• Store Locator
  • Schedule a
    Demo
  • Add products to your Toolbox to save it for requesting a quote while you keep browsing for other products to complete your list.

    My
    Toolbox
  • Create a Requisition

    FLUKE BT510 Battery Analyzer, 600V DC with BTL10 Basic Test Lead Set

    # BT510

    • Battery Voltage – During the internal resistance test; Fluke Battery Analyzers also measure the voltage of the battery under test
    • Discharge Volts – The Discharge mode collects the voltage of each battery multiple times at a user defined interval during a discharge or load test.
    • Battery Voltage – During the internal resistance test; Fluke Battery Analyzers also measure the voltage of the battery under test
    • Discharge Volts – The Discharge mode collects the voltage of each battery multiple times at a user defined interval during a discharge or load test. Users can calculate the time a battery takes to drop to the cut-off voltage and use this time to determine the capacity loss of the battery
    • Ripple Voltage Test – Measures unwanted residual ac component of the rectified voltage in dc charging and inverter circuits. Allows users to test ac components in dc charging circuits and find one of the root causes of battery deterioration
    • Meter and Sequence Modes – The Meter mode is used for a quick test or troubleshooting. In this mode you can save and read the readings in a measurement or time sequence. The Sequence mode is for maintenance tasks with multiple power systems and battery strings. Before a task starts; users can configure a profile for the task for data management and report generation
    • Threshold and Warning – Users can configure a maximum of 10 sets of thresholds and receive a Pass/ Warning/ Fail indication after each measurement
    • Intercell Strap Resistance Test and Data Management – Measures the resistance of the intercell connection between batteries in a string.
    • AutoHold – When AutoHold is turned on, a reading is captured when it remains stable for 1 second. The reading is then released when a new measurement starts
    • AutoSave – When AutoSave is turned on, measured values are saved to internal memory automatically after an AutoHold reading is captured
    • Comprehensive logging – All measured values are automatically captured during testing and can be reviewed on the instrument before downloading for on the-go analysis
    FunctionsRangeResolutionAccuracyBT510BT520BT521
    Battery resistance13 mΩ0.001 mΩ1 % + 8
    30 mΩ0.01 mΩ0.8 % + 6
    300 mΩ0.1 mΩ0.8 % + 6
    3000 mΩ1 mΩ0.8 % + 6
    Vdc6 V0.001 V0.09 % + 5
    60 V0.01 V0.09 % + 5
    600 V0.1 V0.09 % + 5
    1000 V1 V0.09 % + 5
    Vac (45 Hz to 500 Hz with 800 Hz filter)600 V0.1 V2 % + 10
    Frequency (displayed with Vac and Aac)2500 Hz0.1 Hz0.5 % + 8
    AC voltage ripple (20 KHz Max)600 mV0.1 mV3 % + 20
    6000 mV1 mV3 % + 10
    Adc/Aac (with accessory Fluke i410)400 A1 A3.5 % + 2
    Temperature0 °C to 60 °C1 °C2 °C (4 °F)
    Meter mode999 records for each measurement position with time stamp
    Sequence modeUp to 100 profiles and 100 profile templates (Each profile stores up to 450 batteries) with time stamp

    1The measurement is based on ac injection method. The injected source signal is <100 mA, 1 kHz.
    2 Trigger level VAC: 10 mV, Aac: 10 A

    BT510BT520BT521
    Resistance (mΩ)
    Battery voltage
    Voltage dc
    Voltage ac and frequency (Hz)
    Ripple volt
    Temperature of negative battery post
    DC and ac current (and frequency)
    DMM mode
    Sequence mode
    Discharge measurement mode
    Automatic measurement save
    Wireless communication
    Memory view
    Size (HxWxD)22 cm x 10.3 cm x 5.8 cm (9 in x 4 in x 2 in)
    Weight850 g (1.9 lb)
    Screen dimensions7.7 cm x 5.6 cm (3 in x 2.2 in)
    InterfaceUSB mini
    Operating temperature0 °C to 40 °C
    Storage temperature-20 °C to 50 °C
    Lithium-ion battery charging temperature0 °C to 40 °C
    Operating humidityNon-condensing (10 °C)
    <=80 % RH (at 10 °C to 30 °C)
    <=75 % RH (at 30 °C to 40 °C)
    Operating altitudeSea level to 2000 meters
    Storage altitudeSea level to 12,000 meters
    IP ratingIP40
    RadioFCC Class A
    Vibration requirementsMIL-PRF-28800F: Class 2
    Drop test requirements1 meter
    Temperature coefficientsAdd 0.1 x specified accuracy for each degree C above 28 °C or below 18 °C
    Safety compliance600 V CAT III
    EMCIEC 61326
    ROHSChina, Europe
    Protection Class 2Pollution Degree II
    Battery complianceUN38.3
    UL2054
    IEC62133
    2G per IEC68-2-26, 25G, and 29
    • Battery analyzer
    • 4-wire test pin (set)
    • BTL10 Basic Test Lead (set)
    • TL175 TwistGuardª Test Leads with adapter
    • BP500 lithium-ion battery
    • BC500 AC charger
    • Mini-USB cable
    • Shoulder strap
    • Belt strap
    • Magnetic hanging strap
    • FlukeView¨ Battery Management Software
    • Soft carrying case
    • Spare fuses (2)
    • Zero Ohm Calibration Resistor