• Store Locator
  • Schedule a
    Demo
  • Add products to your Toolbox to save it for requesting a quote while you keep browsing for other products to complete your list.

    My
    Toolbox
  • expression

    FLUKE 438-II-INTL Power Quality & Motor Analyzer

    # 438-II-INTL

    • Measure key parameters on direct-on-line motors and motors driven by specific variable frequency drive systems including torque, RPM, mechanical power and motor efficiency
    • Perform dynamic motor analysis by plotting of motor derating factor against load according to NEMA/IEC guidelines
    • Calculate mechanical power and efficiency without the need of mechanical sensors, just connect to the input conductors and you’re ready to go
    FLUKE
    • FLUKE
    • 438-II-INTL

    Quantity:

    - +
      ADD TO MY TOOLBOX
    Where to buy this product?

    Ready to see it in action? Please provide us with your contact information and one of our product experts will contact you to discuss your needs or schedule a demonstration at a time that suits.

    Schedule my demo
    • Measure key parameters on direct-on-line motors and motors driven by specific variable frequency drive systems including torque, RPM, mechanical power and motor efficiency
    • Perform dynamic motor analysis by plotting of motor derating factor against load according to NEMA/IEC guidelines
    • Calculate mechanical power and efficiency without the need of mechanical sensors, just connect to the input conductors and you’re ready to go
    • Measure electrical power parameters such as voltage, current, power, apparent power, power factor, harmonic distortion and unbalance to identify characteristics that impact motor efficiency
    • Identify power quality issues such as dips, swells, transients, harmonics and unbalance
    • PowerWave data technology captures fast RMS data, and shows half-cycle averages and waveforms to characterize electrical system dynamics (generator start-ups, UPS switching etc.)
    • Waveform capture function captures 100/120 cycles (50/60 Hz) of each event detected, in all modes, without set-up
    • Automatic transient mode captures waveform data at 200 kS/s on all phases simultaneously up to 6 kV
    • Fluke Connect¨ compatible* Ð view data locally on the instrument, via Fluke Connect mobile app and PowerLog 430-II desktop software
    • Safety rated for industrial applications 600 V CAT IV/1000 V CAT III rated for use at the service entrance and downstream
    Drive Measurement Details
    Motor Type 3 phase asynchronous (induction)
    Power Source Variable Frequency Drive
    Motor Frequency Range 40Hz to 70Hz
    Over/Under Voltage from Nominal V/f Curve (%) -15% to +15%
    Carrier Frequency Range 2.5kHz–20kHz
    Variable speed drive technology that is covered by the 438-II
    Inverter Type VSI only (voltage controlled) *
    Control Method V/f control, open-loop vector, closed loop vector, drives with encoders.
    Frequency 40 to 70 Hz
    * VSI drives are the most common drives. The alternative CSI drives are used in higher power applications.
    Variable speed drive technology NOT covered by the 438-II
    Inverter Type CSI (current source inverter)
    Motors type Synchronous (DC, stepper, permanent magnet etc.)
    Motor Frequency <40 and >70 Hz
    Mechanical specifications
    Mechanical measurements can be performed on direct online motors with a 3 wire connection.
    Motor measurement
    Range Resolution Accuracy Default limit
    Mechanical motor

