• Store Locator
  • Schedule a
    Demo
  • Add products to your Toolbox to save it for requesting a quote while you keep browsing for other products to complete your list.

    My
    Toolbox
  • expression

    FLUKE 975V AirMeter with Velocity

    # 975V

    • CO2; CO; temperature; humidity; air velocity; MIN/MAX/AVG; backlight; alarms; datalogging with software/USB
    • Optimize HVAC ventilation settings for ASHRAE 62 recommendations
    • Includes Air Velocity Probe
    FLUKE
    • FLUKE
    • 975V

    Quantity:

    - +
      ADD TO MY TOOLBOX
    Where to buy this product?

    The Fluke 975 offers an unparalleled featureset for HVAC and facilities technicians, helping them work more quickly and accurately, with the ease of use and durability customers expect from a Fluke meter.

     

    • Simultaneously measures, logs, and displays temperature, humidity, CO 2 , and CO on a bright, backlit LCD display
    • One-touch air flow and velocity with available probe*
    • Wet bulb and dew point temperature
    • % of outside air calculation
    • CO 2 and CO field calibration feature
    • Self-test function at startup
    • Auto-backlight
    • Automatically compensates for barometric pressure changes
    • Min/Max/Average on all measured and calculated readings
    • Multi-language user interface
    • Metric or standard units
    • Audible and visual threshold alarms
    • Extensive discrete or continuous data logging capacity, downloadable to PC via USB interface
    • Keypad lock for security
    • Included FlukeView Forms® software
    Measured Specifications
    Temperature Range -20°C to 50°C (-5°F to 122°F)
    Display resolution 0.1°C (0.1°F)
    Accuracy ±0.9°C / ±1.62°F from 40°C to 60°C
    ±0.5°C / ±1.00°F from 5°C to 40°C
    ±1.1°C / ±1.98°F from -20°C to 5°C
    Relative humidity Range 10% to 90% RH, non-condensing
    Display Resolution 1%
    Accuracy ±2% RH (10% RH to 90% RH)
    Air velocity Range 50.0 fpm to 3000 fpm
    0.25 m/sec to 15 m/sec
    Display Resolution 1 fpm (0.005 m/sec)
    Accuracy ±4% or 4 fpm1
    ±4% or 0.02 m/sec1 whichever is greater
    1. Accuracy specification only valid for velocity readings above 50 fpm.
    C0 Range 0 to 500 ppm
    Display Resolution 1 ppm
    Accuracy ±5% or ±3 ppm, whichever is greater, @ 20°C and 50% RH
    C02 Range 0 to 5000 ppm
    Display Resolution 1 ppm
    Accuracy Warm up time 1 min (5 minutes for full specification) 2.75% + 75 ppm
    Calculated Specifications
    Dew point temperature Range -44°C to 50°C, (-47°F to 122°F)
    Display Resolution 0.1°C (0.1°F)
    Accuracy ±1°C when temp: -20°C to 50°C RH: 40% to 90%
    ±2°C when temp: -20°C to 50°C RH: 20% to 40%
    ±4°C when RH: 10% to 20%
    Wet bulb temperature Range -16°C to 50°C, (3°F to 122°F)
    Display Resolution 0.1°C, (0.1°F)
    Accuracy ±1.2°C when RH: 20% to 90% temp: -20°C to 60°C
    ±2.1°C when RH: 10% to 20%
    Volume flow rate (in a duct) Range 0 to 3,965 M3/m, (0 to 140,000 cfm)
    Display Resolution 0.001 M3/min, (1 cfm)
    Accuracy N/A: The volume flow calculation will be a simple average of the data points times the duct area
    % outside air (based on temperature) Range 0 to 100%
    Display Resolution 0.1
    % outside air (based on CO2) Range 0 to 100%
    Display Resolution 0.1% N/A
    General Specifications
    Operating and storage temperature -20°C to 50°C (-4°F to 122°F)
    Humidity 10% to 90% (non-condensing)
    Altitude Up to 2000 m (6562 ft)
    Shock and vibration MIL-PRF-28800F: Class 2
    Multi-language interface English, French, Spanish, Portuguese and German
    Battery Rechargeable Li-Ion (primary), three-AA (backup)
    Data logging 25,000 records (continuous), 99 records (discrete)
    Manufacturer Warranty Two-years
    • 3 x AA alkaline batteries
    • users manual
    • calibration cap
    • FlukeView Forms software
    • USB cable
    • power adapter and carry case.

    Provide us your contact detailsone of our product experts will contact you to discuss your needs or schedule a demonstration at a time that suits

    Product selected: Model #







    *Demonstrations can only be scheduled within the UAE