Add products to your Toolbox to save it for requesting a quote while you keep browsing for other products to complete your list.
# 1587MDT
AC Voltage Measurements | |
Range | 600 mV 6 V 60 V 600 V 1000 V |
Resolution | 0.1 mV 0.001 V 0.01 V 0.1 V 1 V |
50 to 60 Hz ±(% of Rdg + counts) | ±(1% + 3) ±(1% + 3) ±(1% + 3) ±(1% + 3) ±(2% + 3) |
60 to 5000 Hz ±(% of Rdg + counts) | ±(2% + 3) ±(2% + 3) ±(2% + 3) ±(2% + 3)1 ±(2% + 3)1 |
Low-Pass Filter Voltage | |
Range | 600 mV 6 V 60 V 600 V 1000 V |
Resolution | 0.1 mV 0.001 V 0.01 V 0.1 V 1 V |
50 to 60 Hz ±(% of Rdg + counts) | ±(1% + 3) ±(1% + 3) ±(1% + 3) ±(1% + 3) ±(2% + 3) |
60 to 400 Hz ±(% of Rdg + counts) | ±(2% + 3) – (6% – 3) ±(2% + 3) – (6% – 3) ±(2% + 3) – (6% – 3) ±(2% + 3) – (6% – 3) ±(2% + 3) – (6% – 3) |
DC Voltage Measurement | |
Range | 6 V dc 60 V dc 600 V dc 1000 V dc |
Resolution | 0.001 V 0.01 V 0.1 V 1 V |
Accuracy ±(% of Rdg + Counts) | ±(0.09% + 2) ±(0.09% + 2) ±(0.09% + 2) ±(0.09% + 2) |
Input Impedance | 10 MΩ (nominal), <100 pF |
Nominal Mode Rejection Ratio | >60 dB at 50 or 60 Hz |
Common Mode Rejection Ratio | >120 dB at dc, 50 or 60 Hz (1 k unbalance) |
DC Millivolts Measurement | |
Range | 600 mVdc |
Resolution | 0.1 mV |
Accuracy ±(% of Rdg + Counts) | ±(0.1 + 1) |
DC and AC Current Measurement | |
Range | 400 mA |
Resolution | 0.1 mA |
Accuracy ±(% of Rdg+Counts) | ±(1.5% + 2)1 |
Burden Voltage (Typical) | 2 mV/mA |
Range | 60 mA |
Resolution | 0.01 mA |
Accuracy ±(% of Rdg+Counts) | ±(1.5% + 2)1 |
Burden Voltage (Typical) | 2 mV/mA |
DC | |
Range | 400 mA |
Resolution | 0.1 mA |
Accuracy ±(% of Rdg+Counts) | ±(0.2% + 2) |
Burden Voltage (Typical) | 2 mV/mA |
Range | 60 mA |
Resolution | 0.01 mA |
Accuracy ±(% of Rdg+Counts) | ±(0.2% + 2) |
Burden Voltage (Typical) | 2 mV/mA |
Overload | 600 mA for 2 minutes maximum |
Fuse Protection for mA Input | 0.44 mA, 1000 V, IR 10 kA |
AC Conversion | Inputs are ac-coupled and calibrated to the rms value of sine wave input |
Ohms Measurement | |
Range | 600 Ω 6 kΩ 60 kΩ 600 kΩ 6 MΩ 50 MΩ |
Resolution | 0.1 Ω 0.001 kΩ 0.01 kΩ 0.1 kΩ 0.001 MΩ 0.01 MΩ |
Accuracy +(% of Rdg+Counts)1 | ±(0.9% + 2) ±(0.9% + 2) ±(0.9% + 2) ±(0.9% + 2) ±(0.9% + 2) ±(1.5% + 3) |
Overload Protection | 1000 rms or dc |
Open Circuit Test Voltage | <8 V dc |
Short Circuit Current | <1.1 mA |
Diode Test | |
Diode Test Indication | Display voltage drop: 0.6 V at1.0 mA nominal test current |
Accuracy | ±(2% + 3) |
Continuity Test | |
Continuity Indication | Continuous audible tone for testresistance below 25 Ω and off above 100 Ω Maximum reading: 1000 Ω |
Open Circuit Voltage | <8.0 V |
Short Circuit Current | 1.0 mA typical |
Overload Protection | 1000 V rms |
Response Time | >1 m sec |
Frequency Measurement | |
Range | 99.99 Hz 999.9 Hz 9.999 kHz 99.99 kHz |
Resolution | 0.01 Hz 0.1 Hz 0.001 kHz 0.01 kHz |
Accuracy ±(% of Rdg+Counts) | ±(0.1% + 1) ±(0.1% + 1) ±(0.1% + 1) ±(0.1% + 1) |
Frequency Counter Sensitivity | |
600.0 mV ac | V ac Sensitivity (RMS Sine Wave)1 5 Hz to 20 kHz: 100.0 mV V ac Sensitivity (RMS Sine Wave)1 20 to 100 kHz: 150.0 mV DC Trigger Levels¹ to 20 kHz2: NA |
