Add products to your Toolbox to save it for requesting a quote while you keep browsing for other products to complete your list.
# PAT150R
PAT150R is a rechargeable version of the PAT150.
Specifications | Megger PAT120 | Megger PAT150 |
---|---|---|
Environmental Conditions | ||
Operating Ambient | 20°C | 20°C |
Humidity | Nominal humidity | Nominal humidity |
Continuity Testing | ||
Test Voltage | Compliance voltage: +4V DC-0 / +10% (open circuit) | Compliance voltage: +4V DC-0 / +10% (open circuit) |
Test Current | Bi-directional +200mA-0% + 50mA (into 2Ω load) | Bi-directional +200mA-0% + 50mA (into 2Ω load) |
Continuity Accuracy | Resistance: ±5% ± 3 digits (0 to 19.99Ω) | Resistance: ±5% ± 3 digits (0 to 19.99Ω) |
Resistance Resolution | 10mΩ | 10mΩ |
Display Range | 0.01 to 19.99Ω | 0.01 to 19.99Ω |
Continuity Test Nulling | Up to 9.99Ω | Up to 9.99Ω |
Test Duration | Selected during test automatically | User-selectable from 2 seconds to 20 seconds or selected during test to 180 seconds |
Insulation Test | ||
Insulation Procedure | 250V DC: -0% / +25% open circuit | 250V DC: -0% / +25% open circuit500V DC: -0% / +25% open circuit ≥ 500V 0% DC across 0.5MΩ load |
Short Circuit/Charge Current | <2mA DC | <2mA DC |
Insulation Accuracy | ±3% ± 10 digits (0 to 99.9MΩ) | ±3% ± 10 digits (0 to 99.9MΩ) |
Resolution | 0.01MΩ | 0.01MΩ |
Display Range | 0.10M to 99.99MΩ | 0.10M to 99.99MΩ |
Test Duration | Selected during test automatically | User selectable from 2 seconds to 20 seconds or selected during test to 180 seconds |
Substitute Leakage Test | ||
Leakage Current | Accuracy ±5% ± 3 digits | Accuracy ±5% ± 3 digits |
Test Frequency | Nominal mains frequency 50Hz | Nominal mains frequency 50Hz |
Test Voltage | <50V AC | <50V AC |
Resolution | 0.01mA | 0.01mA |
Display Range | 0.10 to 19.99mA | 0.10 to 19.99mA |
Test Duration | User-selectable from 2 secs to 5 seconds | User-selectable from 2 secs to 5 seconds |
Differential Leakage Test (PAT150 Only) | ||
Test Voltage | – | Nominal supply voltage 230V AC |
Test Frequency | – | Nominal mains frequency 50Hz |
Test Accuracy | – | ±5% ±3d ± 3μA/A |
Resolution | – | 0.01mA |
Display Range | – | 0.10 to 19.99mA |
Test Duration | – | User-selectable from 2 seconds to 5 seconds |
Touch Current Test (PAT150 Only) | ||
Test Voltage | – | Nominal mains 230V AC |
Test Frequency | – | Nominal mains 50Hz |
Test Accuracy | – | ±5% ± 3 digits |
Resolution | – | 0.01mA |
Display Range | – | 0.10 to 3.99mA |
Test Duration | – | User-selectable from 2 seconds to 5 seconds |
SELV Device Test (PAT150 Only) | ||
Test Voltage | – | 0 to 300V AC |
Measurement Accuracy | – | ±3% ± 3 digits |
Resolution | – | 0.1V AC |
Display Range | – | 0.1 to 300V AC |
Extension Lead Test | ||
Test Voltage | 5V | 5V |
Polarity | Lead OKLive/neutral shorted Live/neutral reversed Live/neutral open circuit | Lead OKLive/neutral shorted Live/neutral reversed Live/neutral open circuit |
Portable RCD Test (PAT150 Only) | ||
Test Voltage | – | Nominal mains 230V |
Test Frequency | – | 50Hz |
Test Current Accuracy | – | +2% to +8% (1 x I, 5 x I) |
Trip Time Accuracy | – | ±1% ± 1ms |
Trip Time Resolution | – | 0.01ms |
Display Range | – | 0 to 200ms (1 x I)0 to 40ms (5 x I) |
Mains Supply Test (PAT150 Only) | ||
Frequency Measurement Range | – | 50Hz |
Test Voltage | – | 40 to 300V AC |
Accuracy | – | ±3% ± 3 digits |
Resolution | – | 0.1V AC |
Display Range | – | 40 to 300V AC |
Circuit Test | ||
Test Voltage | 5V | 5V |
Test Frequency | Nominal mains 50Hz | Nominal mains 50Hz |
Test Current | <100mA short circuit | <100mA short circuit |
Safety | Instrument designed to IEC 61010-1: 2012Test leads designed to IEC 61010-031:2005 300 volts to Earth Category II Mains fuse protection to 250V RMS AC | Instrument designed to IEC 61010-1: 2012Test leads designed to IEC 61010-031:2005 300 volts to Earth Category II Mains fuse protection to 250V RMS AC |
EMC | Designed to meet IEC 61326-1: 2006 and IEC 61326-2-2: 2005 | Designed to meet IEC 61326-1: 2006 and IEC 61326-2-2: 2005 |
Environmental | ||
Operating Temperature | 0 to 40°C | 0 to 40°C |
Storage Temperature | -20 to 60°C | -20 to 60°C |
Humidity | 90% RH @ 10 to 30°C75% RH @ 30 to 40°C | 90% RH @ 10 to 30°C75% RH @ 30 to 40°C |
Max Altitude | 2000m to full safety spec | 2000m to full safety spec |
IP Rating | IP40 (with front cover closed) | IP40 (with front cover closed) |
Mechanical (Batteries) | ||
Battery Life | 3 days based on 120 tests/day using 2000mAh alkaline batteries | 3 days based on 120 tests/day using 2000mAh alkaline batteries |
Battery Type | Supply voltage12V DC (alkaline AA LR6) 9.6V DC (NiMH AA LR6) | Supply voltage12V DC (alkaline AA LR6) 9.6V DC (NiMH AA LR6) |
Weight | 1150g | 1300g |
Dimensions | 203mm (L) x 148mm (W) x 78mm (H) | 203mm (L) x 148mm (W) x 78mm (H) |
Product selected: Model #
*Demonstrations can only be scheduled within the UAE