    FLUKE 1507 Insulation Resistance Testers

    # 1507

    • Automatically calculates Polarization Index and Dielectric Absorption Ratio
    • Makes repetitive tests simple and easy with a Compare (Pass/Fail) function
    • Offers multiple insulation test voltages: 50 V, 100 V, 250 V, 500 V, and 1000 V
    FLUKE
    • FLUKE
    • 1507
    • Type

    Quantity:

    - +
      ADD TO MY TOOLBOX
    Where to buy this product?

    The Fluke 1507 is a versatile, compact, handheld insulation tester for advanced industrial and electrical insulation testing. Its multiple test voltages make it the ideal tool for many troubleshooting, commissioning, and preventative maintenance applications.

    • Performs insulation tests from 0.01 MΩ to 2.0 GΩ
    • Includes live circuit detection to prevent insulation test if voltage >30 V is detected
    • Includes auto-discharge of capacitive voltage for added user protection
    • Measures AC/DC voltage from 0.1 V to 600 V and resistance from 0.01 Ω to 20.00 kΩ
    • Provides lo-ohms earth-bond continuity (200 mA)
    • Simplifies repetitive or hard-to-reach testing with the remote test probe
    • Saves battery power with auto power off
    • Presents results on a large, backlit display
    • Features CAT IV 600 V overvoltage category rating
    • Comes with remote probe, test leads, test probes, alligator clips and one-year warranty
    • Accepts optional Fluke TPAK magnetic hanging system to free your hands for other work
    • Runs on four AA alkaline batteries (NEDA 15 A or IEC LR6) for at least 1000 insulation tests
    AC/DC Voltage Measurement
    Accuracy Range 600.0 V
    Resolution 0.1 V
    50 Hz to 400 Hz ± (% of Rdg + Digits) ±(2% + 3)
    Input impedance 3 MΩ (nominal), < 100 pF
    Common mode rejection ratio (1 kΩ unbalanced): > 60 dB at DC, 50 or 60 Hz
    Overload protection 600 V rms or DC
    Earth Bond Resistance Measurement
    Range/Resolution 20.00 Ω 0.01 Ω
    200.0 Ω 0.1 Ω
    2000 Ω 1.0 Ω
    20.00 kΩ 0.01 kΩ
    Accuracy ±(1.5% + 3)
    Overload protection 2 V rms or DC
    Open circuit test voltage > 4.0 V, < 8 V
    Short circuit current > 200.0 mA
    Insulation Specifications
    Measurement range 0.01 MΩ to 10 GΩ
    Test voltage 50 V, 100 V, 250 V, 500 V, 1000 V
    Test voltage accuracy + 20%, – 0%
    Short circuit current 1 mA nominal
    Auto discharge Discharge time < 0.5 second for C = 1 µF or less
    Live circuit indicator Inhibit test if terminal voltage > 30 V prior to initialization of test
    Maximum capacitive load Operable with up to 1 µF load
    Measure accuracy 50 V ±(3% + 5)
    100 V ±(3% + 5)
    250 V ±(1.5% + 5)
    500 V ±(1.5% + 5)
    1000 V ±(1.5% + 5) to 2000 MΩ, ±(10% + 3) above 2000 MΩ
    General Specifications
    Maximum voltage applied to any terminal: 600 V AC rms or DC
    Storage temperature -40°C to 60°C (-40°F to 140°F)
    Operating temperature -20°C to 55°C (-4°F to 131°F)
    Temperature coefficient 0.05 x (specified accuracy) per °C for temperatures < 18°C or > 28°C (< 64°F or > 82°F)
    Relative humidity
    0% to 95% @ 10°C to 30°C (50°F to 86°F)
    0% to 75% @ 30°C to 40°C (86°F to 104°F)
    0% to 40% @ 40°C to 55°C (104°F to 131°F)
    Vibration Random, 2 g, 5-500 Hz per MIL-PRF-28800F, Class 2 instrument
    Shock 1 meter drop per IEC 61010-1 2nd Edition (1 meter drop test, six sides, oak floor)
    Electromagnetic compatibility In an RF field of 3 V/M, accuracy = specified accuracy (EN 61326-1:1997)
    Safety Complies with ANSI/ISA 82.02.01 (61010-1) 2004, CAN/CSA-C22.2 NO. 61010-1-04, and IEC/EN 61010-1 2nd Edition for measurement category IV 600 V (CAT IV)
    Certifications CSA per standard CSA/CAN C22.2 No. 61010.1-04; TUV per standard IEC/EN 61010-1 2nd Edition
    Batteries Four AA batteries (NEDA 15A or IEC LR6)
    Battery life Insulation test use: Tester can perform at least 1000 insulation tests with fresh alkaline batteries at room temperature. These are standard tests of 1000 V into 1 MΩ with a duty cycle of 5 seconds on and 25 seconds off.
    Resistance measurements: Tester can perform at least 2500 earth bond resistance measurements with fresh alkaline batteries at room temperature. These are standard tests of 1 Ω with a duty cycle of 5 seconds on and 25 seconds off.
    Size (H x W x L) 5.0 x 10.0 x 20.3 cm (1.97 x 3.94 x 8.00 in)
    Weight 550 g (1.2 lb)
    IP rating IP40
    Altitude Operating 2000 m CAT IV 600 V, 3000 m CAT III 600 V
    Non-operating (storage) 12,000 m
    Over-range capability 110% of range
    • TL224 Test Leads
    • TP74 Test Probes
    • Clips PN 1958654 (red) and PN 1958646 (black)
    • Holster
    • Remote probe

    Provide us your contact detailsone of our product experts will contact you to discuss your needs or schedule a demonstration at a time that suits

    Product selected: Model #