    FLUKE BT520 Battery Analyzer 26.5 x 13.4 x 10.1 inches

    # BT520

    • Measure the voltage of the battery under test
    • Measures unwanted residual ac component of the rectified voltage in dc charging and inverter circuits.
    • Measures the resistance of the intercell connection between batteries in a string.
    FLUKE
    • FLUKE
    • BT520

    Ready to see it in action? Please provide us with your contact information, and one of our technical experts will contact you to schedule your product demonstration.

    Reduced testing complexity, a simplified workflow and an intuitive user interface provide a new level of ease-of-use in battery testing.

    • The ideal test tool for maintenance, troubleshooting and performance testing of individual stationary batteries and battery banks used in critical battery back-up applications
    • The intuitive user interface, compact design and rugged construction ensure optimum performance, test results and reliability
    • Covers a broad range of battery test functions ranging from DC voltage and resistance tests to full condition testing using automated string function testing and the test probe integrated infra-red temperature measurement system
    • Designed for measurements on stationary batteries of all types.

    Voltage and Resistance Thresholds

    Fluke Battery Analyzers allow you to quickly and easily define upper and lower measurement thresholds or tolerance ranges. During the testing process, measured values are automatically compared to the predefined threshold levels producing a PASS, FAIL or WARN indication after each measurement. A maximum of 10 sets of thresholds can be stored and threshold indications are determined based on the following criterion:

    Voltage Resistance
    > Voltage Lower < Voltage Lower < Reference > Reference and Reference x (1+Warning %) > Reference x (1+Fail)
    Pass Fail Pass Warning Fail

    Fluke Battery Management Software

    Fluke Battery Management Software Easily allows you to quickly and easily import data from the battery analyzer to a PC. The measurement data and battery profile information is stored and archived with the Management Software and can be used compare results, switch results between conductance and resistance readings and perform trend analysis. All measurement data, battery profile and analysis information can be used to easily generate reports.

    • Quick view saved readings
    • Profile management
    • Histogram of a battery string with end user defined threshold
    • Historical trend data of batteries
    • Multiple rounds of discharge voltage
    • Quick Report Generation
    • Upgrade Fluke Battery Analyzer firmware
    • Switch measurement results between conductance and resistance readings

    Fluke Battery Analyze mobile app

    The BT521 offers wireless communication for data download and remote display while measuring via the dedicated Fluke Battery Analyzer mobile app (note: the Fluke BT521 is not currently Fluke Connect compatible). Using the Fluke Battery Analyze mobile app you can:

    • Browse profile
    • Review sequence testing data
    • E-mail sequence testing data

    Fluke BT500 key features:

    • Battery Voltage – During the internal resistance test, Fluke Battery Analyzers also measure the voltage of the battery under test
    • Discharge Volts – The Discharge mode collects the voltage of each battery multiple times at a user defined interval during a discharge or load test. Users can calculate the time a battery takes to drop to the cut-off voltage and use this time to determine the capacity loss of the battery
    • Ripple Voltage Test – Measures unwanted residual ac component of the rectified voltage in dc charging and inverter circuits. Allows users to test ac components in dc charging circuits and find one of the root causes of battery deterioration
    • Meter and Sequence Modes – The Meter mode is used for a quick test or troubleshooting. In this mode you can save and read the readings in a measurement or time sequence. The Sequence mode is for maintenance tasks with multiple power systems and battery strings. Before a task starts, users can configure a profile for the task for data management and report generation
    • Threshold and Warning – Users can configure a maximum of 10 sets of thresholds and receive a Pass/ Warning/ Fail indication after each measurement
    • Intercell Strap Resistance Test and Data Management – Measures the resistance of the intercell connection between batteries in a string.
    • AutoHold – When AutoHold is turned on, a reading is captured when it remains stable for 1 second. The reading is then released when a new measurement starts
    • AutoSave – When AutoSave is turned on, measured values are saved to internal memory automatically after an AutoHold reading is captured
    • Fluke Battery Management Software – Easily import data from the Product to a PC. The measurement data and battery profile information is stored and archived with the Management Software and can be used for comparison and trend analysis. All measurement data, battery profile and analysis information can be used to easily generate reports
    • Comprehensive logging – All measured values are automatically captured during testing and can be reviewed on the instrument before downloading for on the-go analysis
    • Optimized user interface – Quick, guided setup ensures you’re capturing the right data every time
    • Battery life – 7.4 V 3000 mAh lithium-ion battery for more than eight hours continuous operation.
    • USB port – For fast data download to supplied data analysis and report management application software.
    • Highest safety rating in the industry – CAT III 600 V, 1000 V dc max. rated for safe measurements all around the battery power supply equipment.

