Add products to your Toolbox to save it for requesting a quote while you keep browsing for other products to complete your list.
# DC 10
This product has been discontinued by the manufacturer.
Alternate products: Gazelle G9205, Fluke 324, Fluke 325.
AC power | ||
measuring range | Resolution | Accuracy |
2 A | 0.01A | ± (2.5% + 8 digits) |
20 A | 0.01A | ± (2.5% + 8 digits) |
200 A | 0.1 A | ± (2.5% + 8 digits) |
600 A | 1 A | ± (3.0% + 10 digits) |
Frequency range: .45 … 65 Hz | ||
The freqeuence is only displayed from a current of 0.2A. | ||
maximum input current: up to 600 A for no more than 60 seconds. | ||
Accuracy refers to RMS sine waves. | ||
AC voltage | ||
measuring range | Resolution | Accuracy |
6V | 0.01V | ± (0.8% + 5 digits) |
60V | 0.1V | |
600V | 1 V | |
Input impedance: 10 MΩ | ||
Overvoltage protection 600V AC / DC rms | ||
Smallest measurable voltage: 1V AC / DC | ||
Frequency range: 45 … 65 Hz | ||
Accuracy refers to RMS sine waves | ||
If a current is detected during the voltage measurement, “Err” appears on the display | ||
DC voltage | ||
measuring range | Resolution | Accuracy |
6V | 0.01V | ± (0.5% + 3 digits) |
60V | 0.1V | |
600V | 1 V | |
Input impedance: 10 MΩ | ||
Overvoltage protection 600V AC / DC rms | ||
Smallest measurable voltage: 1V AC / DC | ||
Resistance | ||
measuring range | Resolution | Accuracy |
2 kΩ | 0.001 kΩ | ± (0.8% + 3 digits) |
20 kΩ | 0.01 kΩ | ± (0.8% + 3 digits) |
200 kΩ | 0.1 kΩ | ± (0.8% + 3 digits) |
2 MΩ | 0.001 MΩ | ± (0.8% + 3 digits) |
10 MΩ | 0.01 MΩ | ± (1% + 5 digits) |
Measuring voltage in open circuit: approx. 0.4V | ||
Overvoltage protection: 250V AC / DC rms | ||
Continuity test | ||
Beep at < 40 Ω | ||
Measuring voltage in open circuit: approx. 0.4V | ||
Overvoltage protection: 250V AC / DC rms | ||
Frequency | ||
measuring range | Resolution | Accuracy |
60 Hz | 0.1 Hz | ± (1% + 5 digits) |
600 Hz | 1 Hz | |
3 kHz | 10 Hz | |
Total measuring range: 40 … 3 kHz | ||
Minimum voltage: > 1 AC RMS (The measurement frequency will increase with the voltage) | ||
Overvoltage protection: 600V AC / DC rms | ||
Duty cycle | ||
measuring range | Resolution | Accuracy |
10 … 90% | 1% | ± 2% |
Maximum current clamp Opening | 26 mm | |
Insulation | CAT III 600V | |
Measuring rate | About 3 measurements per second | |
Display | 3 5/6 digit LCD | |
Display area | 5999, 1999 for resistance measurement | |
Measurement outside the Measuring range | “OL” display | |
Automatic shutdown | After 15 minutes, can be deactivated | |
Coefficients | 0.1 x accuracy x °C / °F* | |
Power supply | 3 x 1.5V AAA batteries | |
Operating conditions | 0 … 40°C / 32 … 104°F, < 80% rh | |
Storage conditions | -10 … 60°C / 14 … 140°F, < 70% rh (without batteries) | |
Maximum working height | 2000 m / 6561 ft | |
Dimensions | 204 x 78 x 43 mm / 8 x 3.1 x 1.7 in | |
Weight | About 195 g / < 1 lb | |
Accuracies are given at ambient conditions of 18 … 28°C, 65 … 83°F. *The temperature is the difference between the temperature of the operating conditions and the current ambient temperature. |
Product selected: Model #