Add products to your Toolbox to save it for requesting a quote while you keep browsing for other products to complete your list.
# MIT2500
Insulation | ||||
Insulation accuracy | ||||
50 Volts | 10 GΩ | ± 2% ± 2 digits ± 4.0% per GΩ | ||
100 Volts | 20 GΩ | ± 2% ± 2 digits ± 2.0% per GΩ | ||
250 Volts | 50 GΩ | ± 2% ± 2 digits ± 0.8% per GΩ | ||
500 Volts | 100 GΩ | ± 2% ± 2 digits ± 0.4% per GΩ | ||
1000 Volts | 200 GΩ | ± 2% ± 2 digits ± 0.2% per GΩ | ||
2500 Volts | 200 GΩ | ± 2% ± 2 digits ± 0.2% per GΩ | ||
Service Error BS EN 61557-2 (2007). | ||||
50V, ± 2.0% ± 2d, 100kΩ – 900kΩ ± 10.5% | ||||
100V, ± 2.0% ± 2d, 100kΩ – 900kΩ ± 10.3% | ||||
250V, ± 2.0% ± 2d, 100kΩ – 900kΩ ± 10.3% | ||||
500V, ± 2.0% ± 2d, 100kΩ – 900kΩ ± 10.3% | ||||
1000V, ± 2.0% ± 2d, 100kΩ – 900kΩ ± 11.5% | ||||
Guard terminal performance | <5% error at 500 kΩ parallel circuit resistance with 100 MΩ load | |||
Display range | Analogue: 1 GΩ full scale | |||
Resolution | 0.1 kΩ | |||
Short circuit/charge current | 2 mA +0% -50% to EN 61557-2 (2007) (except 2500 V) | |||
Terminal voltage accuracy | -0% +2% ± 2V | |||
Test current | 1 mA at min. pass value of insulation to a maximum of 2 mA max | |||
Operation | EN61557 : 0.10 MΩ to 1.0 GΩ | |||
Leakage current display | 10% ±3 digits | |||
Voltage | ±3% ±2 digits ±0.5% of rated voltage | |||
Timer control | Countdown timer 60 second (adjustable to 10 minutes) | |||
Note | Above specifications only apply when high quality silicone leads are being used. | |||
Continuity | ||||
Continuity measurement | 0.01 Ω to 1 MΩ (0 to 1000 kΩ on analogue scale) | |||
Continuity accuracy | ± 3% ± 2 digits (0 to 100 Ω ) ± 5% ± 2 digits (100 Ω – 500 k Ω) Service Error BS EN 61557-4 (2007) – ± 2.0%, 0.1Ω – 2Ω ± 6.8% | |||
Open circuit voltage | 5 V ± 1 V | |||
Test current | 200 mA (–0 mA +20 mA) (0.01 Ω to 4 Ω) | |||
Polarity | Single polarity (Default) / Dual polarity (configurable on setup). | |||
Lead resistance | Null up to 10 Ω | |||
Voltage range | DC: 0 to 600 V AC: 10 mV to 600 V TRMS sinusoidal (15 Hz to 400 Hz) Unspecified: 0 – 10 mV (15 to 400 Hz) | |||
Volt range accuracy | DC: ± 2% ± 2 digits AC: ± 2% ± 2 digits | |||
Waveform | Non-sinusoidal: ± 3% ± 2 digits >100 mV to 600 V TRMS ± 8% ± 2 digits 10 mV to 100 mV TRMS | |||
Default voltmeter | ± 0.5% ± 1digit (100 Hz to 400 Hz) unspecified | |||
Frequency measurement range | 15 Hz – 400 Hz | |||
Frequency measurement accuracy | ± 0.5% ± 1 digits | |||
Capacitance measurement | ||||
Capacitance range | 0.1 nF to 10 µF | |||
Accuracy | ± 5.0% ± 2 digits ( 1 nF-10 µF) | |||
Results storage | ||||
Storage capacity | >1000 test results | |||
Data download | Bluetooth® wireless Bluetooth® Class II | |||
Range | up to 10 m | |||
Power supply | 6 x 1.5 V cells type IEC LR6 (AA, MN1500, HP7, AM3 R6HP) Alkaline6 x 1.2 NiMH rechargeable cells may be used. | |||
Battery life | 3000 insulation tests with duty cycle of 5 sec ON /55 sec OFF @ 1000 V into 1 MΩ Charger (Optional): 12-15 V dc (accessory interface) | |||
Dimensions Instrument | 228 mm x 108 mm x 63 mm (9.00 in x 4.25 in x 2.32 in) | |||
Weight | 815 g, (1.8 lb) | |||
Weight (instrument and case) | 1.75 kg (3.86 lb) | |||
Fuse | Use only 2 x 500 mA (FF) 1000 V 32 x 6 mm ceramic fuse of high breaking capacity HBC 30 kA minimum. Glass fuses MUST NOT be fitted | |||
Safety protection | The instruments meet EN 61010-1 (1995) to 600 V phase to earth, Category IV. Refer to safety warnings supplied | |||
EMC | In accordance with IEC 61326 including amendment No.1 | |||
Temperature coefficient | <0,1% per °C up to 1 GΩ <0,1% per °C per GΩ above 1 GΩ | |||
Environmental | ||||
Operating temperature range | -10 °C to +55 °C | |||
Humidity | 90% RH at 40 °C max | |||
Storage temperature range | -25°C to +70 °C | |||
Calibration temperature | +20 °C | |||
Maximum altitude | 2000 m | |||
IP rating | IP 54 |