    Fluke BT520 Key features: (Designed for measuring batteries in cabinets and hard to reach places)

    • All of the above plus
    • BTL20 Intelligent Test Probe set, with long and short probe extenders and built-in LCD display and speaker for visual and audio feedback
    • BTL20ANG Intelligent Test Probe Set, with long and short angled tip probe extenders (no temperature sensor)
    • Large soft carry case
    Range Resolution Accuracy BT510 BT520 BT520ANG BT521 BT521ANG
    Battery Resistance / Strap Resistance1 3 mΩ 0.001 mΩ 1% + 8
    1% +68
    30 mΩ 0.01 mΩ 0.8% + 6
    0.8%+12
    300 mΩ 0.1 mΩ 0.8% + 6
    3000 mΩ 1 mΩ 0.8% + 6
    VDC 6 V 0.001 V 0.09% + 5
    60 V 0.01 V 0.09% + 5
    600 V 0.1 V 0.09% + 5
    1000 V 1 V 0.09% + 5
    VAC (45 Hz to 500 Hz with 800 Hz filter) 600 V 0.1 V 2% + 10
    Frequency (displayed with VAC and AAC)2 500 Hz 0.1 Hz 0.5% + 8
    AC voltage ripple (20 KHz  Max) 600 mV 0.1 mV 3% + 20
    6000 mV 1 mV 3% + 10
    ADC/AAC (with accessory Fluke i410) 400 A 1 A 3.5% + 2
    Temperature 0°C to 60°C 1°C 2°C (4°F)
    Meter mode 999 records for each measurement position with time stamp
    Sequence mode Up to 100 profiles and 100 profile templates (Each profile stores up to 450 batteries) with time stamp
    1. The measurement is based on AC injection method. The injected source signal is < 100 mA, 1 kHz.
    2. Trigger level VAC: 10 mV, AAC: 10 A
    Measurement Modes BT510 BT520 BT521
    Resistance (mΩ)
    Battery voltage
    Voltage DC
    Voltage AC and frequency  (Hz)
    Ripple volt
    Temperature of negative battery post (using BTL21 straight probes)
    DC and AC current (and frequency)
    DMM mode
    Sequence mode
    Discharge measurement mode
    Automatic measurement  save
    Wireless commumcation
    Memory view
    General Specifications – Battery Analyzer
    Size (H x W x D) 22 x 10.3 x 5.8 cm (9 x 4 x 2 in)
    Weight 850 g (1.9 lb)
    Screen dimensions 7.7 x 5.6 cm (3 x 2.2 in)
    Interface USB mini
    Warranty 3 years
    General Specifications – BTL20ANG Angled Measurement Probe
    Long angled probe (overall length) 242.2 cm (95.38 in)
    Short angled probe (overall length) 216.8 cm (85.38 in)
    Overall span (coil relaxed) 10.1 cm (4 in)
    Overall maximum span (coil extended) 109.2 cm (43 in)
    BTL20ANG probe tip angle 20 degrees from horizontal
    Environment Specifications
    Operating temperature 0°C to 40°C
    Storage temperature -20°C to 50°C
    Lithium-ion  battery charging temperature 0°C to 40°C
    Operating humidity Non-condensing (10°C)
    ≤ 80% RH (at 10°C to 30°C)
    ≤ 75% RH (at 30°C to 40°C)
    Operating altitude Sea level to 2000 meters
    Storage altitude Sea level to 12,000 meters
    IP rating IP40
    Radio FCC Class A
    Vibration  requirements MIL-PRF-28800F: Class 2
    Drop test  requirements 1 meter
    Temperature coefficients Add 0.1 x specified accuracy for each degree C above 28°C or below 18°C
    Safety  compliance 600 V CAT III
    EMC IEC 61326
    ROHS China, Europe
    Protection class 2 Pollution Degree II
    Battery compliance UN38.3
    UL2054
    IEC62133
    2 G per IEC68-2-26, 25 G, and 29
    • Battery analyzer
    • 4-wire test pin (set)
    • BTL10 Basic Test Lead (set)
    • TL175 TwistGuardª Test Leads with adapter
    • BTL20 Intelligent Test Probe Set, with extender (no temperature sensor)
    • BP500 lithium-ion battery
    • BC500 AC charger
    • mini-USB cable
    • Shoulder strap
    • Belt strap
    • Magnetic hanging strap
    • FlukeView¨ Battery Management Software
    • Soft carrying case
    • Spare fuses (2)
    • Battery tags
    • Zero Ohm Calibration Resistor

    Explore More in Battery Analyzers

    Provide us your contact detailsone of our product experts will contact you to discuss your needs or schedule a demonstration at a time that suits

    Product selected: Model #







    *Demonstrations can only be scheduled within the UAE

    Sign up to stay in the know-how of our latest products, updates, special offers, and more.

    • Subscription Form