• Store Locator
  • Schedule a
    Demo
  • Add products to your Toolbox to save it for requesting a quote while you keep browsing for other products to complete your list.

    My
    Toolbox
  • FLUKE NETWORKS TS100-PRO-BT-TDR Cable Fault Finder with PowerBT™ Bridge Tap

    # TS100-PRO-BT-TDR

    • Bridge tap detection for xDSL pre-qualification
    • Tests opens and shorts up to 8,000 ft.
    • Patented SmartTone tone generator with five different tones for exact pair identification
    FLUKE NETWORKS
    • FLUKE NETWORKS
    • TS100-PRO-BT-TDR

    Quantity:

    - +
      ADD TO MY TOOLBOX
    Where to buy this product?
    • Bridge tap detection for xDSL pre-qualification
      • Reports distance to multiple bridge taps up to 3,200 ft.
      • Sees past bridge taps to the end of the cable
    • Tests opens and shorts up to 8,000 ft.
    • Patented SmartTone tone generator with five different tones for exact pair identification
    • Built-in TDR (Time Domain Reflector)
    • AC/DC voltage detection
    • One-button testing
    • Built-in toner
    Specifications for the TS100 PRO
    Maximum Length 8,000 feet (2,438 meters) on certain cable types, 4,000 feet (1,220 meters) on most cable types, and 500 feet (152 meters) on cables with high loss. The tester shows -Err if the cable is too long to be correctly measured.
    Representative Maximum Cable Length 8,000 feet (2,438 meters): CAT-3 Twisted Pair

    8,000 feet (2,438 meters): CAT-5 Twisted Pair

    6,000 feet (1,830 meters): 12/2 AC Wire

    3,000 feet (900 meters): RG-6/U TV Coax

    1,500 feet (457 meters): RG-174/U Coax

    Minimum Length No minimum length (can read a bridge tap at 0 feet/meters). Minimum non-zero reading is 2 feet or 1 meter.
    Length Accuracy ±2 feet (±0.6 m) for cables less than 10 feet (3 m)

    ±5 feet (±2 m) for cables longer than 10 feet (3 m) and shorter than 200 feet (60 m)

    +/-3%+/-5 feet (±2 m) for cables longer than 200 feet (60 m)

    Distance to Bridge Tap 0 feet to 3,200 feet (975 meters)
    Minimum Length of Bridge Tap 10% of the distance to the bridge tap. Dependant on the cable characteristics.
    Measurement Rate Maximum of 4 complete measurements per second, decreasing to 2 seconds per measurement based on cable size and uniformity.
    VOP Adjustable from 20 to 99, saved in flash memory.
    Test Technology Time Domain Reflectometry (TDR) with 100 Ω drive impedance, 6v maximum pulse height.
    Cable Type Virtually all two or more conductor cables.
    Power 4 AA alkaline batteries.
    Reverse Battery Protection No damage to the tester will occur if the batteries are installed backwards.
    Battery Life 35 hours (typical)
    Low Battery Indication LED display alternates between LO and bAtt when the battery voltage falls below 4.5v.
    Maximum Output Voltage 4 voltage peak
    Maximum Isolation Voltage 250 volts RMS
    Voltage Measurements Range: 0 volts AC to 115 volts AC; 0 volts DC to ±150 volts DC

    Accuracy: AC: +/-1%+/-2 volts (45 Hz to 65 Hz); DC: +/-1%+/-2 volts DC

    High Voltage Detection AC voltage detected to 115 volts; DC voltage detected to ±150 volts.

    AC voltage ≥90 volts or DC voltage ≥100 volts causes high voltage warnings to show on the display

    SmartTone® (5-tones) Range 7,000 feet (2,134 meters) 
    Toner Range 52,800 feet (16,093 meters)
    Tone Injection Approximately 1 kHz at an amplitude of 80% of battery voltage. Variable frequency and cadence. Tone characteristics change as cable condition changes to “normal-open” from any other condition.
    Impedance Range 35 Ω to 330 Ω with auto-compensation within this range. Cables with impedances outside this range will not be properly tested and may produce erratic or incorrect readings.
    Temperature Range Operating: 32°F to 104°F (0°C to 40°C)

    Storage: 32°F to 131°F (0°C to 55°C)

    Humidity Operating: 20% to 80% relative humidity

    Storage: 0% to 100% relative humidity

    Operating Humidity 80% maximum at 86°F (30°C )

    50% maximum at 104°F (40°C )

    Operating Altitude 9,843 ft max (3,000 m max)
    Weight 1 lb (454 grams)
    Dimensions 7.4 in x 2.7 in x 1.4 in (18.8 cm x 6.9 cm x 3.6 cm)
    Safety IEC 61010-1:2010; N10140

    EMC: IEC/EN61326-1:2006

    Certifications and Compliance     Conforms to relevant European Union                 directives     Conforms to relevant Australian standards    IEC/EN61010-1 CAN/CSA-C22.2 No. 1010.1-92 + CSA-C22.2 No. 1010.1B-97, UL/ANSI 3111-1