Add products to your Toolbox to save it for requesting a quote while you keep browsing for other products to complete your list.
# LT 12
Measuring function | |||
AC | |||
Measuring range | Resolution | Accuracy | |
200 mV | 0.1 mV | ± (0.8% + 5 digits) | |
2V | 1 mV | ± (0.8% + 5 digits) | |
20V | 0.01V | ± (0.8% + 5 digits) | |
200V | 0.1V | ± (0.8% + 5 digits) | |
750V | 1V | ± (0.8% + 5 digits) | |
Maximum input voltage: 750V AC | |||
Frequency range: 40 … 400 Hz | |||
Conversion RMS | |||
DC | |||
Measuring range | Resolution | Accuracy | |
200 mV | 0.1 mV | ± (0.5% + 5 digits) | |
2V | 1 mV | ± (0.5% + 5 digits) | |
20V | 0.01V | ± (0.5% + 5 digits) | |
200V | 0.1V | ± (0.5% + 5 digits) | |
1000V | 1V | ± (0.8% + 5 digits) | |
Maximum input voltage: 1000V DC | |||
Alternating current | |||
Measuring range | Resolution | Accuracy | |
200 μA | 0.1 μA | ± (1.5% + 5 digits) | |
2000 μA | 1 μA | ± (1.5% + 5 digits) | |
20-mA | 0.01-mA | ± (1.5% + 5 digits) | |
200-mA | 0.1-mA | ± (1.5% + 5 digits) | |
2 A | 0.001 A | ± (3.0% + 5 digits) | |
20 A | 0.01A | ± (3.0% + 5 digits) | |
Overload protection at μA, mA: 200-mA / 1000V fuse | |||
Overload protection at A: 10 A / 500V fuse | |||
maximum input current μA: 2000 μA | |||
maximum input current mA: 200-mA | |||
maximum input current A: 10 A. | |||
Frequency range: 40 … 400 Hz | |||
Conversion RMS | |||
Measuring function | |||
Direct current | |||
Measuring range | Resolution | Accuracy | |
200 μA | 0.1 μA | ± (1.2% + 5 digits) | |
2000 μA | 1 μA | ± (1.2% + 5 digits) | |
20-mA | 0.01-mA | ± (1.2% + 5 digits) | |
200-mA | 0.1-mA | ± (1.2% + 5 digits) | |
2 A | 0.001 A | ± (2.0% + 5 digits) | |
20 A | 0.01A | ± (2.0% + 5 digits) | |
Overload protection at μA, mA: 200-mA / 1000V fuse | |||
Overload protection at A: 10 A / 500V fuse | |||
maximum input current μA: 2000 μA | |||
maximum input current mA: 200-mA | |||
maximum input current A: 10 A. | |||
Measuring function | |||
Resistance | |||
Measuring range | Resolution | Accuracy | |
200 Ω | 0.1 Ω | ± (1.0% + 5 digits) | |
2 kΩ | 0.001 kΩ | ± (1.0% + 5 digits) | |
20 kΩ | 0.01 kΩ | ± (1.0% + 5 digits) | |
200 kΩ | 0.1 kΩ | ± (1.0% + 5 digits) | |
2 MΩ | 0.001 MΩ | ± (1.0% + 5 digits) | |
20 MΩ | 0.01 MΩ | ± (1.0% + 5 digits) | |
Diode measurement | |||
Measuring range | Resolution | Accuracy | |
Indicates the forward voltage | 1 mV | – | |
Continuity test | |||
Measuring range | Resolution | Accuracy | |
Beep at <70 Ω | 0.1 Ω | – | |
Other specifications | |||
Range selection | Automatically and manually | ||
Measurement with receiver | Detecting cable bridges, detecting cable runs | ||
Measurement with network function | Detection of open and closed circuits, | ||
wrong connection, “split pair”, “reverse” connection, | |||
Network integration test, screening test | |||
Further measurement function | “NCV” detection, telephone connection testing | ||
Display | LCD, 1999 digits | ||
Overload indicator | “OIL” | ||
Automatic shutdown | After 15 minutes of inactivity | ||
Fuses | F10A / 500V, F200mA / 1000A | ||
Battery indicator | Display when battery is discharged | ||
Power supply | 9V block battery | ||
Operating conditions | 0 … 40°C / 32 … 104°F | ||
-10 … 50°C / 14 … 122°F | |||
Dimensions | 195 x 92 x 55 mm / 7.7 x 3.6 x 2.2 in | ||
Weight | Approx. 400 g / < 1 lb (with batteries) |