• Store Locator
  • Schedule a
    Demo
  • Add products to your Toolbox to save it for requesting a quote while you keep browsing for other products to complete your list.

    My
    Toolbox
  • FLUKE 116 Digital HVAC Multimeter 600V AC/DC

    # 116

    • Built-in thermometer for HVAC applications
    • Microamps to test flame sensors
    • Resistance; continuity; frequency and capacitance

    The Fluke 116 DMM provides the features you need to quickly troubleshoot HVAC equipment

     

    The Fluke 116 was specifically designed for HVAC professionals. It has everything you need to quickly troubleshoot problems with HVAC equipment and flame sensors, including a built-in thermometer to measure temperatures up to 400°C (752°F) and microamps to test flame sensors. The Fluke 116 also measures resistance, continuity, frequency, and capacitance. And the large white LED backlight makes it easy to see results even in poorly lit areas.

    Fluke 116 multimeters are independently tested for safe use in CAT III 600 V environments.

     

    • Digital multimeter designed specifically for HVAC professionals
    • Includes built-in thermometer to measure temperature from -40°C to 400°C (-40°F to 752°F)
    • Provides microamps to test flame sensors
    • Features low input impedance to helps prevent false readings due to ghost voltage
    • Presents a large white LED backlight for working in poorly lit areas

     

     

    Other useful features:

    • Measures resistance, continuity, frequency, and capacitance
    • Provides Min/Max/Average to record signal fluctuations
    • Comes with a holster with probe holders for easy storage
    • Features a compact ergonomic design for one-handed operation
    • Fits into optional ToolPak™ magnetic hanger for hands-free operation
    • CAT III 600 V safety rated
    Specifications
    Maximum voltage between any terminal and earth ground600 V
    Surge protection6 kV peak per IEC 61010–1 600 VCAT III, Pollution Degree 2
    DisplayDigital: 6,000 counts, updates 4 per second
    Bar graph33 segments, updates 32 per second
    Operating temperature-10°C to + 50°C
    Storage temperature-40°C to + 60°C
    Battery type9 volt Alkaline, NEDA 1604A/ IEC 6LR61
    Battery life400 hours typical, without backlight
    Accuracy Specifications
    DC millivoltsRange/resolution600.0 mV / 0.1 mV
    Accuracy±([% of reading] + [counts]): 0.5% + 2
    DC voltsRange/resolution6.000 V / 0.001 V
    60.00 V / 0.01 V
    600.00 V / 0.1 V
    Accuracy±([% of reading] + [counts]): 0.5% + 2
    Auto voltsRange/resolution600.0 V / 0.1 V
    Accuracy2.0% + 3 (DC, 45 Hz to 500 Hz)
    4.0% + 3 (500 Hz to 1 kHz)
    AC millivolts1 True RMSRange/resolution600.0 mV / 0.1 mV
    Accuracy1.0% + 3 (DC, 45 Hz to 500 Hz)
    2.0% + 3 (500 Hz to 1 kHz)
    AC volts1 True RMSRange/resolution6.000 V / 0.001 V
    60.00 V / 0.01 V
    600.0 V / 0.1 V
    Accuracy1.0% + 3 (DC, 45 Hz to 500 Hz)
    2.0% + 3 (500 Hz to 1 kHz)
    ContinuityRange/resolution600 Ω / 1 Ω
    AccuracyBeeper on < 20 Ω, off > 250 Ω detects opens or shorts of
    500 μs or longer.
    OhmsRange/resolution600.0 Ω / 0.1 Ω
    6.000 kΩ / 0.001 kΩ
    60.00 kΩ / 0.01 kΩ
    600.0 kΩ / 0.1 kΩ
    6.000 MΩ / 0.001 MΩ
    Accuracy0.9% + 1
    Range/Resolution40.00 MΩ / 0.01 MΩ
    Accuracy5% + 2
    Diode TestRange/resolution2.00 V / 0.001 V
    Accuracy0.9% + 2
    CapacitanceRange/resolution1000 nF / 1 nF
    10.00 μF / 0.01 μF
    100.0 μF / 0.1 μF
    9999 μF / 1 μF
    100 μF to 1000 μF
    Accuracy1.9% + 2
    Range/resolution> 1000 μF
    Accuracy5% + 20%
    Lo-Z CapacitanceRange1 nF to 500 μF
    Accuracy10% + 2 typical
    Temperature²
    (Type-K thermocouple)
    Range/resolution-40°C to 400°C / 0.1°C
    Accuracy1% + 10²
    Range/resolution-40°F to 752°F / 0.2°F
    Accuracy1% + 18²
    AC μA true-rms (45 Hz to 500 Hz)Range/resolution600.0 μA / 0.1 μA
    Accuracy1.5% + 3
    DC μampsRange/resolution600.0 μA / 0.1 μA
    Accuracy1.0% + 2
    Hz (V or A input)²Range/resolution99.99 Hz / 0.01 Hz
    999.99 Hz / 0.1 Hz
    9.999 Hz / 0.001 Hz
    50.00 Hz / 0.01 Hz
    Accuracy0.1% + 2
    1. All AC voltage ranges except Auto-V/LoZ are specified from 1% to 100% of range. Auto-V/LoZ is specified from 0.0 V.
    2. Temperature uncertainty (accuracy) does not include the error of the thermocouple probe.
    3. Frequency is AC coupled, 5 Hz to 50 kHz for AC voltage. Frequency is DC coupled, 45 Hz to 5 kHz for AC current.
    4. Temperature Range/Resolution: -40°F to 752°F / 0.2°F.
    Mechanical and General Specifications
    Size167 x 84 x 46 mm (6.57 x 3.31 x 1.82 in)
    Weight550 g
    Warranty3 years
    • 4 mm silicone test lead set
    • 80BK Integrated Temperature probe
    • Holster
    • Installed 9 V battery
    • User manual

    Provide us your contact detailsone of our product experts will contact you to discuss your needs or schedule a demonstration at a time that suits

    Product selected: Model #







      *Demonstrations can only be scheduled within the UAE

      Sign up to stay in the know-how of our latest products, updates, special offers, and more.