6.0 V | V ac Sensitivity (RMS Sine Wave)1 5 Hz to 20 kHz: 1.0 V V ac Sensitivity (RMS Sine Wave)1 20 to 100 kHz: 1.5 V DC Trigger Levels¹ to 20 kHz2: -400.0 mV and 2.5 V |
60.0 V | V ac Sensitivity (RMS Sine Wave)1 5 Hz to 20 kHz: 10.0 V V ac Sensitivity (RMS Sine Wave)1 20 to 100 kHz: 36.0 V DC Trigger Levels¹ to 20 kHz2: 1.2 V and 4.0 V |
600.0 V | V ac Sensitivity (RMS Sine Wave)1 5 Hz to 20 kHz: 100.0 V V ac Sensitivity (RMS Sine Wave)1 20 to 100 kHz: NA DC Trigger Levels¹ to 20 kHz2: 12.0 V and 40.0 V |
1000.0 V | V ac Sensitivity (RMS Sine Wave)1 5 Hz to 20 kHz: 300.0 V V ac Sensitivity (RMS Sine Wave)1 20 to 100 kHz: NA DC Trigger Levels¹ to 20 kHz2: 12.0 V and 40.0 V |
Capacitance | |
Range | 1000 nF 10.00 µF 100.0 µF 9999 µF |
Resolution | 1 nF 0.01 µF 0.1 µF 1 µF |
Accuracy ±(% of Rdg+Counts) | ±(1.2% + 2) ±(1.2% + 2) ±(1.2% ± 90 counts) ±(1.2% ± 90 counts) |
Temperature Measurement | |
Range | -40 to 998°F (-40 to 537°C) |
Resolution | 0.1°F (0.1°C) |
Accuracy ±(% of Rdg+Counts)1 | ±(1% + 10 counts) ±(1% + 18 counts) |
Insulation Specifications | |
Measurement Range | 0.01 MΩ to 2 GΩ |
Test Voltages | 50, 100, 250, 500, 1000 V |
Test Voltage Accuracy | 20%, 0% |
Short-Circuit Test Current | 1 mA nominal |
Auto Discharge | Discharge time <0.5 second for C=1 µF or less |
Live Circuit Detection | Inhibit test if terminal voltage >30 V prior to initialization of test |
Maximum Capacitive Load | Operable with up to 1 µF load |
Output Voltage | |
50 V (0% to +20%) | Display range: 0.01 to 6.00 MΩ Resolution: 0.01 MΩ Test current: 1 mA at 50 kΩ Resistance accuracy ±(% of Rdg + Counts): ±(3% + 5 counts) Display range: 6.0 to 50.0 MΩ Resolution: 0.1 MΩ Test current: 1 mA at 50 kΩ Resistance accuracy ±(% of Rdg + Counts): ±(3% + 5 counts) |
100 V (0% to +20%) | Display range: 0.01 to 6.00 MΩ Resolution: 0.01 MΩ Test current: 1 mA at 100 kΩ Resistance accuracy ±(% of Rdg + Counts): ±(3% + 5 counts) Display range: 6.0 to 60.0 MΩ Resolution: 0.1 MΩ Test current: 1 mA at 100 kΩ Resistance accuracy ±(% of Rdg + Counts): ±(3% + 5 counts) Display range: 6.0 to 100.0 MΩ Resolution: 0.1 MΩ Test current: 1 mA at 100 kΩ Resistance accuracy ±(% of Rdg + Counts): ±(3% + 5 counts) |
250 V (0% to +20%) | Display range: 0.1 to 60.0 MΩ Resolution: 0.1 MΩ Test current: 1 mA at 250 kΩ Resistance accuracy ±(% of Rdg + Counts): ±(1.5% + 5 counts) Display range: 60 to 250 MΩ Resolution: 1 MΩ Test current: 1 mA at 250 kΩ Resistance accuracy ±(% of Rdg + Counts): ±(1.5% + 5 counts) |
500 V (0% to +20%) | Display range: 0.1 to 60.0 MΩ Resolution: 0.1 MΩ Test current: 1 mA at 500 kΩ Resistance accuracy ±(% of Rdg + Counts): ±(1.5% + 5 counts) Display range: 60 to 500 MΩ Resolution: 1 MΩ Test current: 1 mA at 250 kΩ Resistance accuracy ±(% of Rdg + Counts): ±(1.5% + 5 counts) |
1000 V (0% to +20%) | Display range: 0.1 to 60.0 MΩ Resolution: 0.1 MΩ Test current: 1 mA at 1 MΩ Resistance accuracy ±(% of Rdg + Counts): ±(1.5% + 5 counts) Display range: 60 to 600 MΩ Resolution: 1 MΩ Test current: 1 mA at 1 MΩ Resistance accuracy ±(% of Rdg + Counts): ±(1.5% + 5 counts) Display range: 0.6 to 2.0 GΩ Resolution: 100 MΩ Test current: 1 mA at 1 MΩ Resistance accuracy ±(% of Rdg + Counts): ±(10% + 3 counts) |
Product selected: Model #