Add products to your Toolbox to save it for requesting a quote while you keep browsing for other products to complete your list.
# DSX2-8000 INT
Performance Specifications | ||
Category 8 test modes (or lower link categories) | ANSI/TIA-1152 Level 2G | |
Class I/II test modes | Proposed standard IEC 61935-1 Ed. 5 Level VI | |
Length of Twisted Pair Cabling1 | ||
Without Remote | With Remote | |
Range | 800 m (2600 ft) | 150 m (490 ft) |
Resolution | 0.1 m or 1 ft | 0.1 m or 1 ft |
Accuracy | ± (0.3 m + 2 %); 0 m to 150 m ± (0.3 m + 4 %); 150 m to 800 m |
± (0.3 m + 2 %) |
Propagation Delay | ||
Without Remote | With Remote | |
Range | 4000 ns | 750 ns |
Resolution | 1 ns | 1 ns |
Accuracy | ± (2 ns + 2 %); 0 ns to 750 ns ± (2 ns + 4 %); 750 ns to 4000 ns |
± (2 ns + 2 %) |
Delay Skew | ||
Range | 0 ns to 100 ns | |
Resolution | 1 ns | |
Accuracy | ± 10 ns | |
DC Loop Resistance Test | ||
Range | 0 Ω to 540 Ω | |
Resolution | 0.1 Ω | |
Accuracy | ± (1 Ω + 1 %) | |
Overload recovery time | Less than 10 minutes to rated accuracy following an overvoltage. Referencing is required after repeated or prolonged overvoltage. |
Product selected: Model #