• Store Locator
  • Schedule a
    Demo
  • Add products to your Toolbox to save it for requesting a quote while you keep browsing for other products to complete your list.

    My
    Toolbox
  • FLUKE 437-II-INTL 400 Hz Power Quality and Energy Analyzer

    # 437-II-INTL

    • Energy loss calculator: Classic active and reactive power measurements, unbalance and harmonic power, are quantified to pinpoint the fiscal costs of energy losses.
    • Troubleshoot real-time: Analyze the trends using the cursors and zoom tools.
    • Power Inverter Efficiency
    • 400 Hz Measurement: By increasing the power frequency to 400 Hz, transformers and motors can be much smaller and lighter than at 50 or 60 Hz, which is an advantage in aircrafts, submarines, space crafts, and other military equipment and hand-held tools. The 437 II model captures power quality measurements for these types of avionic and military systems.
    • Power Inverter Efficiency: Simultaneously measure AC output power and DC input power for power electronics systems using optional DC clamp.
    • PowerWave Data Capture: Capture fast RMS data, show half-cycle and waveforms to characterize electrical system dynamics (generator start-ups, UPS switching etc.).
    • Energy Loss Calculator: Classic active and reactive power measurements, unbalance and harmonic power, are quantified to pinpoint the fiscal costs of energy losses.
    • Troubleshoot Real-Time: Analyze the trends using the cursors and zoom tools.
    • Highest Safety Rating in the Industry: 600 V CAT IV/1000 V CAT III rated for use at the service entrance.
    • Automatic Trending: Every measurement is always automatically recorded, without any set-up.
    • System-Monitor: Ten power quality parameters on one screen according to EN50160 power quality standard.
    • Logger Function: Configure for any test condition with memory for up to 600 parameters at user defined intervals.
    • View Graphs and Generate Reports: With included analysis software.
    • Battery Life: Seven hours operating time per charge on Li-ion battery pack.
    Product Specifications
    VoltModelMeasurement RangeResolutionAccuracy
    Vrms (AC + DC)1 V to 1000 V phase to neutral0.01 V±0.1% of nominal voltage4
    Vpk1 Vpk to 1400 Vpk1 V5% of nominal voltage
    Voltage Crest Factor (CF)1.0 > 2.80.01±5%
    Vfund0.1 V±0.1% of nominal voltage
    Amps (accuracy excluding clamp accuracy)
    Amps (AC + DC)i430-Flex 1x5 A to 6000 A1 A±0.5% ±5 counts
    i430-Flex 10x0.5 A to 600 A0.1 A±0.5% ±5 counts
    1 mV/A 1x5 A to 2000 A1A±0.5% ±5 counts
    1 mV/A 10x0.5 A A to 200 A (AC only)0.1 A±0.5% ±5 counts
    Apki430-Flex8400 Apk1 Arms±5%
    1 mV/A5500 Apk1 Arms±5%
    A Crest Factor (CF)1 to 100.01±5%
    Amps½i430-Flex 1x5 A to 6000 A1 A±1% ±10 counts
    i430-Flex 10x0.5 A to 600 A0.1 A±1% ±10 counts
    1 mV/A 1x5 A to 2000 A1 A±1% ±10 counts
    1 mV/A 10x0.5 A A to 200 A (AC only)0.1 A±1% ±10 counts
    Afundi430-Flex 1x5 A to 6000 A1 A±0.5% ±5 counts
    i430-Flex 10x0.5 A to 600 A0.1 A±0.5% ±5 counts
    1 mV/A 1x5 A to 2000 A1 A±0.5% ±5 counts
    1 mV/A 10x0.5 A A to 200 A (AC only)0.1 A±0.5% ±5 counts
    Hz
    Fluke 437 @ 50 Hz nominal42.500 Hz to 57.500 Hz0.001 Hz±0.01 Hz
    Fluke 437 @ 60 Hz nominal51.000 Hz to 69.000 Hz0.001 Hz±0.01 Hz
    Fluke 437 @ 400 Hz nominal340.0 Hz to 460.0 Hz0.1 Hz±0.1 Hz
    Power
    Watts (VA, var)i430-Flexmax 6000 MW0.1 W to 1 MW±1% ±10 counts
    1 mV/Amax 2000 MW0.1 W to 1 MW±1% ±10 counts
    Power Factor (Cos j/DPF)0 to 10.001±0.1% @ nominal load conditions
    Energy
    kWh (kVAh, kvarh)i430-Flex 10xDepends on clamp scaling and V nominal±1% ±10 counts
    Energy Lossi430-Flex 10xDepends on clamp scaling and V nominal±1% ±10 counts Excluding line resistance accuracy
