Add products to your Toolbox to save it for requesting a quote while you keep browsing for other products to complete your list.
# MWM 220
Measurement range | 0 to 100 % |
Limits of permissible absolute error of the measurements results of the mass fraction of water | Δ= 0,035 +0,05·W |
Temperature measurement range | -40 to +150 °C |
Range of working temperatures | -20 to +120 °C, -20 to +145 °C |
Operation mode | continuous operation |
Measurement period | 1 s |
Voltage supply – Rated / – Allowable | 24 (18 to 36) VDC |
Consumption current, not more than | 200 mA |
Warm-up time at start-up | 90 min |
Output | RS 485 Modbus RTU, 4-20 mA [RS485: max. cable length 1,000 m; 4-20 mA: max. cable length 100 m (max. cable length to SPS unit)] |
Pressure | PN 6 to PN 40 (to 100 bar ≙ 10 MPa) |
Dimension of the sensor | DN 50, DN 80, DN 100 or DN 125 (depending on the variant) / length allways 400 mm |
Overall dimension of the electric unit | 255 х 170 x 60 mm |
Protection class (sensor) | IP67 |
Protection class (electric unit) | IP66 (explosion-proof) |
mass Sensor | 9 to x kg (depending on wall thickness, pressure range) |
mass Electric unit | 2 kg |
mass Electric unit (explosion-proof) | 8 kg |
Product selected: Model #
*Demonstrations can only be scheduled within the UAE