# 787B
The Fluke 787B ProcessMeter™ doubles troubleshooting capabilities by combining the power of a safety rated digital multimeter and mA loop calibrator into a single, compact test tool. Based on the trusted measurement capabilities of the Fluke 87 DMM, the 787B adds the ability to measure, source and simulate mA with the accuracy and resolution you would expect from a Fluke mA loop calibrator, giving you the ideal tool for troubleshooting and calibrating current loop applications. With Fluke Connect® mobile app and desktop software compatibility technicians can wirelessly monitor, log, and share data from the field with their team anytime, from anywhere*.
Measurement function | Range and resolution | Best accuracy (% of reading + LSD) | |
V dc | 400.0 mV, 4.000 V, 40.00 V, 400.0 V, 1000 V | 0.1% + 1 | |
V ac (true-rms) | 400.0 mV, 4.000 V, 40.00 V, 400.0 V, 1000 V | 0.7% + 2 | |
mA dc | 30.000 mA | .05% + 2 | |
A dc | 1.000 A (0.440 A continuous) | 0.2% + 2 | |
A ac | 1.000 A (0.440 A continuous) | 1% + 2 | |
Resistance | 400.0 Ohms, 4.000 k, 40.00 k, 400.0 k, 4.0 M, 40 M | 0.2% + 1 | |
Frequency (0.5 Hz to 20 kHz) | 199.99 Hz, 1999.9 Hz, 19.999 kHz | .005% + 1 | |
Diode test | 2.000 V (shows diode voltage drop) | 2% + 1 | |
Continuity | Beeps for resistance < approx. 100 ohms | ||
Output function | Range and resolution | Drive capability | Accuracy (% of span) |
DC current output (Internal battery operation) | 0.000 to 20.000 mA or 4.000 to 20.000 mA, (selectable at power-up) Over-range to 24.000 mA | 24 V compliance or, 1,200 ohms, @ 20 mA | 0.05% |
DC current simulate (Ext. 15 V to 48 V loop supply) | 0.000 to 20.000 mA or 4.000 to 20.000 mA, (selectable at power-up) Over-range to 24.000 mA | 1000 ohms, @ 20 mA | 0.05% |
Current adjustment modes | Manual: Coarse, Fine, 25% and 100% step | ||
Automatic: Slow Ramp, Fast Ramp, 25% step | |||
Temperature range of 18 °C to 28 °C, for one year after calibration | |||
General specifications | |||
Maximum voltage applied between any jack and earth ground | 1000 V RMS | ||
Storage temperature | -40 °C to 60 °C | ||
Operating temperature | -20 °C to 55 °C | ||
Temperature coefficient | 0.05 x (specified accuracy) per °C (for temperatures < 18 °C or > 28 °C) | ||
Relative humidity | 95% up to 30 °C; 75% up to 40 °C; 45% up to 50 °C; 35% up to 55 °C | ||
Vibration | Random, 2 g, 5-500 Hz | ||
Shock | 1 meter drop test | ||
Safety | IEC61010-1, Pollution Degree 2/IEC61010-2-033, CAT IV 600 V/CAT III 1000 V | ||
Size (HxWxL) | 50 x 100 x 203 mm (1.97 x 3.94 x 8.00 in) | ||
Weight | 600 g (1.3 lbs) | ||
Battery | Four AA alkaline batteries | ||
Battery life | 140 hours typical (measurement), 10 hours typical (sourcing 12 mA) |