• Store Locator
  • Schedule a
    Demo
  • Add products to your Toolbox to save it for requesting a quote while you keep browsing for other products to complete your list.

    My
    Toolbox
  • FLUKE 115 True RMS Field Service Technicians Multimeter – 600VAC/DC

    # 115

    • True RMS; 600V AC/DC; Ohms; Continuity. Measures 20A; 30 seconds momentary; 10A continuous.
    • Measure voltage; continuity; resistance; diode and capacitance
    • Simple and effective tool for general electrical and electronic testing

    The Fluke 115 is the compact, general purpose troubleshooting tool for field service technicians

     

    For general purpose electrical and electronic test requirements, the Fluke 115 True RMS digital multimeter provides the perfect answer. Its simple, one-handed operation and compact design meets the needs of a wide variety of field service technicians. It measures True RMS voltage and current with 6000 count resolution as well as resistance, continuity, frequency and capacitance for quick verifications.

    Fluke 115 Digital Multimeters are independently tested for safe use in CAT III 600V environments.

     

    • General purpose digital multimeter for electrical and electronic testing
    • Ideal for quick verifications and field service
    • Presents a large white LED backlight for working in poorly lit areas
    • Measures AC and DC voltage to 600V
    • Measures AC and DC current to 10A (20 A overload for 30-seconds max)

     

    Other useful features:

    • Measures resistance, continuity, frequency, and capacitance
    • Provides Min/Max/Average with elapsed time to record signal fluctuations
    • Comes with a holster with probe holders for easy storage
    • Features a compact ergonomic design for one-handed operation
    • Fits into optional ToolPak™ magnetic hanger for hands-free operation
    • CAT III 600 V safety rated

    2019 Best Multimeters, Top Pick – GeekWrapped.com

    Specifications
    Maximum voltage between any terminal and earth ground600 V
    Surge protection6 kV peak per IEC 61010–1 600 VCAT III, Pollution Degree 2
    DisplayDigital: 6,000 counts, updates 4 per second
    Bar graph33 segments, updates 32 per second
    Operating temperature-10°C to + 50°C
    Storage temperature-40°C to + 60°C
    Battery type9 volt Alkaline, NEDA 1604A/ IEC 6LR61
    Battery life400 hours typical, without backlight
    Accuracy Specifications
    DC millivoltsRange/resolution600.0 mV / 0.1 mV
    Accuracy± ([% of reading] + [counts]): 0.5% + 2
    DC voltsRange/resolution6.000 V / 0.001 V
    60.00 V / 0.01 V
    600.00 V / 0.1 V
    Accuracy± ([% of reading] + [counts]): 0.5% + 2
    AC millivolts1 True RMSRange/resolution600.0 mV / 0.1 mV
    Accuracy1.0% + 3 (DC, 45 Hz to 500 Hz)
    2.0% + 3 (500 Hz to 1 kHz)
    AC volts1 True RMSRange/resolution6.000 V / 0.001 V
    60.00 V / 0.01 V
    600.0 V / 0.1 V
    Accuracy1.0% + 3 (DC, 45 Hz to 500 Hz)
    2.0% + 3 (500 Hz to 1 kHz)
    ContinuityRange/resolution600 Ω / 1 Ω
    AccuracyBeeper on < 20 Ω, off > 250 Ω detects opens or shorts of
    500 μs or longer.
    OhmsRange/resolution600.0 Ω / 0.1 Ω
    6.000 kΩ / 0.001 kΩ
    60.00 kΩ / 0.01 kΩ
    600.0 kΩ / 0.1 kΩ
    6.000 MΩ / 0.001 MΩ
    Accuracy0.9% + 1
    Range/resolution40.00 MΩ / 0.01 MΩ
    Accuracy5% + 2
    Diode testRange/resolution2.00 V / 0.001 V
    Accuracy0.9% + 2
    CapacitanceRange/resolution1000 nF / 1 nF
    10.00 μF / 0.01 μF
    100.0 μF / 0.1 μF
    9999 μF / 1 μF
    100 μF to 1000 μF
    Accuracy1.9% + 2
    Range/resolution> 1000 μF
    Accuracy5% + 20%
    Lo-Z capacitanceRange1 nF to 500 μF
    Accuracy10% + 2 typical
    AC amps True RMSRange/resolution6.000 A / 0.001 A
    (45 Hz to 500Hz)10.00 A / 0.01 A
    Accuracy1.5% + 3
    20 A overload for 30-seconds max
    DC ampsRange/resolution6.000 A / 0.001 A
    10.00 A / 0.01 A
    Accuracy1.0% + 3
    20 A overload for 30-seconds max
    Hz (V or A input)2Range/resolution99.99 Hz / 0.01 Hz
    999.9 Hz / 0.01 Hz
    9.999 kHz / 0.001 kHz
    50 kHz / 0.01 kHz
    Accuracy0.1% + 2
    1. All AC voltage ranges except Auto-V/LoZ are specified from 1% to 100% of range. Auto-V/LoZ is specified from 0.0 V.
    2. Frequency is AC coupled, 5Hz to 30 kHz for AC voltage.
    2. Temperature uncertainty (accuracy) does not include the error of the thermocouple probe.
    2. Frequency is AC coupled, 5 Hz to 50 kHz for AC voltage. Frequency is DC coupled, 45 Hz to 5 kHz for AC current.
    2. Temperature Range/Resolution: -40°F to 752°F / 0.2°F.
    Mechanical & General Specifications
    Size167 x 84 x 46 mm (6.57 x 3.31 x 1.82 in)
    Weight550 g
    Warranty3 years
    • Holster
    • Installed 9 V battery
    • 4 mm silicone test lead sets
    • User manual

    Provide us your contact detailsone of our product experts will contact you to discuss your needs or schedule a demonstration at a time that suits

    Product selected: Model #







      *Demonstrations can only be scheduled within the UAE

      Sign up to stay in the know-how of our latest products, updates, special offers, and more.

      • Subscription Form