    Power

    0.7 kW to 746 kW

    1 hp to 1000 hp

    0.1 kW

    0.1 hp

    ±3% 1

    ±3% 1

    100% = rated power

    100% = rated power

    Torque 0 Nm to 10 000 Nm

    0 lb ft to 10 000 lb ft

    0.1 Nm

    0.1 lb ft

    ±5% 1

    ±5% 1

    100% = rated torque

    100% = rated torque

    rpm 0 rpm to 3600 rpm 1 rpm ±3% 1 100% = rated rpm
    Efficiency 0% to 100% 0.10% ±3% 1 NA
    Unbalance (NEMA) 0% to 100% 0.10% ±0.15% 5%
    Harmonics Voltage
    Factor (NEMA)
    0 to 0.20 0.1 ±1.5% 0.15
    Unbalance Derating
    Factor
    0.7 to 1.0 0.1 indicative NA
    Harmonics Derating
    Factor
    0.7 to 1.0 0.1 indicative NA
    Total NEMA Derating
    Factor
    0.5 to 1.0 0.1 indicative NA
    Notes: Supports motor design types NEMA A, B, C, D & E and IEC type H and N.
    Rated torque is calculated from rated power and rated speed.
    Update rate of Motor Measurements is 1x per second.
    Default Trend duration is 1 week.
    1Add 5% error when selecting Motor design type Other
    Specification valid for Motor Power > 30% of rated power
    Specification valid at stable operating temperature. Run the motor for at least 1 hour at full load
    (2-3 hours if the motor is 50 HP or higher) to obtain stable temperature
    Product Specifications
    Volt Model Measurement Range Resolution Accuracy
    Vrms (AC + DC) 1 V to 1000 V phase to neutral 0.01 V ±0.1% of nominal voltage 1
    Vpk 1 Vpk to 1400 Vpk 1 V 5% of nominal voltage
    Voltage Crest Factor (CF) 1.0 > 2.8 0.01 ±5%
    Vrms½ 0.1 V ±0.2% of nominal voltage
    Vfund 0.1 V ±0.1% of nominal voltage
    Amps (AC + DC) i430-Flex 1x  5 A to 6000 A 1 A ±0.5% ±5 counts
    i430-Flex 10x 0.5 A to 600 A 0.1 A ±0.5% ±5 counts
    1mV/A 1x 5 A to 2000 A 1A ±0.5% ±5 counts
    1mV/A 10x 0.5 A A to 200 A (AC only) 0.1 A ±0.5% ±5 counts
    Apk i430-Flex 8400 Apk 1 Arms ±5%
    1mV/A 5500 Apk 1 Arms ±5%
    A Crest Factor (CF) 1 to 10 0.01 ±5%
    Amps½ i430-Flex 1x 5 A to 6000 A 1 A ±1% ±10 counts
    i430-Flex 10x 0.5 A to 600 A 0.1 A ±1% ±10 counts
    1mV/A 1x 5 A to 2000 A 1 A ±1% ±10 counts
    1mV/A 10x 0.5 A A to 200 A (AC only) 0.1 A ±1% ±10 counts
    Afund i430-Flex 1x 5 A to 6000 A 1 A ±0.5% ±5 counts
    i430-Flex 10x 0.5 A to 600 A 0.1 A ±0.5% ±5 counts
    1mV/A 1x 5 A to 2000 A 1 A ±0.5% ±5 counts
    1mV/A 10x 0.5 A A to 200 A (AC only) 0.1 A ±0.5% ±5 counts
    Hz
    Fluke 434 @ 50 Hz Nominal 42.50 Hz to 57.50 Hz 0.01 Hz ±0.01 Hz
    Fluke 434 @ 60 Hz Nominal 51.00 Hz to 69.00 Hz 0.01 Hz ±0.01 Hz
    Power
    Watts (VA, var) i430-Flex max 6000 MW 0.1 W to 1 MW ±1% ±10 counts
    1 mV/A max 2000 MW 0.1 W to 1 MW ±1% ±10 counts
    Power Factor (Cos j/DPF) 0 to 1 0.001 ±0.1% @ nominal load conditions
    Energy
    kWh (kVAh, kvarh) i430-Flex 10x Depends on clamp scaling and V nominal ±1% ±10 counts
    Energy Loss i430-Flex 10x Depends on clamp scaling and V nominal ±1% ±10 counts Excluding line resistance accuracy
    Harmonics
    Harmonic Order (n) DC, 1 to 50 Grouping: Harmonic groups according to IEC 61000-4-7
    Inter-Harmonic Order (n) OFF, 1 to 50 Grouping: Harmonic and Interharmonic subgroups according to IEC 61000-4-7
    Volts % f 0.0% to 100% 0.1% ±0.1% ±n x 0.1%
    r 0.0% to 100% 0.1% ±0.1% ±n x 0.4%
    Absolute 0.0 to 1000 V 0.1 V ±5% 1
    THD 0.0% to 100% 0.1% ±2.5%
    Amps % f 0.0% to 100% 0.1% ±0.1% ±n x 0.1%
    r 0.0% to 100% 0.1% ±0.1% ±n x 0.4%
    Absolute 0.0 to 600 A 0.1 A ±5% ±5 counts
    THD 0.0% to 100% 0.1% ±2.5%
    Watts % f or r 0.0% to 100% 0.1% ±n x 2%
    Absolute Depends on clamp scaling and V nominal ±5% ±n x 2% ±10 counts
    THD 0.0% to 100% 0.1% ±5%
    Phase Angle -360° to +0° ±n x 1°
    Flicker
    Plt, Pst, Pst (1 min) Pinst 0.00 to 20.00 0.01 ±5%
    Unbalance
    Volts % 0.0% to 20.0% 0.1% ±0.1%
    Amps % 0.0% to 20.0% 0.1% ±1%
    Mains Signaling
    Threshold Levels Threshold, limits and signaling duration is programable for two signaling frequencies
    Signaling Frequency 60 Hz to 3000 Hz 0.1 Hz
    Relative V % 0% to 100% 0.10% ±0.4%
    Absolute V3s (3 second avg.) 0.0 V to 1000 V 0.1 V ±5% of nominal voltage
    General Specifications
    Case Design Rugged, shock proof with integrated protective holster Drip and dust proof IP51 according to IEC60529 when used in tilt stand position Shock and vibration Shock 30 g, vibration: 3 g sinusoid, random 0.03 g 2 /Hz according to MIL-PRF-28800F Class 2
    Display Brightness: 200 cd/m 2 typ. using power adapter, 90 cd/m 2 typical using battery power Size: 127 x 88 mm (153 mm/6.0 in diagonal) LCD Resolution: 320 x 240 pixels Contrast and brightness: user-adjustable, temperature compensated
    Memory 16GB Wi-Fi SD card for standard models or 8GB SD card for /INTL models (SDHC compliant, FAT32 formatted), up to 32GB optionally. Screen save and multiple data memories for storing data including recordings (dependent on memory size).
    Real-Time Clock Time and date stamp for Trend mode, Transient display, System Monitor and event capture
    Environmental
    Operating Temperature 0°C ~ +40°C; +40°C ~ +50°C excl. battery
    Storage Temperature -20°C ~ +60°C
    Humidity +10°C ~ +30°C: 95% RH non-condensing
    +30°C ~ +40°C: 75% RH non-condensing
    +40°C ~ +50°C: 45% RH non-condensing
    Maximum Operating Altitude Up to 2,000 m (6666 ft) for CAT IV 600 V, CAT III 1000 V
    Up to 3,000 m (10,000 ft) for CAT III 600 V, CAT II 1000 V
    Maximum storage altitude 12 km (40,000 ft)
    Electro-Magnetic-Compatibility (EMC) EN 61326 (2005-12) for emission and immunity
    Interfaces Mini-USB-B, Isolated USB port for PC connectivity SD card slot accessible behind instrument battery
    Warranty Three years (parts and labor) on main instrument, one year on accessories
    • Test lead set
    • i430 Thin flexible current probes (4)
    • Battery
    • Power adapter
    • 8GB SD card
    • Soft carry case
    • CD Rom with PowerLog 430-II software and user documentation