• Store Locator
  • Schedule a
    Demo
  • Add products to your Toolbox to save it for requesting a quote while you keep browsing for other products to complete your list.

    My
    Toolbox
  • Create a Requisition

    FLUKE 123B-EU Industrial ScopeMeter (20 MHz)

    # 123B-EU

    • Dual Input Multimeter and Recorder; 20 MHz
    • Portable; handheld oscilloscope
    • Max 20MHZ bandwidth

    Simplified testing, more insight and faster electro-mechanical troubleshooting

     

    The compact ScopeMeter® 120B Series, is the rugged oscilloscope solution for industrial electrical and electro-mechanical equipment troubleshooting and maintenance applications. It’s a truly integrated test tool, with oscilloscope, multimeter and high-speed recorder in one easy-to-use instrument. The ScopeMeter 120B Series also integrates with Fluke Connect® mobile app and FlukeView® for ScopeMeter software to enable further collaboration, data analysis and archiving of critical test information.

    *Not all models are available in all countries. Check with your local Fluke representative.

     

    Other useful features:

     

    • Features two 5,000-count True-RMS digital multimeters
    • Offers recorder Event Detect to capture elusive intermittent signals on repetitive waveforms up to 4 kHz
    • Comes with shielded test leads for oscilloscope, resistance and continuity measurements
    • Features resistance, continuity, diode, and capacitance meter measurements
    • Performs power measurements (W, VA, VAR, PF, DPF, Hz)
    • Measures voltage, current and power harmonics
    • Check Industrial networks with BusHealth physical layer tests against defined reference levels (125B only)
    • Allows you to save and recall data and instrument setups
    • Includes FlukeView® ScopeMeter® software for Windows®
    • Features a rugged design to withstand 3g vibration, 30g shock, and rated IP51 according to EN/IEC60529
    • Runs on a Li-Ion rechargeable battery providing seven-hours operation (with four-hour charge time)
    • Features highest safety rating in the industry: safety rated for CAT IV 600 V
    Oscilloscope mode
    Vertical
    Frequency response – dc coupledWithout probes and test leads (with BB120)123B: dc to 20 MHz (-3 dB)
    124B and 125B: dc to 40 MHz (-3 dB)
    With STL120-IV 1:1 shielded test leadsDC to 12.5 MHz (-3 dB) / dc to 20 MHz (-6 dB)
    With VP41 10:1 Probe123B: dc to 20MHz (-3 dB)
    124B and 125B: dc to 40 MHz (-3 dB)
    Frequency response – ac coupled (lf roll off)Without probes and test leads<10 Hz (-3 dB)
    With STL120-IV 1:1 shielded test leads<10 Hz (-3 dB)
    With VP41 10:1 Probe<10 Hz (-3 dB)
    Rise time, excluding probes,
    test leads
    123B <17.5 ns
    124B and 125B <8.75 ns
    Input impedanceWithout probes and test leads1 MΩ//20 pF
    With BB1201 MΩ//24 pF
    With STL120-IV 1:1 shielded test leads1 MΩ//230 pF
    With VP41 10:1 Probe5 MΩ//15.5 pF
    Sensitivity5 mV to 200 V/div
    Analog bandwidth limiter10 kHz
    Display modesA, -A, B, -B
    Max. input voltage A and BDirect, with test leads, or with VP41 Probe600 Vrms Cat IV, 750 Vrms maximum voltage.
    With BB120600 Vrms
    Max. floating voltage, from any terminal to ground600 Vrms Cat IV, 750 Vrms up to 400Hz
    Horizontal
    Scope modesNormal, Single, Roll
    Ranges (normal)Equivalent sampling123B: 20 ns to 500 ns/div,
    124B and 125B: 10 ns to 500 ns/div
    Real time sampling1 μs to 5 s/div
    Single (real time)1 μs to 5 s/div
    Roll (real time)1s to 60 s/div
    Sampling rate (for both channels simultaneously)Equivalent sampling (repetitive signals)Up to 4 GS/s
    Real time sampling 1 μs to 60 s/div40 MS/s

     

