• Store Locator
  • Schedule a
    Demo
  • Add products to your Toolbox to save it for requesting a quote while you keep browsing for other products to complete your list.

    My
    Toolbox
  • MEGGER PAT120 Handheld Portable Appliance Testers

    # PAT120

    • Simple tick or cross, pass or fail indication plus measurement
    • Tough, rubber armoured with built-in front cover, hardened, scratch-proof display window
    • Includes 250 V insulation and leakage testing for safe IT testing and surge protected devices
    MEGGER
    • MEGGER
    • PAT120

    Quantity:

    - +
      ADD TO MY TOOLBOX
    Where to buy this product?

    PAT120 simple PAT tester offer Class I, Class II and power and extension lead testing with fixed pass limits; because it has two insulation test voltages it can be used to test IT and surge protected equipment.

    • Simple tick or cross, pass or fail indication plus measurement
    • Tough, rubber armoured with built-in front cover, hardened, scratch-proof display window
    • Includes 250 V insulation and leakage testing for safe IT testing and surge protected devices
    • Testing portable and fixed electrical equipment
    • 10 mA and 30 mA portable RCD lead testing (PAT150)
    • Adjustable PASS test limits (PAT150)
    • Substitute and mains powered leakage testing (PAT150)
    • Battery powered with rechargeable options
    Specifications Megger PAT120 Megger PAT150
    Environmental Conditions
    Operating Ambient 20°C 20°C
    Humidity Nominal humidity Nominal humidity
    Continuity Testing
    Test Voltage Compliance voltage: +4V DC

    -0 / +10% (open circuit)

    Compliance voltage: +4V DC

    -0 / +10% (open circuit)

    Test Current Bi-directional +200mA

    -0% + 50mA (into 2Ω load)

    Bi-directional +200mA

    -0% + 50mA (into 2Ω load)

    Continuity Accuracy Resistance: ±5% ± 3 digits (0 to 19.99Ω) Resistance: ±5% ± 3 digits (0 to 19.99Ω)
    Resistance Resolution 10mΩ 10mΩ
    Display Range 0.01 to 19.99Ω 0.01 to 19.99Ω
    Continuity Test Nulling Up to 9.99Ω Up to 9.99Ω
    Test Duration Selected during test automatically User-selectable from 2 seconds to 20 seconds or selected during test to 180 seconds
    Insulation Test
    Insulation Procedure 250V DC: -0% / +25% open circuit 250V DC: -0% / +25% open circuit

    500V DC: -0% / +25% open circuit

    ≥ 500V 0% DC across 0.5MΩ load

    Short Circuit/Charge Current <2mA DC <2mA DC
    Insulation Accuracy ±3% ± 10 digits (0 to 99.9MΩ) ±3% ± 10 digits (0 to 99.9MΩ)
    Resolution 0.01MΩ 0.01MΩ
    Display Range 0.10M to 99.99MΩ 0.10M to 99.99MΩ
    Test Duration Selected during test automatically User selectable from 2 seconds to 20 seconds or selected during test to 180 seconds
    Substitute Leakage Test
    Leakage Current Accuracy ±5% ± 3 digits Accuracy ±5% ± 3 digits
    Test Frequency Nominal mains frequency 50Hz Nominal mains frequency 50Hz
    Test Voltage <50V AC <50V AC
    Resolution 0.01mA 0.01mA
    Display Range 0.10 to 19.99mA 0.10 to 19.99mA
    Test Duration User-selectable from 2 secs to 5 seconds User-selectable from 2 secs to 5 seconds
    Differential Leakage Test (PAT150 Only)
    Test Voltage Nominal supply voltage 230V AC
    Test Frequency Nominal mains frequency 50Hz
    Test Accuracy ±5% ±3d ± 3μA/A
    Resolution 0.01mA
    Display Range 0.10 to 19.99mA
    Test Duration User-selectable from 2 seconds to 5 seconds
    Touch Current Test (PAT150 Only)
    Test Voltage Nominal mains 230V AC
    Test Frequency Nominal mains 50Hz
    Test Accuracy ±5% ± 3 digits
    Resolution 0.01mA
    Display Range 0.10 to 3.99mA
    Test Duration User-selectable from 2 seconds to 5 seconds
    SELV Device Test (PAT150 Only)
    Test Voltage 0 to 300V AC
    Measurement Accuracy ±3% ± 3 digits
    Resolution 0.1V AC
    Display Range 0.1 to 300V AC
    Extension Lead Test
    Test Voltage 5V 5V
    Polarity Lead OK

    Live/neutral shorted

    Live/neutral reversed

    Live/neutral open circuit

    Lead OK

    Live/neutral shorted

    Live/neutral reversed

    Live/neutral open circuit

    Portable RCD Test (PAT150 Only)
    Test Voltage Nominal mains 230V
    Test Frequency 50Hz
    Test Current Accuracy +2% to +8% (1 x I, 5 x I)
    Trip Time Accuracy ±1% ± 1ms
    Trip Time Resolution 0.01ms
    Display Range 0 to 200ms (1 x I)

    0 to 40ms (5 x I)

    Mains Supply Test (PAT150 Only)
    Frequency Measurement Range 50Hz
    Test Voltage 40 to 300V AC
    Accuracy ±3% ± 3 digits
    Resolution 0.1V AC
    Display Range 40 to 300V AC
    Circuit Test
    Test Voltage 5V 5V
    Test Frequency Nominal mains 50Hz Nominal mains 50Hz
    Test Current <100mA short circuit <100mA short circuit
    Safety Instrument designed to IEC 61010-1: 2012

    Test leads designed to IEC 61010-031:2005

    300 volts to Earth Category II

    Mains fuse protection to 250V RMS AC

    Instrument designed to IEC 61010-1: 2012

    Test leads designed to IEC 61010-031:2005

    300 volts to Earth Category II

    Mains fuse protection to 250V RMS AC

    EMC Designed to meet IEC 61326-1: 2006 and IEC 61326-2-2: 2005 Designed to meet IEC 61326-1: 2006 and IEC 61326-2-2: 2005
    Environmental
    Operating Temperature 0 to 40°C 0 to 40°C
    Storage Temperature -20 to 60°C -20 to 60°C
    Humidity 90% RH @ 10 to 30°C

    75% RH @ 30 to 40°C

    90% RH @ 10 to 30°C

    75% RH @ 30 to 40°C

    Max Altitude 2000m to full safety spec 2000m to full safety spec
    IP Rating IP40 (with front cover closed) IP40 (with front cover closed)
    Mechanical (Batteries)
    Battery Life 3 days based on 120 tests/day using 2000mAh alkaline batteries 3 days based on 120 tests/day using 2000mAh alkaline batteries
    Battery Type Supply voltage

    12V DC (alkaline AA LR6)

    9.6V DC (NiMH AA LR6)

    Supply voltage

    12V DC (alkaline AA LR6)

    9.6V DC (NiMH AA LR6)

    Weight 1150g 1300g
    Dimensions 203mm (L) x 148mm (W) x 78mm (H) 203mm (L) x 148mm (W) x 78mm (H)