Resistance/Current Ranges The green resistance ranges on the keypad indicate low output power (<0.25 W) outputs. Red ranges indicate higher 2.5 W (1 A) and 25 W (10 A) power outputs. Resolution and Accuracy Test current accuracy ±10%
Voltmeter input impedance >200 kΩ Test Current | Resistance Range | Resolution | Accuracy* | Full Scale Voltage | Max Power Output | 0.1 mA | 0 to 2500.0 Ω | 100 mΩ | ±0.2%
±200 mΩ | 25 mV | 2.5 µW | 0.1 mA | 0 to 250.00 Ω | 10 mΩ | ±0.2%
±20 mΩ | 25 mV | 2.5 µW | 1 mA | 0 to 25.000 Ω | 1 mΩ | ±0.2%
±2 mΩ | 25 mV | 25 µW | 10 mA | 0 to 2500.0 Ω | 100 mΩ | ±0.2%
±200 mΩ | 25 mV | 250 µW | 100 mA | 0 to 250.00 Ω | 10 mΩ | ±0.2%
±20 mΩ | 25 mV | 2.5 µW | 1 A | 0 to 25.000 Ω | 1 mΩ | ±0.2%
±2 mΩ | 25 mV | 25 µW | 10 A | 0 to 2500.0 Ω | 0.1 mΩ | ±0.2%
±0.2 mΩ | 25 mV | 0.25 µW | 1 A | 0 to 2500.0 Ω | 100 mΩ | ±0.2%
±200 mΩ | 2.5 mV | 2.5 µW | 10 A | 0 to 250.00 Ω | 10 mΩ | ±0.2%
±20 mΩ | 2.5 mV | 25 µW |
* The accuracy stated assumes forward and reverse measurements. Inductive mode or undirectional mode will introduce an undefined error if an external EMF is present. |
|
Temperature Coefficient | < 0.01% per ºC, from 5 ºC to 40 ºC |
Maximum Altitude | 2000m (6562 ft) to full safety specifications |
Display size/type | Main 5 digit + 2 x 5 digit secondary displays |
Battery type | 6 V, 7Ah sealed lead acid |
Mains voltage input range | 90 – 264 V, 50-60 Hz |
Charge time | 8 hours |
Backlight | LED backlight |
Battery life | 1000 Auto (3 sec) tests |
Auto power down | 300s |
Mode Selection | Rotary switch |
Range selection | Rotary switch |
Weight | 6.7 kg |
Case dimensions | L315mm x W285mm x H181mm |
Pouch for test leads | Yes (lid mounted) |
Test leads | DH4 lead set included |
IP rating | IP65 case closed, IP54 battery operation |
Safety rating | In accordance with IEC61010-1, CATIII 300 V when used with DH7 leads |
Operating temperature and humidity | +5ºC to +45ºC (41ºF to 113ºF) at full specification, -10°C to +50°C (14°F to 122°F) at reduced accuracy of ±0.5%, <90% RH |
Storage temperature and humidity | -25°C to +60°C, <90%RH |
EMC | In accordance with IEC61326-1 (Heavy industrial) |
Noise rejection | Less than 1% ±20 digits additional error with 100 mV peak 50/60 Hz. on the potential leads. Warning will show if hum or noise exceeds this level. |
Maximum lead resistance | 100 mΩ total for 10 A operation irrespective of battery condition. |