    FLUKE 1587FC Insulation Multimeters with Fluke Connect

    # 1587FC

    • 1587 FC; perform insulation tests; plus a wide-range of DMM tasks with confidence and ease
    • Memory storage through Fluke Connect Measurements app
    • Temperature Compensation through Fluke Connect Measurements app
    • Pl/DAR measurements with TrendItª graphs
    • Memory storage through Fluke Connect Measurements app
    • Temperature Compensation through Fluke Connect Measurements app
    • VFD low-pass filter for accurate motor drive measurements
    • Insulation test voltages 50 V; 100 V; 250 V; 500 V; 1000 V
    • Insulation test voltages 500 V; 1000 V
    • Insulation test: 0.01 M? to 2.0 G?
    • Insulation test: 0.1 M? to 600 M?
    • Auto-discharge of capacitive voltage
    • Insulation test smoothing reading
    • Frequency / Capacitance / Diode test / Temperature
    • Min/Max / AC/DC Voltage / DC Millivolts / AC/DC Milliamps
    • Resistance (0.1 ? to 50 M?) / Continuity / Auto power off
    • Remote probe; test leads; alligator clips; K-type thermocouple; hard case
    Electrical Specifications
    AC voltage measurement
    Range
    600.0 mVResolution0.1 mV
    Accuracy 50 Hz to 60 Hz ±(% of Rdg + Counts)±(1% + 3)
    Accuracy 60 Hz to 5000 Hz ±(% of Rdg + Counts)±(2% + 3)
    6.000 VResolution0.001 V
    Accuracy 50 Hz to 60 Hz ±(% of Rdg + Counts)±(1% + 3)
    Accuracy 60 Hz to 5000 Hz ±(% of Rdg + Counts)±(2% + 3)
    60.00 VResolution0.01 V
    Accuracy 50 Hz to 60 Hz ±(% of Rdg + Counts)±(1% + 3)
    Accuracy 60 Hz to 5000 Hz ±(% of Rdg + Counts)±(2% + 3)
    600.0 VResolution0.1 V
    Accuracy 50 Hz to 60 Hz ±(% of Rdg + Counts)±(1% + 3)
    Accuracy 60 Hz to 5000 Hz ±(% of Rdg + Counts)±(2% + 3)¹
    1000 VResolution1 V
    Accuracy 50 Hz to 60 Hz ±(% of Rdg + Counts)±(2% + 3)
    Accuracy 60 Hz to 5000 Hz ±(% of Rdg + Counts)±(2% + 3)¹
    ¹ 1 kHz bandwidth
    Low-Pass Filter Voltage
    Range
    600.0 mVResolution0.1 mV
    Accuracy 50 Hz to 60 Hz ±(% of Rdg + Counts)±(1% + 3)
    Accuracy 60 Hz to 400 Hz ±(% of Rdg + Counts)+(2% + 3), -(6% – 3)
    6.000 VResolution0.001 V
    Accuracy 50 Hz to 60 Hz ±(% of Rdg + Counts)±(1% + 3)
    Accuracy 60 Hz to 400 Hz ±(% of Rdg + Counts)+(2% + 3), -(6% – 3)
    60.00 VResolution0.01 V
    Accuracy 50 Hz to 60 Hz ±(% of Rdg + Counts)±(1% + 3)
    Accuracy 60 Hz to 400 Hz ±(% of Rdg + Counts)+(2% + 3), -(6% – 3)
    600.0 VResolution0.1 V
    Accuracy 50 Hz to 60 Hz ±(% of Rdg + Counts)±(1% + 3)
    Accuracy 60 Hz to 400 Hz ±(% of Rdg + Counts)+(2% + 3), -(6% – 3)
    1000 VResolution1 V
    Accuracy 50 Hz to 60 Hz ±(% of Rdg + Counts)±(2% + 3)
    Accuracy 60 Hz to 400 Hz ±(% of Rdg + Counts)+(2% + 3), -(6% – 3)
    DC Voltage Measurement
    RangeResolutionAccuracy ±(% of Rdg + Counts)
    6.000 V dc0.001 V±(0.09% + 2)
    60.00 V dc0.01 V±(0.09% + 2)
    600.0 V dc0.1 V±(0.09% + 2)
    1000 V dc1 V±(0.09% + 2)
    Input impedance10 MΩ (nominal), <100 pF
    Normal mode rejection ratio>60 dB @ 50 Hz or 60 Hz
    Common mode rejection ratio>120 dB @ dc, 50 Hz or 60 Hz (1 k unbalance)
