  • FLUKE 724 Temperature Calibrator

    # 724

    • 2-channel display; Source/Stimulate 7 RTD; 10 Thermocouples; Volts; Ohms.
    • A thermocouple (TC) input/output terminal and internal isothermal block with automatic reference-junction temperature compensation.
    • Easy to access battery door for quick changes

    Fluke 724 Temperature Calibrator offers everything you need to troubleshoot and calibrate temperature

     

    The Fluke 724 is powerful yet easy-to-use temperature calibrator that sources and measures 10 thermocouple types, and 7 RTD types, plus volts and ohms. It also measures mA while supplying loop power. You can use it to test and calibrate almost any temperature instrument so you only have to carry one tool to expertly test all the temperature sensors and transmitters in your plant.

     

    The Fluke 724 even handles high-speed pulsed RTD circuits and provides loop power. The dual-line measure/source display lets you source temperature and view loop current at the same time. And with its simple, “no menus controls, you’ll be able to get all your testing done faster.

     

    Other useful features:

    • A bright backlight to enable you to work in poor light
    • Large battery capacity with four AA alkaline batteries
    • Easy to access battery door for quick changes

     

    Other useful features:

    • Performs fast linearity tests with 25% and 100% steps
    • Executes remote tests with auto step and auto ramp
    • Powers transmitters during test using loop power supply with simultaneous mA measurement
    • Features a compact, streamlined shape that makes it easy to carry
    • Offers a rugged, reliable design that stands up to field use

     

    Key features

    • A powerful, easy-to-use calibrator that measures and sources functions to test and calibrate most temperature instruments
    • Displays input and output simultaneously on the easy-to-read dual display
    • Measures RTDs, thermocouples, ohms, and volts to test sensors and transmitters
    • Source/simulates thermocouples, RTDs, volts, and ohms to calibrate transmitters
    Measurement Accuracy
    Voltage DC30.000 V0.02% + 2 counts (upper display)
    20.000 V0.02% + 2 counts (lower display)
    100.00 mV0.02% + 2 counts
    -10.00 mV to 75.00 mV0.025% + 1 count (via TC connector)
    Current DC24.000 mA0.02% + 2 counts
    Resistance0.0 to 400.0 Ω0.1 Ω (4-wire), 0.15 Ω (2- and 3-wire)
    401 to 1500 Ω0.5 Ω (4-wire), 1 Ω (2- and 3-wire)
    1500 to 3200 Ω1 Ω (4-wire), 1.5 Ω (2- and 3-wire)
    Source Accuracy
    Voltage DC100.00 mV0.02% + 2 counts
    10.000 V0.02% + 2 counts
    -10.00 mV to 75.00 mV0.025 % + 1 count (via TC connector)
    Resistance15.0 to 400.0 Ω0.15 Ω (exc. current 0.15 to 0.5 mA), 0.1 Ω (exc. current 0.5 to 2 mA)
    401 to 1500 Ω0.5 Ω (excitation current 0.05 to 0.8 mA)
    1500 to 3200 Ω1 Ω (excitation current 0.05 to 0.4 mA)
    RTDs and Thermocouples
    Measure accuracyNI-1200.2°C
    PT-100 (385)0.33°C
    PT-100 (393)0.3°C
    PT-100 (JIS)0.3°C
    PT-200 (385)0.2°C
    PT-500 (385)0.3°C
    PT-1000 (385)0.2°C
    Resolution0.1°C
    J0.7°C
    K0.8°C
    T0.8°C
    E0.7°C
    R1.8°C
    S1.5°C
    B1.4°C
    L0.7°C
    U0.75°C
    N0.9°C
    ResolutionJ, K, T, E, L, N, U: 0.1°C, 0.1°F B, R, S: 1°C, 1°F
    XK0.6°C
    BP1.2°C
    Source accuracyNI-1200.2°C
    PT-100 (385)0.33°C
    PT-100 (393)0.3°C
    PT-100 (JIS)0.3°C
    PT-200 (385)0.2°C
    PT-500 (385)0.3°C
    PT-1000 (385)0.2°C
    Resolution0.1°C
    Accuracy stated for 4-wire measurement.
    J0.7°C
    K0.8°C
    T0.8°C
    E0.7°C
    R1.4°C
    S1.5°C
    B1.4°C
    L0.7°C
    U0.75°C
    N0.9°C
    ResolutionJ, K, T, E, L, N, U: 0.1°C, B, R, S: 1°C
    XK0.6°C
    BP1.2°C
    Specifications
    Ramp functionsSource functionsVoltage, current, resistance, frequency, temperature
    RampsSlow ramp, Fast ramp, 25% step-ramp
    Loop power functionVoltage24 V
    Accuracy10%
    Maximum current22 mA, short circuit protected
    Step functionsSource functionsVoltage, current, resistance, frequency, temperature
    Steps25% of range, 100% of range
    Environmental Specifications
    Operating temperature-10°C to 55°C
    Storage temperature-20°C to 71°C
    Humidity (without condensation)90%10°C to 30°C
    75%30°C to 40°C
    45%40°C to 50°C
    35%50°C to 55°C
    Safety Specifications
    Safety ratingCSA C22.2 No. 1010.1:1992
    EMCEN50082-1:1992 and EN55022:1994 Class B
    Mechanical and General Specifications
    Size96 x 200 x 47 mm
    Weight650 g
    BatteriesFour AA alkaline batteries
    WarrantyThree years
    Battery life25 hours typical
    Shock and vibrationRandom, 2 G, 5-500 Hz
    • AC70A Test Clips
    • One pair of stackable test leads
    • TL75 Test Leads
    • CE and CSA Markings
    • Manuals in English, French, German, Spanish, Italian, Portugese, Korean, Chinese and Japanese
    • Users manuals on CD-ROM