    Trigger
    Screen updateFree run, on trigger
    SourceA, B
    Sensitivity A and B@ DC to 5 MHz0.5 divisions or 5 mV
    @ 40 MHz123B: 4 divisions
    124B and 125B: 1.5 divisions
    @ 60 MHz123B: N/A
    124B and 125B: 4 divisions
    SlopePositive, negative

     

    Advanced scope functions
    Display modesNormalCaptures up to 25 ns glitches and displays analog-like persistence waveform
    SmoothSuppresses noise from a waveform
    Glitch offDoes not capture glitches between samples
    EnvelopeRecords and displays the minimum and maximum of waveforms over time
    Auto set (Connect-and-View™)Continuous fully automatic adjustments of amplitude, time base, trigger levels, trigger gap, and hold-off. Manual override by user adjustment of amplitude, time base, or trigger level.

     

    Dual input meter
    The accuracy of all measurements is within ±(% of reading + number of counts) from 18 °C to 28 °C.
    Add 0.1x (specific accuracy) for each °C below 18 °C or above 28 °C. For voltage measurements with 10:1 probe, add probe  uncertainty +1%. More than one waveform period must be visible on the screen.

     

    Input A and input B
    DC voltage (VDC)
    Ranges500 mV, 5 V, 50 V, 500 V, 750 V
    Accuracy±(0.5% +5 counts)
    Common mode rejection (CMRR)>100 dB @ dc, >60 dB @ 50, 60, or 400 Hz
    Full scale reading5000 counts
    True-rms voltages (V ac and V ac+dc)
    Ranges500 mV, 5 V, 50 V, 500 V, 750 V
    Accuracy for 5% to 100% of range (DC coupled)DC to 60 Hz (V ac+dc)±(1% +10 counts)
    1 Hz to 60 Hz (V ac)±(1% +10 counts)
    Accuracy for 5% to 100% of range (AC or dc coupled)60 Hz to 20 kHz±(2.5% +15 counts)
    DC rejection (only VAC)>50 dB
    Common mode rejection (CMRR)>100 dB @ dc
    >60 dB @ 50, 60, or 400 Hz
    Full scale reading5000 counts, reading is independent of any signal crest factor.
    Peak
    ModesMax peak, Min peak, or pk-to-pk
    Ranges500 mV, 5 V, 50 V, 500 V, 2200 V
    AccuracyAccuracy Max peak or Min peak5% of full scale
    Accuracy Peak-to-Peak10% of full scale
    Full scale reading500 counts
    Frequency (Hz)
    Ranges123B: 1 Hz, 10 Hz, 100 Hz, 1 kHz, 10 kHz, 100 kHz,1 MHz, 10 MHz, and 50 MHz
    124B and 125B: 1 Hz, 10 Hz, 100 Hz, 1 kHz, 10 kHz, 100 kHz, 1 MHz, 10 MHz, and 70 MHz
    Frequency range15 Hz (1 Hz) to 50 MHz in continuous autoset
    Accuracy @1 Hz to 1 MHz±(0.5% +2 counts)
    Full scale reading10,000 counts
    RPM
    Max reading50.00 kRPM
    Accuracy±(0.5% +2 counts)
    Duty cycle (PULSE)
    Range2% to 98%
    Frequency range15 Hz (1 Hz) to 30 MHz in continuous autoset
    Pulse width (PULSE)
    Frequency range15 Hz (1 Hz) to 30 MHz in continuous autoset
    Full scale reading1000 counts
    Amperes (AMP)
    With current clampRangesSame as V dc, V ac, V ac+dc, or PEAK
    Scale factors0.1 mV/A, 1 mV/A, 10 mV/A, 100 mV/A, 400 mV/A, 1 V/A, 10 mV/mA
    AccuracySame as V dc, V ac, V ac+dc, or PEAK (add current clamp uncertainty)
    Temperature (TEMP) with optional temperature probe
    Range200 °C/div (200 °F/div)
    Scale factor1 mV/°C and 1 mV/°F
    AccuracyAs V dc (add temp. probe uncertainty)
    Decibel (dB)
    0 dBV1 V
    0 dBm (600 Ω /50 Ω)1 mW referenced to 600 Ω or 50 Ω
    dB onV dc, V ac, or Vac+dc
    Full scale reading1000 counts
    Crest factor (CREST)
    Range1 to 10
    Full scale reading90 Counts
    Phase
    ModesA to B, B to A
    Range0 to 359 degrees
    Resolution1 degree
    Power (125B only)
    Configurations1 phase / 3 phase 3 conductor balanced loads (3 phase: fundamental component only, AUTOSET mode only)
    Power factor (PF)Ratio between watts and VA range – 0.00 to 1.00
    WattRMS reading of multiplying corresponding samples of input A (volts) and input B (amperes)
    Full scale reading999 counts
    VAVrms x Arms
    Full scale reading999 counts
    VA reactive (var)√((VA)2-W2)
    Full scale reading999 counts
    Vpwm
    PurposeTo measure on pulse width modulated signals, like motor drive inverter outputs
    PrincipleReadings show the effective voltage based on the average value of samples over a whole number of periods of the fundamental frequency
    AccuracyAs Vrms for sinewave signals

