedance: 10 MΩ
    Maximum input voltage: 750V AC (rms value) or 1000V DC
    Frequency range: 40 … 400 Hz
    Measuring function
    Frequency measurement with
    The current measuring function
    Measuring rangeResolutionAccuracy
    99.99 Hz0.01 Hz± 1.5% + 5 Dgt
    999.9 Hz0.1 Hz± 1.5% + 5 Dgt
    Measuring range: 10 … 1 kHz
    Measuring range of the input signal: > 20 AAC (rms value)
    The input current increases with the measuring frequency.
    Maximum input current: 1000 AAC (rms value)
    Measuring function
    Frequency measurement with the
    Voltage measurement function
    Measuring rangeResolutionAccuracy
    99.99 Hz0.01 Hz± 1.5% + 5 Dgt
    999.9 Hz0.1 Hz± 1.5% + 5 Dgt
    9,999 kHz0.001 kHz± 1.5% + 5 Dgt
    Measuring range: 10 … 10 kHz
    Measuring range of the input signal: > 1V AC (rms value)
    The input current increases with the measuring frequency.
    Maximum input voltage: 1000V AC (rms value)
    Measuring function
    Frequency measurement 
    Measuring rangeResolutionAccuracy
    9,999 Hz0.001 Hz± 0.3% + 5 Dgt
    99.99 Hz0.01 Hz± 0.3% + 5 Dgt
    9,999 kHz0.1 Hz± 0.3% + 5 Dgt
    999.9 Hz0.001 kHz± 0.3% + 5 Dgt
    99.99 kHz0.01 kHz± 0.3% + 5 Dgt
    999.9 kHz0.1 kHz± 0.3% + 5 Dgt
    9,999 MHz0.001 MHz± 0.3% + 5 Dgt
    Overvoltage protection: 1000V DC or 750V AC (rms value)
    Range of voltage input> 2V
    (as the input voltage increases, so does the frequency)
    Measuring function
    Duty cycle
    Measuring rangeResolutionAccuracy
    0.1 … 99.9%0.1%± 0.3% + 5 Dgt
    Frequency range: 10 … 10 kHz
    Voltage range: 2 … 250V AC (rms value)
    (The voltage increases with the frequency)
    Duty cycle with theFrequency range: 10 … 1 kHz
    Current measurement functionInput current: 20 … 1000 AAC (rms value)
    Duty cycle with theFrequency range: 10 … 1 kHz
    Voltage measurement functionInput current: 1 … 750V AC (rms value)
    Input impedance: 1MΩ
    Measuring function
    Resistivity
    Measuring rangeResolutionAccuracy
    600 Ω0.1 Ω± 0.8% + 3 Dgt
    6 kΩ0.001 kΩ± 0.8% + 3 Dgt
    60 kΩ0.01 kΩ± 0.8% + 3 Dgt
    600 kΩ0.1 kΩ± 0.8% + 3 Dgt
    6 MΩ0.001 MΩ± 2% + 5 Dgt
    60 MΩ0.1 MΩ± 2% + 5 Dgt
    Measuring voltage: approx. 0.78V
    Overvoltage protection: 750V DC, 1000V AC (rms value)
    Measuring function
    Continuity test
    Measuring rangeResolutionAccuracy
    600 Ω0.1 Ω
    Acoustic signal at < 50 Ω
    Test voltage: 1.48V
    Overvoltage protection: 750V DC, 1000V AC (rms value)
    Measuring function
    Capacitance measurement
    Measuring rangeResolutionAccuracy
    9.999 nF0.001 nF± 3% + 5 Dgt
    99.99 n.f.0.01 nF± 3% + 5 Dgt
    999.9 nF0.1 nF± 3% + 5 Dgt
    9.999 μF0.001 μF± 3% + 5 Dgt
    99.99 μF0.01 μF± 3% + 5 Dgt
    999.9 μF0.1 μF± 3% + 5 Dgt
    9,999mF0.001 mF± 3% + 5 Dgt
    99.99 mF0.01 mF± 3% + 5 Dgt
    Overvoltage protection: 750V DC, 1000V AC (rms value)
    Measuring function
    Diode measurement
    Measuring rangeResolutionAccuracy
    3V 0.001V
    DC anode side: approx. 1-mA
    DC cathode side: approx. 3.2V
    Overvoltage protection: 750V DC, 1000V AC (rms value)
    Measuring function
    Single phase power measurement
    Measuring rangeResolutionAccuracy
    3 W / VA / Var0.01 W / VA / Var± 3% + 5 Dgt
    100 W / VA / Var0.1 W / VA / Var± 3% + 5 Dgt
    4000 W / VA / Var1 W / VA / Var± 3% + 5 Dgt
    10 kW / VA / var0.01 kW / VA / Var± 3% + 5 Dgt
    100 kW / VA / var0.1 kW / VA / Var± 3% + 5 Dgt
    750 kW / VA / var1 kW / VA / Var± 3% + 5 Dgt
    Smallest measuring current: 1-mA
    Smallest measuring voltage: 1V
    Measuring function
    Power factor capacitive / inductive
    Measuring rangeResolutionAccuracy
    0.1 … 10.001± 5% + 5 Dgt
    Smallest measuring current: 1-mA
    Smallest measuring voltage: 1V
    Measuring function
    Harmonics measurement
    Measuring rangeResolutionAccuracy
    1± 3% + 10 Dgt
    2 … 6± 3.5% + 10 Dgt
    7 … 8± 4.5% + 10 Dgt
    9 … 10± 5% + 10 Dgt
    11 … 15± 7% + 10 Dgt
    16 … 20± 10% + 10 Dgt
    Smallest measuring current: 1-mA
    Smallest measuring voltage: 1V
    The resolution depends on the voltage measuring range
    General specifications
    Measuring rangeAutomatically and manually adjustable
    Maximum voltage range1000V DC or 750V AC
    Maximum working height2000 m / 6561 ft
    DisplayLCD
    Maximum display5999 Dgt.
    Overrange“OIL”
    Measuring range underflow“-OL”
    Measuring rate3 Hz
    Automatic shutdownAfter 30 minutes
    Power supply9V block battery
    Battery indicatorIcon if the battery voltage is too low
    Temperature coefficient0.1 x accuracy x °C / °F*
    Operating conditions0 … 40°C, 32 … 104°F
    Storage conditions-10 … 60°C, 14 … 140°F
    Dimensions238 x 92 x 50 mm / 9.4 x 3.6 x 2 in  
    WeightAbout 420 g / < 1 lb (with batteries)
    Accuracies are given at ambient conditions of 18 … 28°C / 65 … 83°F.
    *The temperature is the difference between the temperature of the operating conditions and the current ambient temperature.
    • 1 x Voltmeter PCE-PCM 3
    • 1 x Transport bag
    • 1 x Test lead set
    • 1 x 9V block battery
    • 1 x User manual