    PCE Instruments ET 5000 Earth Resistance Meter

    # ET 5000

    • Visual connection aid for easy operation
    • Alarm in case of incorrect connection of the measuring line
    • Direct and indirect resistance measurement
    • Interference currents, interference voltages, frequencies

     

    • The earth tester / earth resistance meter is a versatile ohmmeter. With this grounding meter a variety of resistance measurements can be performed. Thus, with the grounding meter, the possibility exists to perform a normal resistance measurement of 2- or 4-pole application. It is also possible to determine the resistance of the soil with the grounding meter. For the measurement of earth resistance corresponding earth spikes are included in the scope of supply. These ground spikes can easily be connected to the grounding device via the supplied separate 20 meter / 66 ft cable.
    • Another important measuring function is the measurement of the resistance of, for example, lightning conductors. This measurement is used to control the lightning conductors on, for example, schools or university buildings and is essential to derive a possible lightning strike into the ground. This earth tester / earth resistance meter can thus be used to determine whether the lightning rod is properly connected to the ground and whether it has the right resistance value to discharge a lightning bolt into the ground.
    • To ensure a perfect measurement, the earth tester / earth resistance meter has a measuring terminal detection. After the operator has set the grounding meter to the desired measurement function, the terminals to be used light up. If an incorrect connection has been selected by the operator, the grounding meter signals the operator both acoustically and visually. At the same time, the measurement by the grounding meter is refused until the test setup has been properly connected. This massively limits faulty measurements by the intelligent grounding meter. Also, the grounding device has a memory. This allows the measurement data from the grounding meter to be transferred to a PC and evaluated after a measurement.
    • With the grounding meter, the possibility exists to perform a normal resistance measurement of 2- or 4-pole application. It is also possible to determine the resistance of the soil with the grounding meter.
    • For the measurement of earth resistance corresponding earth spikes are included in the scope of supply. These ground spikes can easily be connected to the grounding device via the supplied separate 20 meter / 66 ft cable.
    • Mobile use thanks to battery and batteries
    • Data memory for later analysis on the PC
    • Visual connection aid for easy operation
    • Alarm in case of incorrect connection of the measuring line
    • Direct and indirect resistance measurement
    • Interference currents, interference voltages, frequencies
    Data storage100 readings
    Operating conditions0 to 40°C / 32 to 104°F, < 80% RH (non-condensing)
    Charge ambient conditions to the battery10 to 40°C / 50 to 104°F, < 80% rh (non-condensing)
    Storage conditions-10 to 50°C / 50 to 122°F, < 90% rh (non-condensing)
    Storage conditions for the battery-20 to 30°C / -4 to 86°F, < 80% rh (non-condensing)
    Storage height< 12,000 m / 39,370 ft
    Operating altitude< 2,000 m / 6,561 ft
    Clamp diameter51 mm
    DisplayBacklit LCD, 9,999 digits
    Display measuring range exceeded> LIMIT
    Display below measuring range
    Measuring frequency earthing resistance / leakage current1 Hz (If the average value function is activated: one value every four seconds)
    Measuring frequency voltage measurement2 Hz
    Measuring frequency interference voltage4 Hz
    Measuring frequency interference frequency1 Hz
    Measuring frequency interference current1 Hz
    InterfacesMeasuring connection: E, ES, S, H, pliers connection USB-B, charging connection
    Power supply batteries6 x 1.5V D LR14 batteries
    Power supply battery1 x 7.2V nickel-metal hydride battery pack
    Power supply power supply (Primary)100 to 240V, 50 to 60 Hz
    Power supply power supply (Secondary)12V, 3A
    Max. Power consumption with power supply15V A
    Max. Power consumption with battery or rechargeable battery6V A
    Running time in battery modeAbout 5 hours
    Running time in the batteryAbout 9 hours (without backlight)
    Maximum input voltage relative to earth300V rms (CAT III)
    Insulation thickness6880V AC: 15 seconds
    Overvoltage protection250V AC between the connections
    Dimensions260 x 125 x 280 mm / 10.2 x 4.9 x 11 in
    WeightAbout 2.5 kg / 5.5 lbs
    Standardize (Safety)EN61010-1: 2001, EN61010-031: 2002 Pollution degree 2, CAT III 300V
    Standardize (EMC)EN61000-3-2: 2000, IEC61326-1: 1997 A
    • 1 x Earth Tester / Earth Resistance Meter PCE-ET 5000
    • 4 x Crocodile clips
    • 1 x Power supply
    • 1 x USB cable
    • 4 x Test cable
    • 1 x Voltage terminal cable
    • 1 x Power terminal cable
    • 6 x 1.5V C batteries
    • 2 x Current clamps
    • 1 x Rechargeable Ni-MH battery
    • 4 x Insert samples
    • 1 x User manual