• Store Locator
  • Schedule a
    Demo
  • Add products to your Toolbox to save it for requesting a quote while you keep browsing for other products to complete your list.

    My
    Toolbox
  • MEGGER PAT410 Full Database Driven Portable Appliance Testers – 200 mA bond Test

    # PAT410

    • Vast on-board memory to keep you the job longer
    • Continuous operation, no need to stop and wait for the tester to cool down
    • Instant re-start as you move from room to room testing

    PAT410 perfect for those content to bond test solely at 200 mA, The smallest, lightest of the PAT400 series weighs only 2.7 kg.

    • Vast on-board memory to keep you the job longer
    • Continuous operation, no need to stop and wait for the tester to cool down
    • Instant re-start as you move from room to room testing
    • Soft keys to speed you through the testing process
    • Full PAT testing including RCD testing
    • Most productive tester in its class
    Electrical Supply Range
    PAT410, PAT420, PAT450230 V ±10 @ 50/60 Hz.
    PAT420, PAT450110 V ± 10% + 110 V ±10% @50Hz.
    Bond Test (10A and 25A) Not PAT410
    Open Circuit Voltage9 V AC ±10% ± 0.1 V (supply: 230 V 50 Hz).
    Earth Bond Resistance Accuracy±5% ± 3 digits (0 to 0.49 Ω)
    ±5% ±5 (0.5 to 0.99 Ω).
    Display Range0 to 1.99 Ω.
    Continuity Test (200mA)
    Continuity Test Voltage9 V AC ± 10% ± 0.1 V (supply: 230 V 50 Hz).
    Continuity Resistance Accuracy±5% ± 3 digits (0 to 0.49 Ω)
    ±5% ± 5 digits (0.5 to 0.99 Ω).
    Continuity Resistance Resolution10 mΩ (1 to 19.99 Ω).
    Display Range0 to 19.99 Ω.
    Insulation Test (250V and 500V)
    Insulation Resistance Accuracy (230 V)±2% ± 5 digits (0 to 19.9 MΩ)
    ±5% ± 10 digits (20 to 99.99 MΩ).
    Insulation Resistance Resolution0.01 MΩ.
    Display Range0 to 99.99 MΩ.
    Substitute Leakage Test
    Test Voltage and Frequency40 V AC ±10% nominal mains frequency.
    Leakage Current Accuracy±5% ± 5 digits.
    Leakage Current Resolution0.01 mA.
    Display Range0 to 19.99 mA.
    Differential Leakage Current
    Test VoltageNominal mains 110/230 V AC.
    Test FrequencyNominal mains 50/60 Hz.
    Differential Leakage Current Accuracy±5% ± 0.05 mA (1.0 mA to 9.99 mA)
    ±5% ± 0.1 mA (0.1 mA to 0.99 mA).
    Resolution0.01 mA.
    Display/Measurement Range0.10 mA to 19.99 mA.
    Touch Current Test
    Test Voltage and FrequencyNominal mains supply.
    Touch Current Accuracy±5% ± 5 digits.
    Touch Current Resolution0.01 mA.
    Display0 to 10 mA.
    Operational Test
    Test Voltage and FrequencyNominal mains supply.
    VA Rating230 V 3700 VA
    110 V 1800 VA.
    VA Accuracy±5% ± 10 digits (0 to 99 VA)
    ±5% ± 50 digits (100 VA to 999 VA)
    ±5% ± 100 digits (1000 VA to 3700 VA).
    Resolution1 VA (0 to 3700 VA).
    Display Range0 to 3990 VA.
    Extension Lead Test
    Tests PerformedBond, insulation and polarity.
    Polarity Test Voltage12 V.
    Polarity checksLead ok
    Live neutral S/C
    Live neutral reversed
    Live/neutral O/C.
    Flash Test (PAT450 only)
    Flash Test Voltage1500 V AC nominal for class 1
    3000 V AC nominal for class 2.
    Flash Test Current<3.5 mA short circuit @ 253 V primary supply voltage.
    Flash Test Breakdown Current Accuracy±5% ±5 digits.
    Flash Test Breakdown Current Resolution0.01 mA.
    Display Range0 to 3.0 mA.
    Portable RCD Test
    Test Voltage and FrequencyNominal mains supply.
    Test Current Accuracy-8% to -2% (1/2 x I)
    +2 to +8% (1 x I, 5 x I).
    Trip Time Accuracy±1% ± 5 digits.
    Trip Time Resolution0.1 ms.
    Display Range0 to 1999 ms (1/2 x I)
    0 to 300 ms (1 x I)
    0 to 40 ms (5 x I).
    Fuse Test
    Test Voltage3.3 V.
    WarningAudible beep if fuse is OK.
    Environmental
    Operating Temperature-10 to 50°C.
    Storage Temperature-20 to 60°C.
    Humidity90% RH @ -10 to 30°C
    75% RH @ +30 to 50°C.
    Maximum Altitude2000m.
    Ingress ProtectionIP40.
    General
    Weight4.4 kg.
    Dimensions180 (H) x 255 (W) x 320 mm (L).
    SafetyIEC 61010-1: CAT II 300 V.
    EMCIEC 61326-1: 2006
    IEC 61326-2-2: 2005.
    Megger PAT410 warrantyOne-year.

    Provide us your contact detailsone of our product experts will contact you to discuss your needs or schedule a demonstration at a time that suits

    Product selected: Model #







      *Demonstrations can only be scheduled within the UAE

      Sign up to stay in the know-how of our latest products, updates, special offers, and more.

      • Subscription Form