     

    Input A to common
    Ohm (Ω)
    Ranges123B and 124B500 Ω , 5 kΩ, 50 kΩ, 500 kΩ, 5 MΩ, 30 MΩ
    125B50 Ω, 500 Ω , 5 kΩ, 50 kΩ, 500 kΩ, 5 MΩ, 30 MΩ
    Accuracy±(0.6% + 5 counts) 50 Ω ±(2% + 20 counts)
    Full scale reading50 Ω to 5 MΩ – 5000 counts, 30 MΩ – 3000 counts
    Measurement current0.5 mA to 50 nA, decreases with increasing ranges
    Open circuit voltage<4 V
    Continuity (Cont)
    Beep<(30 Ω ±5 Ω) in 50 Ω range
    Measurement current0.5 mA
    Detection of shorts of≥1 ms
    Diode
    Measurement voltage@0.5 mA>2.8 V
    @open circuit<4 V
    Measurement current0.5 mA
    Polarity+ on input A, – on COM
    Capacitance (CAP)
    Ranges50 nF, 500 nF, 5 μF, 50 μF, 500 μF
    Full scale reading5000 counts
    Measurement current500 nA to 0.5 mA, increases with increasing ranges

     

    Advanced meter functions
    Zero SetSet actual value to reference
    AutoHold (on A)Captures and freezes a stable measurement result. Beeps when stable. AutoHold works on the main meter reading, with thresholds of 1 Vpp for AC signals and 100 mV for DC signals.
    Fixed decimal pointActivated by using attenuation keys

     

    Cursor Readout (124B and 125B)
    SourcesA, B
    Single vertical lineAverage, min and max readout
    Average, min, max and time from start of readout (in ROLL mode; instrument in HOLD)
    Min, max and time from start of readout (in RECORDER mode; instrument in HOLD)
    Harmonics values in POWER QUALITY mode.
    Dual vertical linesPeak-peak, time distance and reciprocal time distance readout
    Average, min, max and time distance readout (in ROLL mode; instrument in HOLD)
    Dual horizontal linesHigh, low and peak-peak readout
    Rise or fall timeTransition time, 0%-level and 100%-level readout (manual or auto leveling; auto leveling only
    possible in single channel mode)
    AccuracyAs oscilloscope accuracy

     

    Recorder
    The recorder captures meter readings in Meter Recorder mode or continuously captures waveform samples in Scope Recorder mode. The information is stored on internal memory or on optional SD card (with the 125B or 124B).
    The results are displayed as Chart recorder display that plots a graph of min and max values of Meter measurements over time or as a waveform recorder display that plots all the captured samples.
    Meter readings
    Measurement SpeedMaximum 2 measurement/s
    Record Size (min, max, average)2 M readings for 1 channel
    Recorded Time Span2 weeks
    Maximum number of events1024
    Waveform record
    Maximum sample rate400 K sample/s
    Size Internal memory400 M samples Recorded Time
    Span internal memory15 minutes at 500 μs/div
    11 hours at 20 ms/div
    Record Size SD card1.5 G samples
    Recorded Time Span SD card11 hours at 500 μs/div
    14 days at 20 ms/div
    Maximum number of events64

     

