• Store Locator
  • Schedule a
    Demo
  • Add products to your Toolbox to save it for requesting a quote while you keep browsing for other products to complete your list.

    My
    Toolbox
  • Create a Requisition

    FLUKE 773 Advanced Milliamp Process Clamp-Meter

    # 773

    • Loop calibrator that measures 4 to 20 mA signals without breaking the loop
    • Features best in class 0.2% accuracy
    • Sources 4 to 20 mA signals for testing control system I/O or I/Ps

    Fluke 773 Milliamp Process Clamp Meter saves time and money by measuring output signals without shutting down the system

     

    The Fluke 773 milliamp clamp meter is accurate and versatile. It saves time and money by measuring 4–20 mA signals five times faster than with traditional DMMs, and without breaking the loop. That means you can troubleshoot a live device without having to power down and possibly miss something going on in the process.

     

    The 773 is ideal for troubleshooting transmitters, valves, and programmable logic controllers (PLCs) found in process plants. It measures low level dc current and correlates process indication with a real physical value. And it measures up to 99.0 mA non-contact, including 10 to 50 mA signals in older control systems.

     

    The 773 also sources and measures dc voltage, so it can be used to troubleshoot voltage input and output devices. You can detach the clamp section of the meter and use it as a remote jaw, connected to the main body by an extension cable to make it easier to take measurements in tight spaces. Plus, automatic power-off features save battery life so you can work longer without changing the batteries.

     

    Other useful features:

    • Sources DC voltage to test input devices that accept a 1-5V or 0 to 10V signal
    • Simultaneously measures the mA signal with the clamp and sources a mA signal
    • Measures mA signals for PLC and control system analog I/O
    • Simulates 4-20 mA signals for testing control system I/O
    • Features a detachable clamp with extension cable for measurements in tight locations
    • Extends battery life with auto-off and backlight timeout
    • Captures and displays changing measurements with Hold function
    • Measures 4 to 20 mA signals with in-circuit measurement
    • Includes simultaneous mA in-circuit measurement with 24V loop power for powering and testing transmitters
    • Offers mA or voltage output linear ramp or 25% step output
    • Provides scaled mA output to provide a continuous mA signal that corresponds to the 4 to 20 mA signal measured by the mA clamp
    • Enables milliamp signal logging to a separate logging device without breaking the loop
    • Applies a mA input signal to a device and measure its’ 4-20 mA output on devices such as valves or mA isolators
    • Dual backlit display with both mA measurement and percent of 4 to 20 mA span
    • Measurement Spotlight to illuminate hard to see wires in dark enclosure
    • Measures 10 to 50 mA signals in older control systems using the 99.9 mA range
    • Automatically changes the 4 to 20 mA output for remote testing

     

    Key features

    • Loop calibrator that measures 4 to 20 mA signals without breaking the loop
    • Features best in class 0.2% accuracy
    • Sources 4 to 20 mA signals for testing control system I/O or I/Ps
    • Delivers 0.01 mA resolution and sensitivity
    • Measures DC voltage to verify 24V power supplies or voltage I/O signals
    Specifications
    Diameter of measurable conductor0.177″ or 4.5 mm max
    Operating temperature-10 to 50ºC
    Storage temperature-25 to 60ºC
    Operating humidity< 90% @ <30ºC, < 75% @ 30 to 55ºC
    Operating altitude0 to 2000 m
    IP ratingIP 40
    Size44 x 70 x 246 mm (2 7/8 x 5 ¾ x 11 5/8 in)
    Weight410 g, (14.4 oz)
    VibrationRandom 2 g, 5 to 500 Hz
    Shock1 meter drop test (except the jaw)
    EMI/RFIMeets EN61326-1
    For current measurement w/ JAW, add 1mA to specification for EMC field strengths of 1V/m up to 3V/m.
    Temperature coefficient0.01% ºC
    (< 18ºC or > 28ºC)
    Power, battery life(4) AA 1.5 V Alkaline, IEC LR6, 12 hours in mA source into 500 ohms
    WarrantyThree years for electronics
    One year for cable and clamp assembly
    Functional Specifications
    mA measurement
    (measured by clamp)
    Resolution / range0 to 20.99 mA
    Accuracy0.2% + 5 counts
    Resolution / range21.0mA to 100.0 mA
    Accuracy1% + 5 counts
    mA measurement (measured in series with test jacks)Resolution / range0 to 24.00 mA
    Accuracy0.2% + 2 counts
    mA source (maximum mA drive: 24 mA into 1,000 ohms)Resolution / range0 to 24.00 mA
    Accuracy0.2% + 2 counts
    mA simulate (maximum voltage 50 V dc)Resolution / range0 to 24.00 mA
    Accuracy0.2% + 2 counts
    Voltage source (2 mA maximum drive current)Resolution / range0 to 10.00 V DC
    Accuracy0.2% + 2 counts
    Voltage measureResolution / range0 to 30.00 V DC
    Accuracy0.2% + 2 counts
    • Four AA alkaline batteries (installed)
    • Soft carrying case
    • TL75 test leads
    • AC 72 detachable clip
    • TL 940 mini hook test leads
    • Instruction sheet
    • Hanging tool with hook and loop strap

    Provide us your contact detailsone of our product experts will contact you to discuss your needs or schedule a demonstration at a time that suits

    Product selected: Model #







      *Demonstrations can only be scheduled within the UAE

      Sign up to stay in the know-how of our latest products, updates, special offers, and more.

      • Subscription Form