    FLUKE 717 1G Pressure Calibrator (68.9 mbar)

    # 717 1G

    • Measure pressure, 0.05% of full scale with internal sensor up to 5000 psi/345 bar sensor (5000G model)
    • Measure mA with 0.015% accuracy and 0.001 mA resolution, while sourcing 24 V loop power
    • Measure pressure to 10,000 psi/700 bar using one of 29 Fluke 700Pxx Pressure Modules
    • Measure pressure, 0.05% of full scale with internal sensor up to 5000 psi/345 bar sensor (5000G model)
    • Measure mA with 0.015% accuracy and 0.001 mA resolution, while sourcing 24 V loop power
    • Measure pressure to 10,000 psi/700 bar using one of 29 Fluke 700Pxx Pressure Modules
    • 1/8 NPT female pressure fitting
    • Compatible with non-corrosive Gases and liquids
    • Select eleven different engineering units
    • Zero, min, max, and hold functions
    • Calibrate P/I instruments with simultaneous pressure and current measurement
    • Pressure switch test function captures set, reset and Deadband values of a pressure switch
    • Error % calculation of mA measurements for quick pass-fail decisions
    • Long lasting battery life
    • Holster features test lead storage
    • Compatible with Toolpack magnetic hanging system
    • New switch test

     

    Measurement Accuracy
    Pressure
    717 Series
    Measure Pressure(internal sensor)
    Accuracy0.05% full scale
    FunctionsZero, Min, Max, Hold, Damp
    Note Gasses / liquids (non-corrosive)
    Fluke 717 1G
    Range-1 to 1 PSI, (-68.9 mbar to 68.9 mbar, -83 to 6.89 kPa)
    Resolution0.0001 PSI, 0.001 mbar, 0.0001 kPa
    Over Pressure5 X Full Scale
    Fluke 717 Series with Pressure Modules
    Measure Pressure(via pressure module connector using optional Pressure Modules)
    Range29 pressure modules, 0-1 inH20 to 10,000 PSI, 2.5 mbar to 700 bar ranges. Over pressure per pressure module specs
    ResolutionPer pressure module specs
    Accuracyper pressure module specs
    FunctionsZero, Min, Max, Hold, Damp
    Current
    Range:0 to 24 mA (-25% to 125%)
    Resolution0.001 mA
    Accuracy0.015% + 2 counts

    Specifications
    Loop Power
    Range24 V dc
    Accuracy+/- 10%
    Note: Drive; 20 mA into 1000 ohms for battery >6.8V; 700 W for battery 5.8 to 6.8 V
    Display
    Clear 5 digit LCD

    Environmental Specifications
    Operating Temperature
    -10 �C to 55 �C
    Storage Temperature
    -40 �C to 60 �C
    Humidity (Without Condensation)
    95% (10 �C to 30 �C)
    75% (30 �C to 40 �C)
    45% (40 �C to 50 �C)
    35% (50 �C to 55 �C)
    Operating Altitude
    3,000 M max

    Safety Specifications
    Safety
    CSA C22.2 No. 1010.1:1992

    Mechanical & General Specifications
    Size
    201 mm L x 98 mm W x 52 mm (7.93in. L x 3.86in. W X 2.06in.)
    Weight
    22 oz, approximately 600G with holster
    Warranty
    3 years
    Shock & Vibration
    Random, 2G, 5-500 Hz
    1m drop test
    Battery type
    Single 9V battery ANSI/NEDA 1604A or IEC 6LR619V alkaline
    • – Test Lead Set
    • – Alligator Test Clip Set
    • – Protective Yellow Holster with Test Lead Storage
    • – 9V Battery
    • – NIST Calibration Report and Data
    • – User Manual

    Provide us your contact detailsone of our product experts will contact you to discuss your needs or schedule a demonstration at a time that suits

    Product selected: Model #







      *Demonstrations can only be scheduled within the UAE

      Sign up to stay in the know-how of our latest products, updates, special offers, and more.

      • Subscription Form