• Store Locator
  • Schedule a
    Demo
  • Add products to your Toolbox to save it for requesting a quote while you keep browsing for other products to complete your list.

    My
    Toolbox
  • expression
    Create a Requisition

    FLUKE 1550C-Kit 5kV Insulation Resistance Tester Kit; 250V – 5000V

    # 1550C-Kit

    • Test voltages up to 5kV provides solutions for all applications
    • Voltage breakdown detection alerts
    • Selectable test voltages in 50 V steps from 250 to 1000 V; and 100 V steps above 1000 V
    FLUKE
    • FLUKE
    • 1550C-Kit
    • Type

    Quantity:

    - +
      ADD TO MY TOOLBOX
    Where to buy this product?
    • Test voltages to up 5 kV and save time by trending on the spot only with Fluke Connectª
    • CAT III 1000 V; CAT IV 600 V safety rating
    • Warning function alerts the user that line voltage is present and gives the voltage reading up to 600 V AC or DC for increased user safety
    • Selectable test voltages in 50 V steps from 250 V to 1000 V; and 100 V steps above 1000 V
    • Measurements can be stored in up to 99 memory locations; with each location assigned a unique; user defined; label for easy recall
    • Automatic calculation of Dielectric Absorption (DAR) and Polarization Index (PI) with no additional setup
    • Guard system eliminates the effect of surface leakage current on high-resistance measurements
    • Large digital/analog LCD for easy viewing
    • Capacitance and leakage current measurement
    • Ramp function for breakdown testing
    • Resistance measurements up to 2 TO
    • Timer settings up to 99 minutes for timed tests
    Insulation Resistance Measurement
    Test voltage (DC)
    250 V Range < 250 kΩ,
    250 kΩ to 5 GΩ
    5 GΩ to 50 GΩ
    > 50 GΩ
    Accuracy (± reading) Unspecified
    5%
    20%
    Unspecified
    500 V Range < 500 kΩ
    500 kΩ to 10 GΩ
    10 GΩ to 100 GΩ
    > 100 GΩ
    Accuracy (± reading) Unspecified
    5%
    20%
    Unspecified
    1000 V Range < 1 MΩ
    1 MΩ to 20 GΩ
    20 GΩ to 200 GΩ
    > 200 GΩ
    Accuracy (± reading) Unspecified
    5%
    20%
    Unspecified
    2500 V Range < 2.5 MΩ
    2.5 MΩ to 50 GΩ
    50 GΩ to 500 GΩ
    > 500 GΩ
    Accuracy (± reading) Unspecified
    5%
    20%
    Unspecified
    5000 V Range < 5 MΩ
    5 MΩ to 100 GΩ
    100 GΩ to 1 TΩ
    > 1 TΩ
    Accuracy (± reading) Unspecified
    5%
    20%
    Unspecified
    Bar graph range 0 to 1 TΩ (1550C) – 0 to 2 TΩ (1555)
    Insulation test voltage accuracy -0%, +10% at 1 mA load current
    Induced AC mains current rejection 2 mA maximum
    Charging rate for capacitive load 5 seconds per μF
    Discharge rate for capacitive load 1.5 s/μF
    Leakage current measurement Range 1 nA to 2 mA
    Accuracy ± (5% + 2 nA)
    Capacitance measurement Range 0.01 μF to 15.00 μF
    Accuracy ± (15% rdg + 0.03 μF)
    Timer Range 0 to 99 minutes
    Resolution setting 1 minute
    Resolution indication 1 second
    Live circuit warning Warning range 30 V to 660 V AC/DC, 50/60 Hz
    Voltage accuracy ± (15% + 2 V)
    Software specifications FlukeView Forms™ basic software requires a PC running Windows XP, Windows Vista , Windows 7 or Windows 8.
    General Specifications
    Display 75 x 105 mm
    Power 12 V lead-acid rechargeable battery, Yuasa NP2.8-12
    Charger Input (AC) 85 V to 250 V AC 50/60 Hz 20 VA
    This Class II (double insulated) instrument is supplied with a Class 1 (grounded) power cord. The protective earth terminal (ground pin) is not connected internally. The extra pin is for added plug retention only.
    Dimensions 269 x 277 x 160 mm (10.6 x 10.9 x 6.3 in)
    Weight 3.7 kg (8.2 lb)
    Temperature (operating) -20°C to 50°C (-4°F to 122°F)
    Temperature (storage) -20°C to 65°C (-4°F to 149°F)
    Humidity 80% to 31°C decreasing linearly to 50% at 50°C
    Altitude 2000 m
    Enclosure sealing IP40
    Input overload protection 1000 V AC
    Electromagnetic compatibility EN 61326
    Safety compliance IEC 61010-1: Overvoltage category II, Pollution Degree 2.
    IEC 61010-2-030: Measurement 600V CAT IV / 1000V CAT III
    IEC 61557-1, IEC 61557-2
    • Fluke 1550C/KIT Insulation Resistance Tester Kit
    • Test cables with alligator clips (red, black, green)
    • Infrared adapter with interface cable
    • FlukeView¨ Forms Basic CD-ROM
    • AC power cord
    • Soft carrying case
    • English manual
    • User’s manual on CD-ROM
    • Quick reference card
    • Software license agreement
    • Registration card
    • FlukeView¨ Forms installation guide
    • USB-IR cable installation guide
    • Heavy duty alligator clip leads

    Provide us your contact detailsone of our product experts will contact you to discuss your needs or schedule a demonstration at a time that suits

    Product selected: Model #







    *Demonstrations can only be scheduled within the UAE