General Specifications |
Head cable length (double insulated) | i3000s Flex | 610 mm (24 in) | i3000s Flex-36 | 915 mm (36 in) |
|
Head cable diameter | |
Head bend radius | |
Cable length (head to electronics) | |
Output connection | | 0.5 m cable terminated with safety BNC connector. Supplied with 4mm safety plug adapter |
|
Operating temperature range | | -20 °C to +90 °C (-4 °F to 190 °F) (head) | | -20 °C to +85 °C (-4 °F to 185 °F) (electronics) |
|
Storage temperature range | | -40 °C to +105 °C (-40 °F to 221 °F) (head) | | -20 °C to +85 °C (-4 °F to 185 °F) (electronics) |
|
Operating humidity | | 15 % to 85 % (non-condensing) |
|
Weight | | 180 g (0.396 lb) (head) | | 190 g (0.419 lb) (electronics) |
|
Safety standards | | BS EN 61010-1: 2001 | | BS EN 61010-2-032: 2002 | | BS EN 61010-031: 2002 | | 600 Vrms, Category III, Pollution Degree 2 | | Use of the probe on uninsulated conductors is limited to 600 V AC rms or dc and frequencies below 1 kHz. |
|
EMC standards | | EN 61326: 1998 +A1, A2, & A3 |
|
Maximum conductor size | | 610 mm or 914 mm, depending on model |
|