    FLUKE 902 FC TRMS HVAC Clamp Meter 600V

    # 902 FC

    • A wireless Fluke Connect®-enabled clamp meter designed specifically for the needs of HVAC technicians
    • Offers 200 µA DC current measurements to measure flame rod
    • Extends resistance range to measure thermistors up to 60kΩ

    Fluke 902 FC True-RMS HVAC Clamp Meter helps HVAC technicians work more efficiently on the work site.

    The Fluke 902 FC Clamp Meter, with Fluke Connect wireless connectivity, can help HVAC technicians improve productivity in the field. The rugged dual-rated CAT III 600 V, CAT IV 300 V meter equips you to perform many essential HVAC system measurements: microamps for testing pilot light sensors; resistance up to 60 kΩ; AC current and AC/DC voltage; capacitance; and contact temperature, all with just one tool. Plus its small form factor makes it easy to hang on to and navigate in tight work spaces.

     

    Part of the Fluke Connect wireless family

    As part of the Fluke Connect family, the 902 FC can transmit measurements to a smartphone or tablet for later, detailed analysis. No need to write down the results. Trend and monitor measurements live on your phone screen, and upload those measurements to the cloud. Combine measurement data from multiple Fluke Connect test tools to create and share reports from the job site via email, and collaborate in real time with other colleagues with ShareLive™ video calls or email.

     

    The 902 FC can also decrease the frequency of wearing personal protective equipment (PPE) when working on high voltage/current panels. Simply turn off the panel. Verify that it is de-energized using standard safety procedures. Place the clamp and synch it to a smartphone. Close the panel, reenergize it, and take measurements from a safe distance.

     

    • A wireless Fluke Connect®-enabled clamp meter designed specifically for the needs of HVAC technicians
    • Offers 200 µA DC current measurements to measure flame rod
    • Extends resistance range to measure thermistors up to 60kΩ
    • Captures flue gas temperature
    • Measures start and run motor capacitors
    • Measures variable frequency drive performance
    • Ergonomic design fits in your hand and can be used while wearing personal protective equipment
    • Large, easy-to-read backlit display improves readings in low light settings
    • Comes with a TPAK magnetic hanging strap, batteries soft carrying case, and three-year warrant
    • Connects to your smartphone via Fluke Connect so you can read measurements at a safer distance
    • Measures AC current to 600 A and AC and DC voltage to 600 V
    • Measures capacitance to 1000 µF and DC current to 200 µA
    • Measures temperature from -10 °C to 400 °C (14 °F to 752 °F)
    • Offers True-RMS voltage and current measurements to accurately measure non-linear signals
    • Measures resistance to 60 kΩ
    • Offers Min/Max recording to capture variations automatically
    • Runs on two AA alkaline batteries
    Function
    A ac (via Jaw)
    Resolution0.01/0.1 A
    Accuracy2.0% ±5 digit (45-65 Hz)
    2.5% ±5 digit (65-400 Hz)
    Range60.00/600.0 A
    Crest Factor (50Hz or 60Hz)2.5 MIN@220 A
    3.0 MIN@180 A
    > 1.4 MIN@600 A
    Add 2% for CF>400 A
    V ac
    Resolution0.1 V
    Accuracy1.5% ±5 digits
    Range600.0 V
    V dc
    Resolution0.1 V
    Accuracy1.5% ±5 digits
    Range600.0 V
    Ohms
    Resolution0.1/1/10
    Accuracy1% ±5 digits
    Range600/6000/60.00 kΩ
    Capacitance
    Resolution0.1/1 µF
    Accuracy1% ±4 digits
    Range100.0/1000 µF
    µA
    Resolution0.1 µA
    Accuracy1% ±5 digits
    Range200 µA
    Contact temperature
    Resolution0.1 C/F
    Accuracy1% ±8 digits
    Range-40 to 400 °C (-40 °F to 752 °F)
    Continuity beeper
    Beeper volume75 dBA nom. 15 cm. from case front
    On threshold<=30 Ω
    Mechanical and General Specifications
    Maximum voltage between any terminal and earth ground1000 V
    Battery type2 AA alkaline batteries, NEDA 15A, IEC LR6
    TemperatureOperating: -10 °C to +50 °C (14 °F to +122 °F)
    Storage: -40 °C to +60 °C (-40 °F to +140 °F)
    Operating humidityNon condensing (< 10 °C [50 °F]), ≤90 % RH (at 10 °C to 30 °C [50 °F to 86 °F]), ≤75 % RH (at 30 °C to 40 °C (86 °F to 104 °F)), ≤45 % RH (at 40 °C to 50 °C (104 °F to 122 °F))
    AltitudeOperating: 3,000 m (9,842 ft)
    Storage: 12,000 m (39,370 ft)
    Dimensions230 x 83.7 x 45.4mm (9.06 x 3.30 x 1.39 in)
    Weight (meter only)419 g (15 oz)
    SafetyIEC 61010-1, Pollution Degree 2
    IEC 61010-2-032: CAT III 1000 V / CAT IV 600 V
    IEC 61010-2-033: CAT III 1000 V / CAT IV 600 V
    IP RatingIEC 60529: IP30, non-operating
    Radio Frequency CertificationFCC ID:T68-FBLE IC:6627A-FBLE
    Electromagnetic Compatibility (EMC)International: IEC 61326-1: Portable, Electromagnetic Environment, IEC 61326-2-2 CISPR 11: Group 1, Class A Korea (KCC): Class A Equipment (Industrial Broadcasting & Communication Equipment) USA (FCC): 47 CFR 15 subpart B. This product is considered an exempt device per clause 15.103.
    Temperature coefficientsAdd 0.1 × specified accuracy for each degree C above 28 °C or below 18 °C
    • TL75 test leads (1 pair)
    • 80BK integrated DMM temperature probe (1)
    • AA alkaline batteries (2)
    • Soft carrying case
    • User’s manual
    • Statement of calibration