    BusHealth tester (Fluke 125B only)
    TypeSubtypeProtocol
    AS-iNEN-EN50295
    CANISO-11898
    Interbus SRS-422EIA-422
    ModbusRS-232RS-232/EIA-232
    RS-485RS-485/EIA-485
    Foundation FieldbusH161158 type 1, 31.25 kBit
    ProfibusDPEIA-485
    PA61158 type 1

     

    Miscellaneous
    DisplayType5.7-inch color active matrix TFT
    Resolution640 x 480 pixels
    Waveform DisplayVertical10 div of 40 pixels
    Horizontal12 div of 40 pixels
    PowerExternalVia Power Adapter BC430
    Input voltage10 V DC to 21 V DC
    Power consumption5 W typical
    Input connector5 mm jack
    InternalVia Battery Pack BP290
    Battery powerRechargeable Li-Ion 10.8 V
    Operating time7 hours with 50% backlight brightness
    Charging time4 hours with test tool off,  7 hours with test tool on
    Allowable ambient temp0 to 40 °C (32 to 104 °F) during charging
    MemoryInternal memory can store 20 data sets  (screen waveform and setup)Micro SD card slot with optional SD card  (max size of 32 GB)
    MechanicalSize259 x 132 x 55 mm
    (10.2 x 5.2 x 2.15 in)
    Weight1.4 kg (3.2 lb) including battery pack
    InterfaceOptically isolatedTransfer screen copies (bitmaps), settings and data
    USB to PC/laptopOC4USB optically isolated USB adapter/cable, (optional), using FlukeView® software for Windows®.
    Optional WiFi adapterFast transfer of screen copies (bitmaps), settings and data to PC/laptop, tablet, smartphone, etc. A USB port is provided for attaching the WiFi dongle. Do not use the USB port with a cable for safety reasons.

     

    Environmental
    EnvironmentalMIL-PRF-28800F, Class 2
    TemperatureBattery Operation0 to 40 °C (32 to 104 °F)
    Power Adapter Operation0 to 50 °C (32 to 122 °F)
    Storage-20 to 60 °C (-4 to 140 °F)
    Humidity (Operating)@ 0 to 10 °C (32 to 50 °F)Non-condensing
    @ 10 to 30 °C (50 to 86 °F)95%
    @ 30 to 40 °C (86 to 104 °F)75%
    @ 40 to 50 °C (104 to 122 °F)45%
    Storage@ -20 to 60 °C (-4 to 140 °F)Non-condensing
    AltitudeOperating at 3 km (10,000 feet)CAT III 600 V
    Operating at 2 km (6,600 feet)CAT IV 600 V
    Storage12 km (40,000 feet)
    EMC electromagnetic compatibilityInternationalIEC 61326-1: Industrial, CISPR 11:  Group 1, Class A
    Korea (KCC)Class A Equipment (Industrial Broadcasting & Communication Equipment)
    USA (FCC)47 CFR 15 subpart B. This product is considered an exempt device per clause 15.103.
    Wireless radio with adapterFrequency range2412 MHz to 2462 MHz
    Output power<100 mW
    Enclosure protectionIP51, ref: EN/IEC60529
    SafetyGeneralIEC 61010-1: Pollution Degree 2
    MeasurementIEC 61010-2-033: CAT IV 600 V/CAT III 750 V
    Max. input voltage input A and BDirect on input or with leads600 Vrms CAT IV for derating
    With Banana-to-BNC Adapter BB120600 Vrms for derating
    Max. floating voltage from any terminal to ground600 Vrms Cat IV, 750 Vrms up to 400 Hz
    • Fluke 123B Hand-Held Oscilloscope
    • Shielded Test Leads with Black Ground Leads
    • Test Lead Black (for Grounding)
    • Hook Clips (red, blue)
    • Banana-to-BNC Adapters (black, x1)
    • USB Angled Adapter
    • WiFi USB Adapter*
    • Switch Mode Power Supply, Adapter/Battery Charger
    • Rechargeable Li-ion Battery Pack

    Provide us your contact detailsone of our product experts will contact you to discuss your needs or schedule a demonstration at a time that suits

    Product selected: Model #







      *Demonstrations can only be scheduled within the UAE

      Sign up to stay in the know-how of our latest products, updates, special offers, and more.

      • Subscription Form