• Store Locator
  • Schedule a
    Demo
  • Add products to your Toolbox to save it for requesting a quote while you keep browsing for other products to complete your list.

    My
    Toolbox
  • FLUKE 1748-15-INTL Power Quality Logger w/60 cm 1,500A iFlex, INTL

    # 1748-15-INTL

    • Measure all three voltage and current phases plus the neutral current
    • Comprehensive logging
    • Measure with premium accuracy

    Software Features

    • “In-workshop” or “in-the-field” setup and download through PC application software: simple download using USB memory stick, WiFi download, wired ethernet connection or via USB cable.
    • Energy Analyze plus application software: Download and analyze every measured detail of energy consumption and power quality state-of-health with automated reporting.
    • One-touch reporting: Create standardized reports according to commonly used standards like EN 50160, IEEE 519, GOST 33073 or export data in PQDIF or NeQual compatible format for use with third party software.
    • Advanced analysis: Choose any available logged parameter to create a highly customized view of logged measurements for advanced correlation of data.

     

    Hardware Features

    • Measure all three voltage and current phases plus the neutral current: Three-phase and neutral voltage leads and four flexible current probes.
    • Comprehensive logging: More than 20 separate logging sessions can be stored in the instrument. A comprehensive range of power and power quality variables are automatically logged so you never lose measurement trends.
    • Measure with premium accuracy: Meets the rigorous IEC 61000-4-30 Class A Edition 3 standard for ‘Testing and measurement techniques–Power quality measurement methods.’
    • Capture dips, swells and interruptions: The 1748 includes event waveform capture and RMS event profile, along with date, timestamp and severity information to help pinpoint potential root causes of power quality issues.
    • Measure key power quality parameters: Measures harmonics and interharmonics for voltage and current, also includes unbalance, flicker and rapid voltage changes.
    • Optimized user interface: Capture the right data every time with quick, guided, graphical PC based application setup and reduce uncertainty about your connections with an intelligent verification feature and the only auto-correction function for a power quality logger. Connection errors are automatically indicated via an amber light on the units power button which turns green once corrected.
    • Optimized user interface: Quick, guided, graphical setup ensures you’re capturing the right data every time, and the intelligent verification function indicates correct connections have been made, reducing user uncertainty
    • Flexible power supply: Powers directly from the measured circuit with the widest available range for a power quality logger automatically going from 100 V to 500 V or from a wall line cord, so you can test anywhere.
    • Rugged and reliable: Designed to withstand harsh installation environments with IP65 rating when used with IP65 voltage input adapter.
    • Two external USB ports: One for PC connection and another for quick, simple data download to standard USB thumb drives, or other USB devices, allowing you to leave the measurement device in place without disrupting logging.
    • Ethernet connectivity: Wired and wireless connections for instrument setup and high-speed data download.
    • Compact size: Designed to fit in tight spaces and panels with small 23 cm x 18 cm x 5.4 cm (9.1 in x 7.1 in x 2.1 in) footprint.
    • Highest safety rating in the industry: 600 V CAT IV/1000 V CAT III rated for use at the service entrance and downstream.
    • Optimized measurement accessories: Unique tangle-free flat voltage cable and thin flexible current probes ensure easy installation even in tight spaces.
    • Battery life: Four-hour operating time (backup time) per charge on lithium-ion battery to withstand temporary power disruptions.
    • Security: Safeguard your best asset from theft with a standard chain or other security device.
    • Magnetic hanger kit: Conveniently stow the instrument safely inside or outside of electrical panels; compatible with all models and included with 1748 model as standard.

     

    Which power quality logger is right for you?