    Accuracies apply to ± 100% of range
    DC Millivolts Measurement
    RangeResolutionAccuracy ±(% of Rdg + Counts)
    600.0 mVdc0.1 mV±(0.1% + 1)
    DC and AC Current Measurement
    AC 45 Hz to 1000 Hz
    Range400 mA
    Resolution0.1 mA
    Accuracy ±(% of Rdg+Counts)±(1.5% + 2)¹
    Burden voltage (Typical)2 mV/mA
    Range60 mA
    Resolution0.01 mA
    Accuracy ±(% of Rdg+Counts)±(1.5% + 2)¹
    Burden voltage (Typical)2 mV/mA
    DC
    Range400 mA
    Resolution0.1 mA
    Accuracy ±(% of Rdg+Counts)±(0.2% + 2)
    Burden voltage (Typical)2 mV/mA
    Range60 mA
    Resolution0.01 mA
    Accuracy ±(% of Rdg+Counts)±(0.2% + 2)
    Burden voltage (Typical)2 mV/mA
    Overload600 mA for 2 minutes maximum
    Fuse protection for mA input0.44 mA, 1000 V, IR 10 kA
    AC conversionInputs are ac-coupled and calibrated to the rms value of sine wave input
    Conversions are true-rms responding and specified from 5% to 100% of range. Input signal crest factor can be up to 3 up to 300 mA, decreasing linearly to crest factor ≤1.5 at 600 mA. For non-sinusoidal waveforms add +(2% reading + 2% FS) typical, for a crest factor up to 3.
    ¹ 1 kHz bandwidth
    Ohms Measurement
    RangeResolutionAccuracy +(% of Rdg+Counts)¹
    600.0 Ω0.1 Ω±(0.9% + 2)
    6.000 kΩ0.001 kΩ±(0.9% + 2)
    60.00 kΩ0.01 kΩ±(0.9% + 2)
    600.0 kΩ0.1 KΩ±(0.9% + 2)
    6.000 MΩ0.001 MΩ±(0.9% + 2)
    50.0 MΩ ²0.01 MΩ±(1.5% + 3)
    Overload protection1000 V rms or dc
    Open circuit test voltage<8.0 V dc
    Short circuit current<1.1 mA
    ¹ Accuracies apply from 0% to 100% of range
    ² Up to 80% relative humidity
    Diode Test
    Diode test indicationDisplay voltage drop: 0.6 V at1.0 mA nominal test current:
    Accuracy±(2% + 3)
    Continuity Test
    Continuity indicationContinuous audible tone for testresistance below 25 Ω and off above 100 Ω. Maximum Reading; 1000 Ω
    Open circuit voltage<8.0 V
    Short circuit current1.0 mA typical
    Overload protection1000 V rms
    Response time>1 m sec
    Frequency Measurement
    RangeResolutionAccuracy ±(% of Rdg+Counts)
    99.99 Hz0.01 Hz±(0.1% + 1)
    999.9 Hz0.1 Hz±(0.1% + 1)
    9.999 kHz0.001 kHz±(0.1% + 1)
    99.99 kHz0.01 kHz±(0.1% + 1)
    Frequency Counter Sensitivity
    600.0 mV acV ac Sensitivity (RMS Sine Wave)¹  5 Hz to 20 kHz100.0 mV
    V ac Sensitivity (RMS Sine Wave)¹  20 kHz to 100 kHz150.0 mV
    DC Trigger Levels¹ to 20 kHz²NA
    6.0 VV ac Sensitivity (RMS Sine Wave)¹  5 Hz to 20 kHz1.0 V
    V ac Sensitivity (RMS Sine Wave)¹  20 kHz to 100 kHz1.5 V
    DC Trigger Levels¹ to 20 kHz²-400.0 mV and 2.5 V
    60.0 VV ac Sensitivity (RMS Sine Wave)¹  5 Hz to 20 kHz10.0 V
    V ac Sensitivity (RMS Sine Wave)¹  20 kHz to 100 kHz36.0 V
    DC Trigger Levels¹ to 20 kHz²1.2 V and 4.0 V
    600.0 VV ac Sensitivity (RMS Sine Wave)¹  5 Hz to 20 kHz100.0 V
    V ac Sensitivity (RMS Sine Wave)¹  20 kHz to 100 kHz
    DC Trigger Levels¹ to 20 kHz²12.0 V and 40.0 V
    1000.0 VV ac Sensitivity (RMS Sine Wave)¹  5 Hz to 20 kHz300.0 V
    V ac Sensitivity (RMS Sine Wave)¹  20 kHz to 100 kHz
