• Store Locator
  • Schedule a
    Demo
  • Add products to your Toolbox to save it for requesting a quote while you keep browsing for other products to complete your list.

    My
    Toolbox
  • expression
    Create a Requisition

    FLUKE 319 True RMS Clamp Meter

    # 319

    • Unique 40A high-precision low current measurement–0.01A high-resolution, 1.6% high-precision measurement
    • The clamps are slim, lightweight, and portable, making them ideal for use in small, confined spaces
    • The large backlight display facilitates readings in dark environments
    FLUKE
    • FLUKE
    • 319

    Quantity:

    - +
      ADD TO MY TOOLBOX
    Where to buy this product?
    • Unique 40A high-precision low current measurement–0.01A high-resolution, 1.6% high-precision measurement
    • The clamps are slim, lightweight, and portable, making them ideal for use in small, confined spaces
    • The large backlight display facilitates readings in dark environments
    • Starting current (inrush) functionality (319) allows measurement of the starting current of electrical and lighting equipment, for example. (319)
    • Current frequency measurement
    • Precision down to 0.01A and 0.1V
    • 1000A/600A AC/DC current measurement (319/317)
    • 600V AC/DC voltage measurement
    • 4000? resistance measurement
    • Continuity beeper
    • Auto off function enhances battery life, meaning the instrument can work when you need it screen store ‘hold’ function for capturing a measurement result on the screen
    • One year warranty
    General specifications
    Digital display 6000 count resolution
    Low battery Indication Displays a signal when the batteries are below their required voltage
    Power source Three AAA IEC LR03 batteries
    Clamp opening size 1.45 in (37 mm)
    Jaw diameter 1.45 in (37 mm)
    Dimensions (L x W x H) 6.39 x 2.29 x 1.20 in
    (162.4 x 58.25 x 30.5 mm)
    Weight Approximately 13.5 oz (384 g) (batteries included)
    Auto range Available in Ohms
    Safety CE
    EN/IEC 61010-1 and IEC 61010-2-032
    Measurement Category: 600V CAT III
    317 Electrical specifications
    Current AC Range 40.00 A, 600.0 A
    Resolution 0.01 A, 0.1 A
    Accuracy 1.6% ±6 digit (50-60 Hz) {40 A}
    2.5% ±8 digit (60-500 Hz) {40 A}
    1.5% ±5 digit (50-60 Hz) {600 A}
    2.5% ±5 digit (60-500 Hz) {600 A}
    Crest Factor add 2% into spec for CF > 2 3.0 Max @ 500 A, 2.5 Max @ 600 A
    AC response rms
    Current DC Range 40.00 A, 600.0 A
    Resolution 0.01 A, 0.1 A
    Accuracy 1.6% ±6 digit (40 A)
    1.5% ±5 digit (600 A)
    Voltage AC Range 600.0 V
    Resolution 0.1 V
    Accuracy 1.5% ±5 digit (20-500Hz)
    AC response rms
    Voltage DC Range 600.0 V
    Resolution 0.1 V
    Accuracy 1% ±4 digit
    Resistance Range 400.0 Ω, 4000 Ω
    Resolution 0.1 Ω, 1 Ω
    Accuracy 1% ±5 digit
    Continuity ≤ 30 Ω
    Inrush Integration time N/A
    Frequency Range N/A
    Accuracy N/A
    Trigger Level N/A
    319 Electrical specifications
    Current AC Range 40.00 A, 600.0 A, 1000 A
    Resolution 0.01 A, 0.1 A, 1 A
    Accuracy 1.6% ±6 digit (50-60 Hz) {40 A}
    2.5% ±8 digit (60-500 Hz) {40 A}
    1.5% ±5 digit (50-60 Hz) {600/1000 A}
    2.5% ±5 digit (60-500 Hz) {600/1000 A}
    Crest Factor add 2% into spec for CF > 2 3.0 Max @ 500 A, 2.5 Max @ 600 A, 1.4 Max @ 1000 A
    AC response rms
    Current DC Range 40.00 A, 600.0 A, 1000 A
    Resolution 0.01 A, 0.1 A, 1 A
    Accuracy 1.6% ±6 digit (40 A)
    1.5% ±5 digit (600/1000 A)
    Voltage AC Range 600.0 V
    Resolution 0.1 V
    Accuracy 1.5% ±5 digit (20-500Hz)
    AC response rms
    Voltage DC Range 600.0 V
    Resolution 0.1 V
    Accuracy 1% ±4 digit
    Resistance Range 400.0 Ω
    4000 Ω
    Resolution 0.1 Ω
    1 Ω
    Accuracy 1% ±5 digit
    Continuity ≤ 30 Ω
    Inrush Integration time 100 ms
    Frequency Range 5.0 – 500.0 Hz
    Accuracy 0.5% ±5 digit
    Trigger Level 10 – 100 Hz ≥ 5 A, 5 – 10 Hz, 100 – 500 Hz ≥ 10 A
    The accuracy specifications aply at 73 °F ±41 °F (23 °C ±5 °C)
    Below 64 °F and above 82 °F (18 °C and above 28 °C) accuracy degrades at (0.1) times specification per °C.
    True rms for ac V and ac A accuracy is specified from 5% to 100% of range.
    Environmental specifications
    Operating temperature 14°F to 122°F (-10 °C to 50 °C)
    Storage temperature -40 °F to 140 °F (-40 °C to 60 °C)
    Operating humidity Non-condensing (< 50 °F) (< 10 °C)
    90% RH (50 °F to 86 °F) (10 °C to 30 °C)
    75% RH (86 °F to 104 °F) (30 °C to 40 °C)
    45% RH (104 °F to 122 °F) (40 °C to 50 °C)
    (Without condensation)
    Operating altitude 1 mile (2000 meters) above mean sea level
    Storage altitude 7 miles (12,000 meters) above mean sea level
    IP Rating IP40
    Vibration requirements Random MIL-PRF-28800F Class 2, 5-500 Hz, 30 minutes per axis
    Drop test requirements 3 ft (1 m) drop test, six sides, oak floor
    EMI, RFI, EMC Instrument unspecified for use in EMC field ≥ 0.1 V/m
    Temperature coefficients 0.1x (specified accuracy)/ °C
    (<64 °F or > 82° F)
    (<18 °C or > 28 °C)

    Provide us your contact detailsone of our product experts will contact you to discuss your needs or schedule a demonstration at a time that suits

    Product selected: Model #







    *Demonstrations can only be scheduled within the UAE