    MEGGER MIT2500 2.5 kV and 200 GΩ range in a hand held instrument 50 V to 2500 V

    # MIT2500

    • Ideal tester for high voltage electrical and industrial applications
    • Performs insulation resistance tests up to 2.5 kV with 200 Gigaohms maximum resistance
    • Stabilized insulation test voltage remains within specification
    MEGGER
    • MEGGER
    • MIT2500

    Quantity:

    - +
      ADD TO MY TOOLBOX
    Where to buy this product?
    • Ideal tester for high voltage electrical and industrial applications
    • Performs insulation resistance tests up to 2.5 kV with 200 Gigaohms maximum resistance
    • Stabilized insulation test voltage remains within specification
    • Guard terminal allows for high accuracy at higher voltages
    • Adjustable insulation test voltage from 50 V to 2500 V
    • Single range, faster continuity testing from 0.01 ohm to 1 Megaohm
    • Provides clear readout on digital display with large characters and analog arc
    • Offers PI, DAR, and timed test modes
    • Detects live voltages and inhibits insulation testing above user-selected thresholds
    • Buzzer limit alarms may be set for continuity and insulation tests
    • Test lock function holds insulation test on continuously
    • Rechargeable options for mains and car charging
    • Suitable for use on CAT IV applications and supply voltages to 600 V
    Insulation
    Insulation accuracy
    50 Volts 10 GΩ ± 2% ± 2 digits ± 4.0% per GΩ
    100 Volts 20 GΩ ± 2% ± 2 digits ± 2.0% per GΩ
    250 Volts 50 GΩ ± 2% ± 2 digits ± 0.8% per GΩ
    500 Volts 100 GΩ ± 2% ± 2 digits ± 0.4% per GΩ
    1000 Volts 200 GΩ ± 2% ± 2 digits ± 0.2% per GΩ
    2500 Volts 200 GΩ ± 2% ± 2 digits ± 0.2% per GΩ
    Service Error BS EN 61557-2 (2007).
    50V, ± 2.0% ± 2d, 100kΩ – 900kΩ ± 10.5%
    100V, ± 2.0% ± 2d, 100kΩ – 900kΩ ± 10.3%
    250V, ± 2.0% ± 2d, 100kΩ – 900kΩ ± 10.3%
    500V, ± 2.0% ± 2d, 100kΩ – 900kΩ ± 10.3%
    1000V, ± 2.0% ± 2d, 100kΩ – 900kΩ ± 11.5%
    Guard terminal performance <5% error at 500 kΩ parallel circuit resistance with 100 MΩ load
    Display range Analogue: 1 GΩ full scale
    Resolution 0.1 kΩ
    Short circuit/charge current 2 mA +0% -50% to EN 61557-2 (2007) (except 2500 V)
    Terminal voltage accuracy -0% +2% ± 2V
    Test current 1 mA at min. pass value of insulation to a maximum of 2 mA max
    Operation EN61557 : 0.10 MΩ to 1.0 GΩ
    Leakage current display 10% ±3 digits
    Voltage ±3% ±2 digits ±0.5% of rated voltage
    Timer control Countdown timer 60 second (adjustable to 10 minutes)
    Note Above specifications only apply when high quality silicone leads are being used.
    Continuity
    Continuity measurement 0.01 Ω to 1 MΩ (0 to 1000 kΩ on analogue scale)
    Continuity accuracy ± 3% ± 2 digits (0 to 100 Ω )
    ± 5% ± 2 digits (100 Ω – 500 k Ω)
    Service Error BS EN 61557-4 (2007) –
    ± 2.0%, 0.1Ω – 2Ω ± 6.8%
    Open circuit voltage 5 V ± 1 V
    Test current 200 mA (–0 mA +20 mA) (0.01 Ω to 4 Ω)
    Polarity Single polarity (Default) / Dual polarity (configurable on setup).
    Lead resistance Null up to 10 Ω
    Voltage range DC: 0 to 600 V
    AC: 10 mV to 600 V TRMS sinusoidal (15 Hz to 400 Hz)
    Unspecified: 0 – 10 mV (15 to 400 Hz)
    Volt range accuracy DC: ± 2% ± 2 digits
    AC: ± 2% ± 2 digits
    Waveform Non-sinusoidal:
    ± 3% ± 2 digits >100 mV to 600 V TRMS
    ± 8% ± 2 digits 10 mV to 100 mV TRMS
    Default voltmeter ± 0.5% ± 1digit (100 Hz to 400 Hz) unspecified
    Frequency measurement range 15 Hz – 400 Hz
    Frequency measurement accuracy ± 0.5% ± 1 digits
    Capacitance measurement
    Capacitance range 0.1 nF to 10 µF
    Accuracy ± 5.0% ± 2 digits ( 1 nF-10 µF)
    Results storage
    Storage capacity >1000 test results
    Data download Bluetooth® wireless
    Bluetooth® Class II
    Range up to 10 m
    Power supply 6 x 1.5 V cells type IEC LR6
    (AA, MN1500, HP7, AM3 R6HP) Alkaline6 x 1.2 NiMH rechargeable cells may be used.
    Battery life 3000 insulation tests with duty cycle of 5 sec ON /55 sec OFF @ 1000 V into 1 MΩ
    Charger (Optional): 12-15 V dc (accessory interface)
    Dimensions Instrument 228 mm x 108 mm x 63 mm (9.00 in x 4.25 in x 2.32 in)
    Weight 815 g, (1.8 lb)
    Weight (instrument and case) 1.75 kg (3.86 lb)
    Fuse Use only 2 x 500 mA (FF) 1000 V 32 x 6 mm ceramic fuse of high breaking capacity
    HBC 30 kA minimum. Glass fuses MUST
    NOT be fitted
    Safety protection The instruments meet EN 61010-1 (1995) to 600 V phase to earth, Category IV. Refer to safety warnings supplied
    EMC In accordance with IEC 61326 including amendment No.1
    Temperature coefficient <0,1% per °C up to 1 GΩ
    <0,1% per °C per GΩ above 1 GΩ
    Environmental
    Operating temperature range -10 °C to +55 °C
    Humidity 90% RH at 40 °C max
    Storage temperature range -25°C to +70 °C
    Calibration temperature +20 °C
    Maximum altitude 2000 m
    IP rating IP 54
    • – MIT2500 Insulation and Continuity Tester (1006-764)
    • – Set of 1 kV Silicone Test Leads with Probes and Clips (Red, Black, Blue)
    • – Set of 2.5 kV Silicone Test Leads with Clips (Red, Black, Blue)
    • – Owners Information CD
    • – AA Alkaline Batteries (1002-753)
    • – Hard Carrying Case (2006-649)

    Provide us your contact detailsone of our product experts will contact you to discuss your needs or schedule a demonstration at a time that suits