Add products to your Toolbox to save it for requesting a quote while you keep browsing for other products to complete your list.
# TG 300
Measuring range | PE: pulse-echo mode 0.65 600 mm (steel) |
EE: echo-echo mode 2.50 60 mm | |
Accuracy | ± 0.04 mm H [mm] (<10 mm); ± 0.4% H [mm] (> 10 mm) |
H refers to the material thickness of the workpiece | |
Resolution | 0.1 mm / 0.01 mm / 0.001 mm (adjustable) |
Measurable materials | Metals |
Plastics | |
Ceramics | |
Epoxy resin | |
Glass | |
And all homogeneous materials | |
Working modes | Pulse echo mode (fault and blower detection) |
Echo-Echo mode (hiding layer thicknesses, eg paints) | |
Calibration | Sound velocity calibration |
Zeroing | |
Two-point calibration | |
View mode | Normal mode, Scan mode, Difference mode |
Units | mm / inch |
Data transfer | Print via Bluetooth / USB 2.0 |
Storage | Non-volatile memory with 100 data groups with 100 data sets each |
Operating time | Continuous operation 100 h |
Automatic stand-by mode (adjustable) | |
Automatic switch-off mode (adjustable) | |
Power supply | 4 x AA battery 1.5V |
Display | 320 x 240 pixels TFT LCD color display with brightness adjustment |
Operating conditions | 0 50°C / 32 122°F, ≤ 80% RH not condensing |
Storage conditions | -20 70°C / -4 158°F, ≤ 80% rh non-condensing |
Dimensions | 185 x 97 x 40 mm / 7.3 x 3.8 x 1.6 in |
Weight | 375 g / < 1 lb |
Specification of the available sensors for wall thickness gauge PCE-TG 300 | |
NO2 | |
Frequency | 2.5 MHz |
Diameter | 14 mm |
Measuring range | 3 40 mm (steel) |
3 300 mm (steel) | |
Minimum diameter of pipes | Not suitable for curved materials |
Description | For damping / scattering materials (plastics, cast iron) |
NO5 | |
Frequency | 5 MHz |
Diameter | 10 mm |
Measuring range | 1 600 mm (steel) |
Minimum diameter of pipes | 20 x 3 mm |
Description | Normal measurement |
NO5 / 90° | |
Frequency | 5 MHz |
Diameter | 10 |
Measuring range | 1 600 mm (steel) |
Minimum diameter of pipes | 20 x 3 mm |
Description | Normal measurement |
NO7 | |
Frequency | 7 MHz |
Diameter | 6 mm |
Measuring range | 0.65 200 mm (steel) |
Minimum diameter of pipes | 15 x 2 mm |
Description | Or thin-walled or heavily curved pipes |
HT5 | |
Frequency | 5 MHz |
Diameter | 12 mm |
Measuring range | 1 600 mm (steel) |
Minimum diameter of pipes | 30 mm |
Description | For high temperatures (max 300°C / 572°F) |
P5EE | |
Frequency | 5 MHz |
Diameter | 10 mm |
Measuring range | PE: 2 600 mm, EE: 2.5 100 mm |
Minimum diameter of pipes | 20 x 3 mm |
Description | Normal measurement and EE test |
Product selected: Model #
*Demonstrations can only be scheduled within the UAE