• Store Locator
  • Schedule a
    Demo
  • Add products to your Toolbox to save it for requesting a quote while you keep browsing for other products to complete your list.

    My
    Toolbox
  • Create a Requisition

    FLUKE 1555-Kit 10kV Insulation Resistance Tester Kit; 250V – 10000V

    # 1555-Kit

    • Automatic calculation of Dielectric Absorption (DAR) and Polarization Index (PI) with no additional setup
    • Guard system eliminates the effect of surface leakage current on high-resistance measurements
    • Selectable test voltages in 50 V steps from 250 V to 1000 V, and 100 V steps above 1000 V
    FLUKE
    • FLUKE
    • 1555-Kit
    • 10KV Insulation Tester

    Evaluate the trends, eliminate the doubt

     

    The Fluke 1555 insulation resistance tester kit offers digital insulation testing up to 10 kV in an industrial strength case, with all the heavy duty leads and clips you need. Plus, the Fluke Connect wireless app performs tests and collects data while you stay a safe distance away.

    Remote operation lets you spend as little time as possible in potentially hazardous zones. Real-time trending shows a live graph on your phone, rather than a hard-to-read set of changing values. And you can create reports quickly, simply using drag-and-drop – something you won’t find anywhere else

    • Automatic calculation of Dielectric Absorption (DAR) and Polarization Index (PI) with no additional setup
    • Guard system eliminates the effect of surface leakage current on high-resistance measurements
    • Selectable test voltages in 50 V steps from 250 V to 1000 V, and 100 V steps above 1000 V
    • CAT III 1000 V, CAT IV 600 V safety rating
    • Warning function alerts the user that line voltage is present and gives the voltage reading up to 600 V AC or DC for increased user safety
    • Measurements can be stored in up to 99 memory locations, with each location assigned a unique, user defined, label for easy recall
    • Long battery life gives the user over 750 tests between charges
    • Large digital/analog LCD for easy viewing
    • Capacitance and leakage current measurement
    • Ramp function for breakdown testing
    • Resistance measurements up to 2 TΩ
    • Timer settings up to 99 minutes for timed tests
    • 3-year warranty
    Electrical Specifications
    The tester’s accuracy is specified for one year after calibration at operating temperatures of 0°C to 35°C. For operating temperatures outside the range (-20°C to 0°C and 35°C to 50°C), add ±.25% per °C, except on the 20% bands add ±1% per °C.
    Insulation Resistance Measurement
    Test voltage (DC)
    250 VRange< 250 kΩ,
    250 kΩ to 5 GΩ
    5 GΩ to 50 GΩ
    > 50 GΩ
    Accuracy (± reading)Unspecified
    5%
    20%
    Unspecified
    500 VRange< 500 kΩ
    500 kΩ to 10 GΩ
    10 GΩ to 100 GΩ
    > 100 GΩ
    Accuracy (± reading)Unspecified
    5%
    20%
    Unspecified
    1000 VRange< 1 MΩ
    1 MΩ to 20 GΩ
    20 GΩ to 200 GΩ
    > 200 GΩ
    Accuracy (± reading)Unspecified
    5%
    20%
    Unspecified
    2500 VRange< 2.5 MΩ
    2.5 MΩ to 50 GΩ
    50 GΩ to 500 GΩ
    > 500 GΩ
    Accuracy (± reading)Unspecified
    5%
    20%
    Unspecified
    5000 VRange< 5 MΩ
    5 MΩ to 100 GΩ
    100 GΩ to 1 TΩ
    > 1 TΩ
    Accuracy (± reading)Unspecified
    5%
    20%
    Unspecified
    10000 VRange< 10 MΩ
    10 MΩ to 200 GΩ
    200 GΩ to 2 TΩ
    > 2 TΩ
    Accuracy (± reading)Unspecified
    5%
    20%
    Unspecified
    Bar graph range0 to 1 TΩ (1550C) – 0 to 2 TΩ (1555)
    Insulation test voltage accuracy-0%, +10% at 1 mA load current
    Induced AC mains current rejection2 mA maximum
    Charging rate for capacitive load5 seconds per μF
    Discharge rate for capacitive load1.5 s/μF
    Leakage current measurementRange1 nA to 2 mA
    Accuracy±(5% + 2 nA)
    Capacitance measurementRange0.01 μF to 15.00 μF
    Accuracy±(15% rdg + 0.03 μF)
    TimerRange0 to 99 minutes
    Resolution setting1 minute
    Resolution indication1 second
    Live circuit warningWarning range30 V to 660 V AC/DC, 50/60 Hz
    Voltage accuracy±(15% + 2 V)
    Software specificationsFlukeView Forms™ basic software requires a PC running Windows XP, Windows Vista , Windows 7 or Windows 8.
    General Specifications
    Display75 x 105 mm
    Power12 V lead-acid rechargeable battery, Yuasa NP2.8-12
    Charger Input (AC)85 V to 250 V AC 50/60 Hz 20 VA
    This Class II (double insulated) instrument is supplied with a Class 1 (grounded) power cord. The protective earth terminal (ground pin) is not connected internally. The extra pin is for added plug retention only.
    Dimensions269 x 277 x 160 mm (10.6 x 10.9 x 6.3 in)
    Weight3.7 kg (8.2 lb)
    Temperature (operating)-20°C to 50°C (-4°F to 122°F)
    Temperature (storage)-20°C to 65°C (-4°F to 149°F)
    Humidity80% to 31°C decreasing linearly to 50% at 50°C
    Altitude2000 m
    Enclosure sealingIP40
    Input overload protection1000 V AC
    Electromagnetic compatibilityEN 61326
    Safety complianceIEC 61010-1: Overvoltage category II, Pollution Degree 2.
    IEC 61010-2-030: Measurement 600V CAT IV / 1000V CAT III
    IEC 61557-1, IEC 61557-2
    • Fluke 1555/KIT Insulation Resistance Tester Kit
    • Test cables with alligator clips (red, black, green)
    • Infrared adapter with interface cable
    • FlukeView¨ Forms Basic CD-ROM
    • AC power cord
    • Soft carrying case
    • English manual
    • User’s manual on CD-ROM
    • Quick reference card
    • Software license agreement
    • Registration card
    • FlukeView¨ Forms installation guide
    • USB-IR cable installation guide
    • Heavy duty alligator clip leads

    Provide us your contact detailsone of our product experts will contact you to discuss your needs or schedule a demonstration at a time that suits

    Product selected: Model #







      *Demonstrations can only be scheduled within the UAE

      Sign up to stay in the know-how of our latest products, updates, special offers, and more.

      • Subscription Form