    Features174217461748
    Functions
    Voltage, current, power, power factor, frequency
    Energy forward/reverse
    Peak Demand
    THD
    Flicker
    Voltage and current harmonics (to 50th)1
    Unbalance1
    Rapid voltage change events1
    Interharmonics (to 50th)1
    Dips, swells, interruption and transient events tables1
    Inrush current1
    Transients (low frequency) / Waveform deviation events2
    Recording
    Trend
    Waveform snapshots2
    RMS profile2
    Communication
    Ethernet
    USB (mini B)
    WiFi download Instrument to device
    Wifi download via WiFi hub (requires registration)Opt.Opt.Opt.
    Included accessories
    Flexible current probenot /B versionnot /B versionnot /B version
    USB stick
    USB cable
    3PHVL-1730 3-Phase + neutral voltage test lead
    Test lead set red/black 0.18 m
    Test lead set red/black 1.5 m
    Alligator clips444
    173x/174x Soft Case
    Cable marker kit
    MP1-3R/1B-Magnet Probe 1 set (3 red, 1 black)Opt.11
    174x-Hanger KitOpt.Opt.
    Specifications
    Accuracy
    ParameterRangeMaximum ResolutionIntrinsic Accuracy at Reference Conditions (% of Reading +% of Range)
    Voltage1000 V0.1 V±0.1 % of nominal voltage 1, 2
    Current: Direct inputi17xx-flex 1500IP 24 1500 A150 A0.01 A (min. 1.5A)3±(1% + 0.02%)
    1500 A0.1 A
    i17xx-flex 3000IP 24 3000 A300 A0.01 A (min. 3.0 A)3±(1% + 0.03%)
    3000 A0.1 A
    i17xx-flex 6000IP 36 6000 A600 A0.01 A (min. 6.0 A)3±(1.5% + 0.03%)
    6000 A0.1 A
    i40s-EL clamp4 A1 mA±(0.7% + 0.02%)
    40 A10 mA
    Frequency42.5 Hz to 69 Hz0.01 Hz±(0.1%)2
    Auxiliary input±10 V dc0.1 mV±(0.2% + 0.02%)
    Voltage min/max1000 V0.1 V±0.2 % of nominal input voltage1
    Current min/maxDefined by accessoryDefined by accessory±(5% + 0.2%)
    THD on voltage1000%0.10%± 2.5%
    THD on current1000%0.10%± 2.5%
    Voltage harmonics 2nd to 50th1000 V0.1 V≥ 1 V: ±5% of reading
    < 1 V: ±0.05V
    Current harmonics 2nd to 50thDefined by accessoryDefined by accessory≥ 3% of current range: ±5% of reading
    < 3% of current range: ±0.15% of range
    Flicker PLT, PST0 to 200.015%
    Current probe accuracy
    ParameterInfluence quantity/ iFlex1500IP-24iFlex3000IP-24 iFlex6000IP-36i40S-EL
    150 A / 1500 A300 A / 3000 A600 A / 6000 A4 A / 40 A
    Active Power PPF ≥ 0.991.2% + 0.005%1.2% + 0.0075%1.7% + 0.0075%1.2% + 0.005%
    Active Energy Ea
    Apparent power S0 ≤ PF ≤ 11.2% + 0.005%1.2% + 0.0075%1.7% + 0.0075%1.2% + 0.005%
    Apparent Energy Eap
    Reactive power Q0 ≤ PF ≤ 12.5% of measured apparent power
    Reactive Energy Er
    Power Factor PF±0.025
    Displacement Power
    Factor DPF/cosΦ
    Additional uncertainty in% of rangeVP-N>250 V0.015%0.023%0.023%0.015%
    1 In the range of 100 V … 500 V; also known as Udin
    2 0 °C … 45 °C: Intrinsic accuracy x 2, outside of 0 °C … 45 °C: Intrinsic accuracy x 3
    3 Consult operators manual for details
    Reference conditions:

    Environmental: 23 °C ± 5 °C, instrument operating for at least 30 minutes, no external electrical/magnetic field, RH <65 %
    Input conditions: Cosφ/PF=1, Sinusoidal signal f=50 Hz/60 Hz, power supply 120 V/230 V ±10 %.
    Current and power specifications: Input voltage 1 ph: 120 V/230 V or 3 ph wye/delta: 230 V/400 V
    Input current: I > 10 % of I range
    Primary conductor of clamps or Rogowski coil in center position
    Temperature coefficient: Add 0.1 x specified accuracy for each degree C above 28 °C or below 18 °C
    Electrical Specifications
    Power Supply
    Voltage range100 V to 500 V using safety plug input when powering from the measurement circuit
    100 V to 240 V MA-C8 and using standard power cord (IEC 60320 C7)
    Power consumptionMaximum 50 VA (max. 15 VA when powered using MA-C8 adapter)
    Efficiency≥ 68.2% (in accordance with energy efficiency regulations)
    Maximum no-load consumption< 0.3 W only when powered using IEC 60320 input
    Mains power frequency50/60 Hz ±15%
    BatteryLi-ion 3.7 V, 9.25 Wh, customer-replaceable
    On-battery runtimeTypically 4 hours
    Charging time< 6 hours
    Data Acquisition
    Resolution16-bit synchronous sampling
    Sampling frequency10.24 kHz at 50/60 Hz, synchronized to mains frequency
    Input signal frequency50/60 Hz (42.5 to 69 Hz)
    Circuit types1-Φ, 1-Φ IT, split phase, 3-Φ delta, 3-Φ wye, 3-Φwye IT, 3-Φ wye balanced, 3-Φ Aron/Blondel (2-element delta), 3-Φ delta open leg, currents only (load studies)
    Data storageInternal flash memory (not user replaceable)
    Memory sizeTypical 20 logging sessions of 4 weeks with 1-minute intervals and 500 events
    Basic Interval
    Measured parametersVoltage, current, aux, frequency, THD V, THD A, power, power factor, fundamental power, DPF, energy
    Averaging intervalUser selectable: 1 sec, 5 sec, 10 sec, 30 sec, 1 min, 5 min, 10 min, 15 min, 30 min
    Averaging time min/max valuesVoltage, Current: Full cycle RMS updated every half cycle (URMS1/2 according to IEC61000-4-30 Aux, Power: 200ms)
    Demand Interval (Energy Meter Mode)
    Measured parametersEnergy (Wh, varh, VAh), PF, maximum demand, cost of energy
    IntervalUser selectable: 5 min, 10 min, 15 min, 20 min, 30 min, off
    Power Quality Measurements
    Measured parameterVoltage, frequency, unbalance, voltage harmonics, THD V, current, harmonics, THD A, TDD, voltage interharmonics, TID V, current interharmonics, TID A, Flicker, Mains Signaling, under/over deviation
    Averaging interval10 min for all parameters
    2 hrs (long term Flicker PLT)
    150/180 cycles (3 s) for harmonics (requires software license IEEE519/REPORT)
    Individual harmonics2nd to 50th harmonic
    Grouping according to IEC 61000-4-7 user configurable depending on application: Sub-grouped (harmonics + interharmonics), grouped or harmonic bins only
    Interharmonics1st to the 50th interharmonic
    Total harmonic distortionCalculated on 50 voltage harmonics
    EventsVoltage: dips, swells, interruptions, current: inrush current
    1748: mains signaling, transients (low frequency)
    Triggered recordingsRMS profile: Full cycle RMS updated every half cycle of voltage and current up to 11 s (URMS1/2 according to IEC 61000-4-30)
    Waveform of voltage and current up to 200 ms, 10/12 cycles
    Mains signaling: 10/12 cycle RMS recording of the configured frequencies up to 120s
    InrushRMS profile based on 1/2 cycle RMS steady state triggering
    FlickerIn accordance with IEC 61000-4-15 and IEEE 1453
    Mains signalingTwo user defined frequencies up to 3 kHz
    PQ HealthSummarizes power quality measurements in one table. Detailed data available for each parameter
    EN 50160Compliance with standard
    Programmable PQ limitsEnables user defined limits for local standards compliance
    Standards Compliance
    HarmonicsIEC 61000-4-7: Class 1
    IEEE 519 (short time and very short time harmonics)
    Power qualityIEC 61000-4-30 Class A, IEC 62586-1, IEC 62586-2 (PQI-A-PI device)
    PowerIEEE 1459
    Power quality complianceEN 50160
    SafetyGeneral: IEC 61010-1: Pollution Degree 2
    Measurement: IEC 61010-2-033: CAT IV 600 V / CAT III 1000 V
    Power Supply: Overvoltage Category IV, Pollution Degree 2
    Li-ion Battery: IEC 62133
    Interfaces
    USB-AFile transfer via USB flash drive, firmware updates, max. supply current: 120 mA