    Harmonics
    Harmonic Order (n)DC, 1 to 50 Grouping: Harmonic groups according to IEC 61000-4-7
    Inter-Harmonic Order (n)OFF, 1 to 50 Grouping: Harmonic and Interharmonic subgroups according to IEC 61000-4-7
    Volts %f0.0% to 100%0.1%±0.1% ±n x 0.1%
    r0.0% to 100%0.1%±0.1% ±n x 0.4%
    Absolute0.0 to 1000 V0.1 V±5% 1
    THD0.0% to 100%0.1%±2.5%
    Amps %f0.0% to 100%0.1%±0.1% ±n x 0.1%
    r0.0% to 100%0.1%±0.1% ±n x 0.4%
    Absolute0.0 to 600 A0.1 A±5% ±5 counts
    THD0.0% to 100%0.1%±2.5%
    Watts %f or r0.0% to 100%0.1%±n x 2%
    AbsoluteDepends on clamp scaling and V nominal±5% ±n x 2% ±10 counts
    THD0.0% to 100%0.1%±5%
    Phase Angle-360° to +0°±n x 1°
    Flicker
    Plt, Pst, Pst (1 min) Pinst0.00 to 20.000.01±5%
    Unbalance
    Volts %0.0% to 20.0%0.1%±0.1%
    Amps %0.0% to 20.0%0.1%±1%
    Mains Signaling
    Threshold LevelsThreshold, limits and signaling duration is programable for two signaling frequencies
    Signaling Frequency60 Hz to 3000 Hz0.1 Hz
    Relative V %0% to 100%0.10%±0.4%
    Absolute V 3 s (3 second avg.)0.0 V to 1000 V0.1 V±5% of nominal voltage
    General Specifications
    CaseDesign Rugged, shock proof with integrated protective holster Drip and dust proof IP51 according to IEC60529 when used in tilt stand position Shock and vibration Shock 30 g, vibration: 3 g sinusoid, random 0.03 g 2 /Hz according to MIL-PRF-28800F Class 2
    DisplayBrightness: 200 cd/m 2 typ. using power adapter, 90 cd/m 2 typical using battery power Size: 127 x 88 mm (153 mm/6.0 in diagonal) LCD Resolution: 320 x 240 pixels Contrast and brightness: user-adjustable, temperature compensated
    Memory8 GB SD card (SDHC compliant, FAT32 formatted) standard, upto 32 GB optionally Screen save and multiple data memories for storing data including recordings (dependent on memory size)
    Real-Time ClockTime and date stamp for Trend mode, Transient display, System Monitor and event capture
    Environmental
    Operating Temperature0°C ~ +40°C; +40°C ~ +50°C excl. battery
    Storage Temperature-20°C ~ +60°C
    Humidity+10°C ~ +30°C: 95% RH non-condensing
    +30°C ~ +40°C: 75% RH non-condensing
    +40°C ~ +50°C: 45% RH non-condensing
    Maximum Operating AltitudeUp to 2,000 m (6666 ft) for CAT IV 600 V, CAT III 1000 V
    Up to 3,000 m (10,000 ft) for CAT III 600 V, CAT II 1000 V
    Maximum storage altitude 12 km (40,000 ft)
    Electro-Magnetic-Compatibility (EMC)EN 61326 (2005-12) for emission and immunity
    InterfacesMini-USB-B, Isolated USB port for PC connectivity SD card slot accessible behind instrument battery
    WarrantyThree years (parts and labor) on main instrument, one year on accessories
    View full family specifications »
    1. ±5% if ≥ 1% of nominal voltage ±0.05% of nominal voltage if < 1% of nominal voltage
    2. 50 Hz / 60 Hz nominal frequency according to IEC 61000-4-30
    3. 400 Hz measurements are not supported for Flicker, Mains Signaling and Monitor Mode
    4. For nominal voltage 50 V to 500 V
    • BC430 Power Adapter
    • International Plug Adapter Set
    • BP290 (Single Capacity Li-ion Battery) 28 Wh (7 hours or more)
    • TLS430 Test Lead and Alligator Clip Set
    • WC100 Color Coding Clips and Regional Decals
    • i430flex-TF, 24 inch (61 cm) Length, 4 Clamps
    • 8 GB SD Card
    • PowerLog on CD (includes operator manuals in PDF format)
    • USB Cable A-B Mini

    Provide us your contact detailsone of our product experts will contact you to discuss your needs or schedule a demonstration at a time that suits

    Product selected: Model #







      *Demonstrations can only be scheduled within the UAE

      Sign up to stay in the know-how of our latest products, updates, special offers, and more.

      • Subscription Form