• Store Locator
  • Schedule a
    Demo
  • Add products to your Toolbox to save it for requesting a quote while you keep browsing for other products to complete your list.

    My
    Toolbox
  • PCE Instruments 830-3 Three-Phase Power Analyzer

    # 830-3

    • Measures parameters such as voltage, current, frequency, harmonics, and power as well as indicating, according to standard EN50160, harmonic values, interharmonics, and asymmetrics.
    • Interference, such as interruptions, leaks, overloads, or transience (from 16 µs) are detected with their corresponding values.
    • The backlit LCD, with high resolution, can show up to 35 parameters simultaneously. Up to 3 clips can be attached at the same time to the Power Analyzer.
    • The PCE-830 Power Analyzer is used for measuring one to three phases of electrical quantities for alternating current (AC). This Power Analyzer also measures parameters such as voltage, current, frequency, harmonics, and power as well as indicating, according to standard EN50160, harmonic values, interharmonics, and asymmetrics. Interference, such as interruptions, leaks, overloads, or transience (from 16 µs) are detected with their corresponding values. The backlit LCD, with high resolution, can show up to 35 parameters simultaneously. Up to 3 clips can be attached at the same time to the Power Analyzer. In data logger mode, it can save up to 17,470 readings (3 phases / 4 conductors), in a simpler set up (1 phase / 2 conductors) it can save up to 52,400 readings, split into 85 groups. All this makes the PCE-830 Power Analyzer the ideal instrument for taking measurements over long durations. Measurement values obtained can be sent to a computer and be processed with the included analysis software. The device comes with everything needed to be measuring and analyzing from the moment it arrives. Although the Power Analyzer comes calibrated from the manufacturer, an optional laboratory calibration and certificate, that meets ISO standards, can be ordered separately with the device or when a recalibration is required.
    • Analysis of a network of 3 phases / 4 conductors, 3 phases / 3 conductors, 1 phase / 2 conductors, 1 phase / 3 conductors
    • Measures effective real value (V 123 and I 123)
    • Measures active power (W, KW, MW, GW)
    • Measures apparent and reactive power (KVA, KVAR)
    • Power Factor (PF), phase angle (Φ)
    • Measures energy and work (Wh, KWh, KVARh, PFh)
    • Measures current from 0.1 mA to 3000 A, allowing for the reserve power of a factory to be determined
    • Large LCD that shows up to 35 parameters simultaneously (3P4W [=3 phases/4 conductors])
    • CT conditions (1 to 600) and PT (1 to 3000) are programmable
    • Indicates current wave forms and voltage overlap.
    • 512 KB of memory with programmable intervals to save data every 2 to 3000 seconds, 17,470 readings using the system of 3 phases / 4 conductors
    • Indicates wave forms, efficiency parameters, and harmonic distortion
    • Backlit LCD with dot matrix
    • Average power (AD in W, KW, MW)
    • Maximum power (MD in W, KW, MW) with the programmable period
    • Analysis of harmonic distortion up to a curvature of 99
    • Indication of up to 50º form of harmonic wave
    • Indication of the wave form with maximum value (1024 readings / period)
    • Analysis of absolute distortion (%THD-F)
    • Diagram of graphic equilibrium with parameters of a 3 phase system
    • Detects up to 28 transistors (time and cycles) with a programmable threshold (%)
    • Relation of 3 phases of voltage or asymmetrical current (VUR)
    • Factor of 3 phases of voltage and asymmetrical current (d0%, d2%)
    • USB port (optically insulated)
    • Integrated timer and calendar to record data
    • Maximum diameter of the electrical conductor for the amp clamp: the PCE-6801 ~30 mm / 1.2 in, PCE-6802 ~55 mm / 2.2 in, PCE 3007 ~170 mm / 6.7 in
    Technical Specifications
    Measurement valuesMeasurement ranges / resolution / accuracy
    PCE-830 + PCE-3007
    Watts AC (50 Hz or 60 Hz, PF 0.5 up to 1)
    10.0 W to 999.9 W / 0.1 W / ±1% of measurement range
    1.000 kW to 9.999 kW / 0.001 kW / ±1% of measurement range
    10.00 kW to 99.99 kW / 0.01 kW / ±1% of measurement range
    100.0 kW to 999.9 kW / 0.1 kW / ±1% of measurement range
    1000 kW to 9999 kW / 1 kW / ±1% of measurement range
    PCE-830 + PCE-3007
    Current AC (50 Hz or 60 Hz, auto range select, TRMS)
    0 to 300 A / 0.1 A / ±1.0% of measurement range
    300.0 A to 999.9 A / 0.1 A / ±1.0% of measurement range
    1000 A to 3000 A / 1 A / ±1.0% of measurement range
    Voltage AC (50 Hz or 60 Hz, TRMS)20.0 V to 500.0 V / 0.1 V / ±0.5% ±5 digits
    (measure between phase and neutral)
    20.0 V to 600.0 V / 0.1 V / ±0.5% ±5 digits
    (measure between phase and neutral)
    Harmonic distortion of AC voltage1º to 20º / 0.1% / ±1.0%
    21º to 49º / 0.1% / 4% of reading ±2.0%
    50º to 99º / 0.1% / 6% of reading ±2.0%
    PCE-830 + PCE-3007
    Harmonics 
    of AC current in %
    1º to 10º / 0.1% / ±2%
    21º to 49º / 0.1% / ±6%
    50º to 99º / 0.1% / ±10%
    PCE-830 + PCE-3007
    Power Factor (PF)
    0.000 to 1.000 / 0.001 / ±0.04
    PCE-830 + PCE-3007
    Phase angle (Phi)
    0° to 180° / 0.1° / ±2°
    PCE-830 + PCE-3007
    Total harmonic distortion
    0.0 to 20.0% / 0.1% / ±2%
    20.0% to 100% / 0.1% / ±6% of reading ±1%
    100% to 999.9% / 0.1% / ±10% of reading ±1%
    Maximum measurement of AC voltage and current50 Hz / 19 µS / ±5% ±30 digits
    60 Hz / 16 µS / ±5% ±30 digits
    Peak value measurement of AC voltage and current1.00 to 99.99 / 0.01 / ±5% ±30 digits
    Frequency range in automatic mode45 Hz to 65 Hz / 0.1 Hz / 0.1 Hz
    Memory512 kB for a maximum 52,420 readings taken by 1 phase / 2 conductors
    PortUSB
    Software and cableIncluded, for Windows 2000, XP, ME
    DisplayBacklit LCD with dot matrix
    Power8 AA batteries (Mignon)
    Dimensions257 mm x 155 mm x 57 mm
    10.1 in x 6.1 in x 2.2 in
    Weight1.16 kg / 2.56 lbs
    Operating conditionsMax. 85% relative humidity
    -10º C to 50º C / +14º F to +122º F
    Type of protection / standardsIEC 61010, 600 V/CAT III
    • 1 x PCE-830-3 Power Analyzer
    • 3 x Amp clamps – PCE-3007
    • 4 x Alligator clips
    • 4 x Safety test lines (3 m / 3.3 ft long),
    • 8 x Batteries
    • 1 x Mains adaptor
    • 1 x Carrying case
    • 1 x USB cable software
    • 1 x User’s manual

    Provide us your contact detailsone of our product experts will contact you to discuss your needs or schedule a demonstration at a time that suits

    Product selected: Model #







      *Demonstrations can only be scheduled within the UAE

      Sign up to stay in the know-how of our latest products, updates, special offers, and more.

      • Subscription Form