• Store Locator
  • Schedule a
    Demo
  • Add products to your Toolbox to save it for requesting a quote while you keep browsing for other products to complete your list.

    My
    Toolbox
  • MEGGER PAT410 Full Database Driven Portable Appliance Testers – 200 mA bond Test

    # PAT410

    • Vast on-board memory to keep you the job longer
    • Continuous operation, no need to stop and wait for the tester to cool down
    • Instant re-start as you move from room to room testing
    MEGGER
    • MEGGER
    • PAT410

    Quantity:

    - +
      ADD TO MY TOOLBOX
    Where to buy this product?

    PAT410 perfect for those content to bond test solely at 200 mA, The smallest, lightest of the PAT400 series weighs only 2.7 kg.

    • Vast on-board memory to keep you the job longer
    • Continuous operation, no need to stop and wait for the tester to cool down
    • Instant re-start as you move from room to room testing
    • Soft keys to speed you through the testing process
    • Full PAT testing including RCD testing
    • Most productive tester in its class
    Electrical Supply Range
    PAT410, PAT420, PAT450 230 V ±10 @ 50/60 Hz.
    PAT420, PAT450 110 V ± 10% + 110 V ±10% @50Hz.
    Bond Test (10A and 25A) Not PAT410
    Open Circuit Voltage 9 V AC ±10% ± 0.1 V (supply: 230 V 50 Hz).
    Earth Bond Resistance Accuracy ±5% ± 3 digits (0 to 0.49 Ω)
    ±5% ±5 (0.5 to 0.99 Ω).
    Display Range 0 to 1.99 Ω.
    Continuity Test (200mA)
    Continuity Test Voltage 9 V AC ± 10% ± 0.1 V (supply: 230 V 50 Hz).
    Continuity Resistance Accuracy ±5% ± 3 digits (0 to 0.49 Ω)
    ±5% ± 5 digits (0.5 to 0.99 Ω).
    Continuity Resistance Resolution 10 mΩ (1 to 19.99 Ω).
    Display Range 0 to 19.99 Ω.
    Insulation Test (250V and 500V)
    Insulation Resistance Accuracy (230 V) ±2% ± 5 digits (0 to 19.9 MΩ)
    ±5% ± 10 digits (20 to 99.99 MΩ).
    Insulation Resistance Resolution 0.01 MΩ.
    Display Range 0 to 99.99 MΩ.
    Substitute Leakage Test
    Test Voltage and Frequency 40 V AC ±10% nominal mains frequency.
    Leakage Current Accuracy ±5% ± 5 digits.
    Leakage Current Resolution 0.01 mA.
    Display Range 0 to 19.99 mA.
    Differential Leakage Current
    Test Voltage Nominal mains 110/230 V AC.
    Test Frequency Nominal mains 50/60 Hz.
    Differential Leakage Current Accuracy ±5% ± 0.05 mA (1.0 mA to 9.99 mA)
    ±5% ± 0.1 mA (0.1 mA to 0.99 mA).
    Resolution 0.01 mA.
    Display/Measurement Range 0.10 mA to 19.99 mA.
    Touch Current Test
    Test Voltage and Frequency Nominal mains supply.
    Touch Current Accuracy ±5% ± 5 digits.
    Touch Current Resolution 0.01 mA.
    Display 0 to 10 mA.
    Operational Test
    Test Voltage and Frequency Nominal mains supply.
    VA Rating 230 V 3700 VA
    110 V 1800 VA.
    VA Accuracy ±5% ± 10 digits (0 to 99 VA)
    ±5% ± 50 digits (100 VA to 999 VA)
    ±5% ± 100 digits (1000 VA to 3700 VA).
    Resolution 1 VA (0 to 3700 VA).
    Display Range 0 to 3990 VA.
    Extension Lead Test
    Tests Performed Bond, insulation and polarity.
    Polarity Test Voltage 12 V.
    Polarity checks Lead ok
    Live neutral S/C
    Live neutral reversed
    Live/neutral O/C.
    Flash Test (PAT450 only)
    Flash Test Voltage 1500 V AC nominal for class 1
    3000 V AC nominal for class 2.
    Flash Test Current <3.5 mA short circuit @ 253 V primary supply voltage.
    Flash Test Breakdown Current Accuracy ±5% ±5 digits.
    Flash Test Breakdown Current Resolution 0.01 mA.
    Display Range 0 to 3.0 mA.
    Portable RCD Test
    Test Voltage and Frequency Nominal mains supply.
    Test Current Accuracy -8% to -2% (1/2 x I)
    +2 to +8% (1 x I, 5 x I).
    Trip Time Accuracy ±1% ± 5 digits.
    Trip Time Resolution 0.1 ms.
    Display Range 0 to 1999 ms (1/2 x I)
    0 to 300 ms (1 x I)
    0 to 40 ms (5 x I).
    Fuse Test
    Test Voltage 3.3 V.
    Warning Audible beep if fuse is OK.
    Environmental
    Operating Temperature -10 to 50°C.
    Storage Temperature -20 to 60°C.
    Humidity 90% RH @ -10 to 30°C
    75% RH @ +30 to 50°C.
    Maximum Altitude 2000m.
    Ingress Protection IP40.
    General
    Weight 4.4 kg.
    Dimensions 180 (H) x 255 (W) x 320 mm (L).
    Safety IEC 61010-1: CAT II 300 V.
    EMC IEC 61326-1: 2006
    IEC 61326-2-2: 2005.
    Megger PAT410 warranty One-year.