    WiFiFile transfer and remote control via direct connection or WiFi infrastructure
    BluetoothRead auxiliary measurement data from Fluke Connect® 3000 series modules (requires supported USB to BLE or WiFi/BLE adapter, check for availability)
    USB-miniData download device to PC
    Voltage Inputs
    Number of inputs4 (3 phases referenced to neutral)
    Maximum input voltage1000 Vrms, CF 1.7
    Input impedance10 MΩ
    Bandwidth42.5 Hz to 3.5 kHz
    Scaling1:1 and variable
    Measurement category1000 V CAT III/600 V CAT IV
    Current Inputs
    Number of inputs4 (3 phases and neutral), mode selected automatically for attached sensor
    Input voltageClamp input: 500 mVrms/50 mVrms; CF 2.8
    Rogowski coil input: 150 mVrms/15 mVrms at 50 Hz, 180 mVrms/18 mVrms at 60 Hz; CF 4 all at nominal probe range
    Range1 A to 150 A/10 A to 1500 A with thin flexible current probe i17XX-flex1500 IP 24
    3 A to 300 A/30 A to 3000 A with thin flexible current probe i17XX-flex3000 IP 24
    6 A to 600 A/60 A to 6000 A with thin flexible current probe i17XX-flex6000 IP 36
    40 mA to 4 A/0.4 A to 40 A with 40 A clamp i40s-EL
    Bandwidth42.5 Hz – 3.5 kHz
    Scaling1:1 and variable
    Auxiliary Inputs
    Number of inputs2 (Analog with auxiliary adapter, or up to 2 BLE devices simultaneously)
    Input range0 to ± 10 V dc, or 0 to ± 1000 V dc (with optional adapter), 1 reading/s
    Scale factorFormat: mx + b (gain and offset) user configurable
    Displayed unitsUser configurable (7 characters, for example, °C, psi, or m/s)
    Wireless Bluetooth connection (check for availability)
    Number of inputs2
    Supported modulesFluke Connect® 3000 series
    Acquisition1 reading/s
    Environmental Specifications
    Operating temperature-25 °C to +50 °C (-13 °F to 122 °F)1
    Storage temperatureWithout battery: -25 °C to +60 °C (-13 °F to 140 °F), with battery: -20 °C to +50 °C (−4 °F to 122 °F)
    Operating humidityIEC 60721-3-3: 3K6:
    -25 °C to +30 °C (-13 °F to +86 °F): ≤ 100 %
    40 °C (104 °F): 55 %
    50 °C (122 °F): 35 %
    Operating altitude2000 m (up to 4000 m derate to 1000 V CAT II/600 V CAT III/300 V CAT IV)
    Storage altitude12,000 m
    EnclosureIEC 60529: IP50
    IEC 60529: IP65 with IP65 rated voltage connector
    VibrationIEC 60721-3-3 / 3M2
    Electromagnetic compatibility (EMC)EN 61326-1: Industrial CISPR 11: Group 1, Class A
    IEC 61000-6-5 Power station environment
    Korea (KCC): Class A Equipment (industrial broadcasting and communication equipment)
    USA (FCC): 47 CFR 15 subpart B. This product is considered an exempt device per clause 15.103
    General Specifications
    WarrantyTwo-years (battery not included)
    Accessories: one-year
    Calibration cycle: two-years
    Dimensions23.0 cm x 18.0 cm x 5.4 cm (9.1 in x 7.1 in x 2.1 in)
    WeightInstrument: 1 kg (2.2 lb)
    Tamper protectionAccept securing cables (max. Φ 6mm)
    1Warm up the product to -10 °C (+14 °F) before you power the unit on
    i17XX-FLEX1.5KIP Flexible Current Probe Specifications
    Measuring range1 to 150 A ac/10 to 1500 A ac
    Probe cable length610 mm (24 in)
    Probe cable diameter7.5 mm (0.3 in)
    Weight170 g (0.38 lb)
    Minimum bending radius38 mm (1.5 in)
    Nondestructive current100 kA (50/60 Hz)
    Temperature coefficient over
    operating temperature range
    0.05 % of reading/°C (0.028 % of reading/°F)
    Working voltage1000 V CAT III, 600 V CAT IV
    Output cable length2.0 m (6.5 ft)
    Probe cable materialTPR
    Weight115 g
    Probe cable materialTPR
    Coupling materialPOM + ABS/PC
    Output cableTPR/PVC
    Operating temperature-20 °C to +70 °C (-4 °F to 158 °F) temperature of conductor under test shall not exceed 80 °C (176 °F)
    Temperature, non-operating-40 °C to +80 °C (-40 °F to 176 °F)
    Relative humidity, operating15% to 85% non-condensing
    IP ratingIEC 60529: IP65
    WarrantyOne-year
    • Power quality logger with 24in/60cm 1,500A iFlex current probes, EU/US version

    Provide us your contact detailsone of our product experts will contact you to discuss your needs or schedule a demonstration at a time that suits

    Product selected: Model #







      *Demonstrations can only be scheduled within the UAE

      Sign up to stay in the know-how of our latest products, updates, special offers, and more.

      • Subscription Form