• Store Locator
  • Schedule a
    Demo
  • Add products to your Toolbox to save it for requesting a quote while you keep browsing for other products to complete your list.

    My
    Toolbox
  • Create a Requisition

    FLUKE 110 True RMS Digital Multimeter

    # 110

    • True-rms ac voltage for accurate measurements on non-linear signals
    • Resistance and continuity
    • Large white LED backlight to work in poorly lit areas
    FLUKE
    • FLUKE
    • 110
    • True-rms ac voltage for accurate measurements on non-linear signals
    • Large white LED backlight to work in poorly lit areas
    • Resistance and continuity
    • Min/Max/Average to record signal fluctuations
    • CAT III 600 V safety rated
    General specifications
    Maximum voltage (between any terminal and earth ground) 600V
    Safety IEC 61010-1, Pollution degree 2
    IEC 61010-2-033, CAT III 600 V
    Display Digital: 6,000 counts, updates 4/sec
    Bar graph 33 segments, updates 32/sec
    Temperature
    Operating
    Storage
     
    -10 °C to + 50 °C
    -40 °C to + 60 °C
    Battery 9 volt Alkaline, IEC 6LR61
    Battery life 400 hours typical, without backlight
    Accuracy
    Measurement Range Resolution Accuracy ± ([% of reading] + [counts])
    DC millivolts 600.0 mV 0.1 mV 0.5 % + 2
    DC volts 6.000 V
    60.00 V
    600.0 V
    0.001 V
    0.01 V
    0.1 V
    0.5 % + 2
    Accuracy
    Measurement Range Resolution Accuracy ± ([% of reading] + [counts])
    AC millivolts1 true-rms 600.0 mV 0.1 mV 1.0 % + 3 (dc, 45 Hz to 500 Hz)
    2.0 % + 3 (500 Hz to 1 kHz)
    AC volts1 true-rms 6.000 V
    60.00 V
    600.0 V
    0.001 V
    0.01 V
    0.1 V
    1.0 % + 3 (dc, 45 Hz to 500 Hz) 2.0 % + 3 (500 Hz to 1 kHz)
    Continuity 600 Ω 1 Ω Beeper on < 20 Ω, off> 250 Ω; detects opens or shorts of 500 μs or longer.
    Ohms 600.0 Ω 0.1 Ω 0.9 % + 2
    6.000 kΩ
    60.00 kΩ
    600.0 kΩ
    6.000 MΩ
    0.001 kΩ
    0.01 kΩ
    0.1 kΩ
    0.001 MΩ
    0.9 % + 1
    40.00 MΩ 0.01 MΩ 5 % + 2

    1All ac voltage ranges are specified from 1 % to 100% of range. Because inputs below 1 % of range are not specified, it is normal for this and other true-rms meters to display non-zero readings when the test leads are disconnected from a circuit or are shorted together. For volts, crest factor of ≤ 3 at 4000 counts, decreasing linearly to 1.5 at full scale. AC volts is ac-coupled.