    DC Trigger Levels¹ to 20 kHz²12.0 V and 40.0 V
    ¹ Maximum input for specified accuracy = 10x range (1000 V max). Noise at low frequencies and amplitudes may affect accuracy
    ² Usable to 100 kHz with full scale input
    Capacitance
    RangeResolutionAccuracy ±(% of Rdg+Counts)
    1000 nF1 nF±(1.2% + 2)
    10.00 μF0.01 μF±(1.2% + 2)
    100.0 μF0.1 μF±(1.2% ±90 counts)
    9999 μF1 μF±(1.2% ±90 counts)
    Temperature Measurement
    RangeResolutionAccuracy ±(% of Rdg+Counts)¹
    -40 ° C to 537 ° C0.1 °C±(1% + 10 counts)
    -40 ° F to 998 ° F0.1 °F±(1% + 18 counts)
    ¹ Accuracies apply following 90 minutes settling time after a change in the ambient temperature of the instrument
    Insulation Specifications
    Measurement range0.01 MΩ to 2 GΩ
    Test voltages50, 100, 250, 500, 1000 V
    Test voltage accuracy+20%, -0%
    Short-circuit test current1 mA nominal
    Auto dischargeDischarge time <0.5 second for C = 1 μF or less
    Live circuit detectionInhibit test if terminal voltage > 30 V prior to initialization of test
    Maximum capacitive loadOperable with up to 1 μF load
    Output Voltage
    50 V (0% to +20%)Display range0.01 to 6.00 MΩ
    Resolution0.01 MΩ
    Test current1 mA @ 50 kΩ
    Resistance accuracy ±(% of Rdg + Counts)±(3% + 5 counts)
    Display range6.0 to 50.0 MΩ
    Resolution0.1 MΩ
    Test current1 mA @ 50 kΩ
    Resistance accuracy ±(% of Rdg + Counts)±(3% + 5 counts)
    100 V (0% to +20%)Display range0.01 to 6.00 MΩ
    Resolution0.01 MΩ
    Test current1 mA @ 100 kΩ
    Resistance accuracy ±(% of Rdg + Counts)±(3% + 5 counts)
    Display range6.0 to 60.0 MΩ
    Resolution0.1 MΩ
    Test current1 mA @ 100 kΩ
    Resistance accuracy ±(% of Rdg + Counts)±(3% + 5 counts)
    Display range60 to 100 MΩ
    Resolution1 MΩ
    Test current1 mA @ 100 kΩ
    Resistance accuracy ±(% of Rdg + Counts)±(3% + 5 counts)
    250 V (0% to +20%)Display range0.1 to 60.0 MΩ
    Resolution0.1 MΩ
    Test current1 mA @ 250 kΩ
    Resistance accuracy ±(% of Rdg + Counts)±(1.5% + 5 counts)
    Display range60 to 250 MΩ
    Resolution1 MΩ
    Test current1 mA @ 250 kΩ
    Resistance accuracy ±(% of Rdg + Counts)±(1.5% + 5 counts)
    500 V (0% to +20%)Display range0.1 to 60.0 MΩ
    Resolution0.1 MΩ
    Test current1 mA @ 500 kΩ
    Resistance accuracy ±(% of Rdg + Counts)±(1.5% + 5 counts)
    Display range60 to 500 MΩ
    Resolution1 MΩ
    Test current1 mA @ 500 kΩ
    Resistance accuracy ±(% of Rdg + Counts)±(1.5% + 5 counts)
    1000 V (0% to +20%)Display range0.1 to 60.0 MΩ
    Resolution0.1 MΩ
    Test current1 mA @ 1 MΩ
    Resistance accuracy ±(% of Rdg + Counts)±(1.5% + 5 counts)
    Display range60 to 600 MΩ
    Resolution1 MΩ
    Test current1 mA @ 1 MΩ
    Resistance accuracy ±(% of Rdg + Counts)±(1.5% + 5 counts)
    Display range0.6 to 2.0 GΩ
    Resolution100 MΩ
    Test current1 mA @ 1 MΩ
    Resistance accuracy ±(% of Rdg + Counts)±(10% + 3 counts)
    General Specifications
    Maximum voltage applied to any terminal and common1000 V
    Storage temperature-40 °C to 60 °C (-40 °F to 140 °F)
    Operating temperature-20 °C to 55 °C (-4 °F to 131 °F)
    Temperature coefficient0.05 x (specified accuracy) per °C for temperatures <18 °C or >28 °C (<64 °F or >82 °F)
    Relative humidityNoncondensing
    0% to 95% @ 10 °C to 30 °C (50 °F to 86 °F)
    0% to 75% @ 30 °C to 40 °C (86 °F to 104 °F)
    0% to 40% @ 40 °C to 55 °C (104 °F to 131 °F)
    VibrationRandom, 2 g, 5-500 Hz per MIL-PRF-28800F, Class 2 instrument
    Radio frequency communication2.4 GHz ISM Band
    Radio frequency certificationFCC: T68-FBLE, IC: 6627A-FBLE
    Electromagnetic Compatibility
    InternationalIEC 61326-1:Portable Electromagnetic Environment; IEC 61326-2-2 CISPR 11: Group 1, Class A
    Group 1: Equipment has intentionally generated and/or uses conductively-coupled radio frequency energy that is necessary for the internal function of the equipment itself.
    Class A: Equipment is suitable for use in all establishments other than domestic and those directly connected to a low-voltage power supply network that supplies buildings used for domestic purposes.  There may be potential difficulties in ensuring electromagnetic compatibility in other environments due to conducted and radiated disturbances.
    Emissions that exceed the levels required by CISPR 11 can occur when the equipment is connected to a test object. The equipment may not meet the immunity requirements of this standard when test leads and/or test probes are connected.
    Korea (KCC)Class A Equipment (Industrial Broadcasting & Communication Equipment)
    Class A: Equipment meets requirements for industrial electromagnetic wave equipment and the seller or user should take notice of it. This equipment is intended for use in business environments and not to be used in homes.
    USA (FCC)47 CFR 15 subpart B. This product is considered an exempt device per clause 15.103.
    Enclosure protectionIEC 60529: IP40 (non-operating)
    Safety
    IEC 61010-1Pollution Degree 2
    IEC 61010-2-033CAT IV 600 V / CAT III 1000 V
    BatteriesFour AA batteries (NEDA 15A or IEC LR6)
    Battery lifeMeter use 1000 hours; Insulation test use: Meter can perform at least 1000 insulation tests with fresh alkaline batteries at room temperature. These are standard tests of 1000 V into 1 MΩ with a duty cycle of 5 seconds on and 25 seconds off.
    Size (H x W x L)5.0 x 10.0 x 20.3 cm (1.97 x 3.94 x 8.00 in)
    Weight550 g (1.2 lb)
    AltitudeOperating2000 m
    Storage12,000 m
    Over-range capability110% of range except for capacitance which is 100%
    Frequency overload protection<107 V Hz
    Fuse protection for mA input0.44A, 1000 V, IR 10 kA
    • Remote probe
    • Test leads
    • Alligator clips
    • K-type thermocouple
    • Hard case
    • User documentation

    Provide us your contact detailsone of our product experts will contact you to discuss your needs or schedule a demonstration at a time that suits

    Product selected: Model #







      *Demonstrations can only be scheduled within the UAE

      Sign up to stay in the know-how of our latest products, updates, special offers, and more.

      • Subscription Form